background image

QuickSpecs  

HP ProLiant BL660c Gen9 Server Blade 

Overview 

 

 

 

c04543743 - DA - 15185 Worldwide - Version 5 - September 28, 2015 

Page 1 

 

 

HP ProLiant BL660c Gen9 Server Blade 

 

 

HP ProLiant BL660c Gen9 Server Blade – Internal View 

1.  Four hot-plug drive bays 

7. 

Micro-SD slot 

2.  M.2 Option Connector 

8. 

FlexibleLOM adapters 

3.  HP BLc 12W Smart Storage Battery connector 

9. 

Two or Four Intel® Xeon® E5-4600 v3 family processors 

4.  HP Smart Array P246br Controller with 1GB FBWC 

10. 

Thirty two DDR4 DIMM slots (8 per processor) 

5.  iLO Management Engine 

11. 

USB 3.0 and TPM 

6.  Mezzanine Slots (x16 PCI 3.0) 

12. 

Embedded SATA Connectors 
 

 

What's New 
 

 

Flexible Controller Options 

 

Support for 2133MHz  DDR4 memory 

 

Support for 12Gb SAS internal hard drives and 12Gb SAS storage controller offerings 

 

4 SFF drive bays 

 

Support for the Intel E5-4600 v3 Product Family 

Summary of Contents for ProLiant BL660c Gen9

Page 1: ...c 12W Smart Storage Battery connector 9 Two or Four Intel Xeon E5 4600 v3 family processors 4 HP Smart Array P246br Controller with 1GB FBWC 10 Thirty two DDR4 DIMM slots 8 per processor 5 iLO Management Engine 11 USB 3 0 and TPM 6 Mezzanine Slots x16 PCI 3 0 12 Embedded SATA Connectors What s New Flexible Controller Options Support for 2133MHz DDR4 memory Support for 12Gb SAS internal hard drives...

Page 2: ...please see http www hp com go spp download NOTE For the Standard Features shipped in the Factory Integrated Models please see the Configuration Information Factory Integrated Models section Processor Two or four of the following depending on Model E5 4600 v3 series Processors HP BL660c Gen9 Intel Xeon E5 4610v3 1 7GHz 10 core 25MB 105W HP BL660c Gen9 Intel Xeon E5 4620v3 2 0GHz 10 core 25MB 105W H...

Page 3: ... at 1 2V Maximum RDIMM 1TB 32 x 32GB up to 2133MHz at 1 2V NOTE HP memory from previous generation servers DDR3 is not compatible with this server HP SmartMemory is required to realize the memory performance improvements and enhanced functionality listed in this document for Gen9 For additional information please see the HP SmartMemory QuickSpecs at http www8 hp com h20195 v2 GetHTML aspx docname ...

Page 4: ... server interconnectivity I O accelerator mezzanine options for high transaction rate local storage HP Server ROM HP ROM read only memory is now digitally signed using HP s Corporate Signing Service This signature is verified before the flash process starts reducing accidental programming and preventing malicious efforts to corrupt system ROM HP ROM provides for essential initialization and valida...

Page 5: ...ntroller with 1GB Flash Backed Write Cache FBWC supporting RAID 0 1 and 5 NOTE The HP Smart Array P246br and the HP B140i chipset SATA Support four 4 small form factor SFF hot plug drive bays Maximum Internal Storage One of the following depending on Model Hot Plug SFF SAS 4 8TB 4 x 1 2TB Hot Plug SFF SATA 8 0TB 4 x 2 0TB Hot Plug SFF SAS SSD 6 4TB 4 x 1 6TB Hot Plug SFF SATA SSD 7 68TB 4 x 1 92TB...

Page 6: ...rack enclosure is 6U high and holds up to eight 4 HP ProLiant BL660c Gen9 servers plugged horizontally Server blades interconnect modules power supplies fans and redundant Onboard Administrator modules are all designed to fit into the c3000 and c7000 enclosures NOTE For additional enclosure information please see http h18004 www1 hp com products blades components enclosures c class index html Grap...

Page 7: ...or http www hp com go powershell HP RESTful Interface Tool HP RESTful API tool is a scripting tool to provision servers using RESTful API Interface to discover and deploy servers at scale Learn more at http www hp com go restfulapi HP iLO Mobile Application Enables the ability to access deploy and manage your server anytime from anywhere from select smartphones and mobile devices For additional in...

Page 8: ...res hardware errors such as system bus memory ECC parity and cache and improves service time Intel QPI Protocol Protection allows detection of data errors using a checksum of 8 bits Core Disable for FRB fault resilient boot allows a system to power on despite a failing core pair It uses BIST built in self test results to detect a failure and disables the target core pair upon subsequent boot Serve...

Page 9: ...ar warranty refer to specific hard drive QuickSpecs for details NOTE Server warranty includes 3 year Parts 3 year Labor 3 year on site support Warranty repairs may be accomplished through the use of Customer Self Repair CSR parts These parts fall into two categories 1 Mandatory CSR parts are designed for easy replacement A travel and labor charge will result when customers decline to replace a Man...

Page 10: ...es the full integrated remote console virtual keyboard video and mouse KVM multi user collaboration console record and replay and GUI based and scripted virtual media and virtual folders You can also activate the enhanced security and power management functionality Learn more about HP iLO Advanced at http www hp com go iloadvanced Server Management HP Insight Control HP Insight Control lets you de...

Page 11: ...cost effectively protect you against disaster and ensure business continuity Data Archive and Migration Software HP s storage software enables you to comply with data retention and retrieval requirements improve application performance and reduce costs by efficiently migrating infrequently accessed or less valuable data to lower cost storage Storage Resource Management Software SRM HP s storage re...

Page 12: ...onfiguration customization integration and deployment services for HP servers and storage products Customers can choose how their factory solutions are built tested integrated shipped and deployed Factory Express offers service packages for simple configuration racking installation complex configuration and design services as well as individual factory services such as image loading asset tagging ...

Page 13: ...s troubleshooting and shortens time to resolution with one call for hardware or software questions http h20195 www2 hp com V2 GetDocument aspx docname 4AA5 3259ENW cc us lc en Standard Support recommendation HP Proactive Care 24x7 coverage three year Care Pack Service This service helps prevent problems and stabilize IT by utilizing secure real time predictive analytics and proactive consultations...

Page 14: ... Materials HP will provide HP supported replacement parts and materials necessary to maintain the covered hardware product in operating condition including parts and materials for available and recommended engineering improvements Parts and components that have reached their maximum supported lifetime and or the maximum usage limitations as set forth in the manufacturer s operating manual product ...

Page 15: ...4620 v3 2 0GHz 10 core 25MB 8 0GT s QPI 105W DDR4 1866 HT Turbo Cache Memory 25MB 1x25MB Level 3 cache Memory 128GB 8x 16GB PC4 2133P R DDR4 2133 Registered DIMMS at 1 2V NOTE Total of 32 DIMM slots Network Controller 2 HP FlexFabric 10Gb 2 port 536FLB FlexibleLOM Storage Controller HP Smart Array P246br Controller with 1GB FBWC RAID 0 1 5 Hard Drive None ship standard Supports up to four 4 HP hot...

Page 16: ...ormation on CTO product offerings and requirements NOTE Configure to order server blades must start with a CTO Server Blade NOTE FIO indicates that this option is only available as a factory installable option NOTE All Factory Integrated Models will be populated with sufficient hard drive blanks based on the number of initial hard drives ordered with the server Step 1 Base Server Blade Configurati...

Page 17: ... power SKUs NOTE All processors within the server must be identical HP Memory NOTE HP memory from previous generation servers DDR3 is not compatible with this server HP SmartMemory is required to realize the memory performance improvements and enhanced functionality listed in this document for Gen9 For additional information please see the HP SmartMemory QuickSpecs at http www8 hp com h20195 v2 Ge...

Page 18: ...le Smart Array B140i Setting 784308 B21 NOTE The HP Smart Array B140i Controller chipset SATA comes standard with the HP BL660c Gen9 10Gb 20Gb FLB CTO Blade If the HP Smart Array P246br controller is not chosen SATA cables will be provided to support SATA devices for the four internal drives If RAID is required when using the B140i please choose HP FIO B140i RAID Enable Kit BIOS Setting 784308 B21...

Page 19: ...ctory Integrated Models c04543743 DA 15185 Worldwide Version 5 September 28 2015 Page 19 NOTE For optimal cooling and system performance the BL660c Gen9 Server Blade requires the c7000 enclosure to be configured with 10 fans and the c3000 enclosure to be configured with 6 fans ...

Page 20: ...et 1Gb 4 port 366M Adapter NOTE Please see QuickSpecs for technical specifications and additional information at http h18000 www1 hp com products quickspecs 14335_div 14335_div html 615729 B21 FlexibleLOM Adapters NOTE The server supports a maximum of two FlexibleLOMs that are installed in the FlexibleLOM connectors NOTE For a single FlexibleLOM Factory Integrated Model configuration select the op...

Page 21: ... www8 hp com h20195 v2 GetDocument aspx docname c04126962 710608 B21 HP LPe1205A 8Gb Fibre Channel Host Bus Adapter NOTE Please see QuickSpecs for technical specifications and additional information at http www8 hp com h20195 v2 GetDocument aspx docname c04163733 659818 B21 HP QMH2572 8Gb Fibre Channel Host Bus Adapter NOTE Please see QuickSpecs for technical specifications and additional informat...

Page 22: ...Tool Home Legal HP SmartMemory Registered DIMMs RDIMMs E5 4600 v3 series Processors HP 8GB 1x8GB Dual Rank x8 DDR4 2133 CAS 15 15 15 Registered Memory Kit 759934 B21 HP 8GB 1x8GB Single Rank x4 DDR4 2133 CAS 15 15 15 Registered Memory Kit 726718 B21 HP 16GB 1x16GB Dual Rank x4 DDR4 2133 CAS 15 15 15 Registered Memory Kit 726719 B21 HP 32GB 1x32GB Dual Rank x4 DDR4 2133 CAS 15 15 15 Registered Memo...

Page 23: ...83 B21 HP 450GB 6G SAS 10K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652572 B21 HP 300GB 6G SAS 10K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652564 B21 HP 300GB 6G SAS 15K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652611 B21 HP 146GB 6G SAS 15K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652605 B21 SAS Hot Plug SmartDrive SFF 2 5 inch Midline Driv...

Page 24: ...Gb SATA 2 5in RI PLP SC SSD 804575 B21 6G SATA Hot Plug MU 3 SFF 2 5 inch SC Solid State Drives HP 1 92TB 6G SATA MU 3 SFF SC SSD 817011 B21 HP 960GB 6G SATA MU 3 SFF SC SSD 816995 B21 HP 480GB 6G SATA MU 3 SFF SC SSD 816985 B21 HP 240GB 6G SATA MU 3 SFF SC SSD 816975 B21 HP 120GB 6Gb SATA 2 5 MU PLP SC S2 SSD 816965 B21 6G SATA Hot Plug RI 3 SFF 2 5 inch SC Solid State Drives HP 3 84TB 6G SATA RI...

Page 25: ...68 B21 HP 800GB 12G SAS Mainstream Endurance SFF 2 5 in ENT Mainstream SC 3yr Wty H2 Solid State Drive 779172 B21 HP 1 6TB 12G SAS Mainstream Endurance SFF 2 5 in ENT Mainstream SC 3yr Wty H2 Solid State Drive 779176 B21 12G SAS VE SFF 2 5 inch SC EV Solid State Drives HP 1 6TB 12G SAS Value Endurance SFF 2 5 in SC Enterprise Value 3yr Wty Solid State Drive 762263 B21 HP 800GB 12G SAS Value Endura...

Page 26: ...Specs at http www8 hp com h20195 v2 GetHTML aspx docname c04123391 HP iLO Advanced License HP Integrated Lights Out iLO Advanced for ProLiant BladeSystem Remote Management HP iLO Advanced for BladeSystem including 3yr 24x7 Technical Support and Updates E LTU E6U63ABE HP iLO Advanced Blade 1 Server License with 3yr 24x7 Tech Support and Updates BD502A HP iLO Advanced for BladeSystem including 1yr 2...

Page 27: ...ght Cluster Management Utility Media NOTE For additional license kits please see the QuickSpecs at http h18004 www1 hp com products quickspecs 12612_div 12612_div html BD477A HP I O Accelerator Options HP 1 2TB Read Intensive Mezzanine PCIe Workload Accelerator for BladeSystem c Class 794603 B21 HP 1 6TB Read Intensive Mezzanine PCIe Workload Accelerator for BladeSystem c Class 794605 B21 HP Secur...

Page 28: ...be installed in any mezzanine slot if operated in any other mode HP InfiniBand FDR 2 port 545M Adapter 702213 B21 HP Flash Media Kits for USB Drives HP Flash Media Kits for USB Drives HP Enterprise Mainstream Flash Media Kits for Memory Cards HP 8GB USB Enterprise Mainstream Flash Media Drive Key Kit 737953 B21 HP 8GB microSD Enterprise Mainstream Flash Media Kit 726116 B21 HP 32GB microSD Enterpr...

Page 29: ...in any order the server will select a common optimal speed The maximum memory speed is a function of the memory type memory configuration and processor model The maximum memory capacity is a function of the memory type and number of installed processors HP memory from previous generation servers is not compatible with the BL660c Gen9 Server Blade To realize the performance memory capabilities list...

Page 30: ...GB 4x 16GB 256GB 4x 16GB 12x 16GB 1TB 16x 64GB Intel Xeon E5 2650 v3 E5 2640 v3 32GB 2x 16GB 256GB 2x 16GB 14x 16GB 1TB 16x 64GB Intel Xeon E5 2620 v3 E5 2609 v3 16GB 2x 8GB 240GB 2x 8GB 14x 16GB 1TB 16x 64GB NOTE Support for 64GB LRDIMMs and 32GB RDIMMs to be available by early 2015 NOTE Capacity references are rounded to the common gigabyte GB values 2GB 2 048MB 4GB 4 096MB 8GB 8 192MB 16GB 16 3...

Page 31: ...mory speed may run at 2133MHz 1866MHz or 1600MHz Please see Memory Population Table or the Online Memory Configuration Tool at http h22195 www2 hp com MemoryTool Home Legal HP SmartMemory Registered DIMMs RDIMMs Registered DIMMs RDIMMs E5 4600 v3 series Processors HP 8GB 1x8GB Dual Rank x8 DDR4 2133 CAS 15 15 15 Registered Memory Kit 759934 B21 HP 8GB 1x8GB Single Rank x4 DDR4 2133 CAS 15 15 15 Re...

Page 32: ...QuickSpecs HP ProLiant BL660c Gen9 Server Blade Storage c04543743 DA 15185 Worldwide Version 5 September 28 2015 Page 32 ...

Page 33: ...the BL660c Gen9 Server Blade requires the c7000 enclosure to be configured with 10 fans and the c3000 enclosure to be configured with 6 fans System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1 000 ft above sea level to a maximum of 3 050 m 10 000 ft no direct sustained sunlight Maximum rate of change is 10 C hr ...

Page 34: ...Cache Memory 1GB flash backed write cache FBWC cache standard Logical Drives Supported 64 with included 1GB cache Host Memory Addressing 64 bit supporting servers memory space greater than 4GB RAID Support RAID 1 mirroring RAID 0 striping RAID 5 RAID 10 Other Upgradeable firmware with recovery ROM Online drive flash with SAS drives HP Dynamic Smart Array B140i Controller Disk Drive Interface 6Gb s...

Page 35: ... Up to 40Gb s bi directional near line rate throughput Hardware acceleration and offloads for stateless TCP IP TCP Offload Engine TOE Improved small packet performance Support for Preboot eXecution Environment PXE Integrated PHY and MAC Supports for SR IOV Support for Network Partitioning NPAR HP FlexFabric 20Gb 2 port 650FLB FlexibleLOM Type Integrated dual port KR2 20Gb FlexibleLOM with FlexFabr...

Page 36: ...L Support for Preboot eXecution Environment PXE Support for Microsoft Windows SMB Direct Optimized host virtualization density with SR IOV support Environment friendly Products and Approach End of life Management and Recycling Hewlett Packard offers end of life HP product return trade in and recycling programs in many geographic areas For trade in information please go to http www hp com go green ...

Page 37: ...u added in Core Options Section 779176 B21 19 Jun 2015 From Version 1 to 2 Changed Information in Additional Options and Configuration information Factory Integrated Models section were updated Removed Obsolete Sku removed 741146 B21 Added Skus were added in Additional Options Section U8LQ2E U8LQ3E U8LQ5E U8LQ6E 659818 B21 651281 B21 Copyright 2015 Hewlett Packard Development Company L P The infor...