9-86 Upgrading Your Server
5.
Push the DIMM straight into the socket.
NOTE:
Make sure of the orientation of the DIMM. The terminal side
of the DIMM has key and key slot to prevent incorrect insertion.
If the DIMM is inserted into the DIMM socket, the lever is automatically closed.
IMPORTANT:
Install a pair of DIMMs at a time. In addition, use a
set of memory devices with the same specification. The specification of
a memory device is described on the label put on the DIMM.
6.
Install the remove components.
7.
Turn on the power of the server. Then make sure that any error message does not appear
in POST.
If an error message appears, write down the message and review the error message list in
Chapter 8.
8.
Start SETUP to select [Advanced]
→
[Memory Configuration] on menus. Then make sure
that the status of the additional DIMM is set to "Normal" (see Chapter 4).
9.
Set [Reset Configuration Data] on the [Advanced] menu to "Yes".
This is required to update the hardware configuration. See Chapter 4 for details.
10.
When the Windows operating system is used, set the paging file size to the recommended
value or larger.
Installed memory capacity × 1.5 (See Chapter 5.)
Содержание N8100-1417F
Страница 16: ...x This page is intentionally left blank...
Страница 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Страница 108: ...4 40 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information...
Страница 119: ...Configuring Your Server 4 51 Use this menu to define several physical drives PD as a disk group DG...
Страница 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed...
Страница 195: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 220: ...7 12 Maintenance This page is intentionally left blank...
Страница 300: ...9 42 Upgrading Your Server Removal Remove the HDD cage in the reverse procedure of the installation...
Страница 316: ...9 58 Upgrading Your Server Removal Remove the 5 25 inch device in the reverse procedure of the installation...
Страница 352: ...9 94 Upgrading Your Server This page is intentionally left blank...
Страница 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Страница 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank...
Страница 362: ...A 2 Specifications This page is intentionally left blank...
Страница 370: ...C 2 IRQ This page is intentionally left blank...
Страница 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Страница 430: ...G 4 Product Configuration Record Table This page is intentionally left blank...