Troubleshooting 8-7
Error
code
Error message
Recommended Action
8100
Memory Error detected in DIMM group #1.
8101
Memory Error detected in DIMM group #2.
8102
Memory Error detected in DIMM group #3.
8103
Memory Error detected in DIMM group #4.
8104
Memory Error detected in DIMM group #5.
8105
Memory Error detected in DIMM group #6.
Contact your service representative to
replace the DIMM in the relevant group.
8160
Mismatch Processor speed detected on
Processor 1.
8161
Mismatch Processor speed detected on
Processor 2.
Contact your service representative.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core Hardware failure.
0B83
BMC 1BF or 0BF check failed.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B8A
BMC SEL area full
Clear the system event logs by using the
BIOS SETUP utility (see Chapter 4).
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B92
Internal Use Area of BMC FRU corrupted.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
0B93
BMC SDR Repository empty.
Turn off the power once and then on again
to restart the server. If the error cannot be
corrected, contact your service
representative.
0B94
IPMB signal lines do not respond.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
0B95
BMC FRU device failure.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B9A
Management controller not responding.
Update the RMC firmware. If the error
cannot be corrected, contact your service
representative.
Содержание N8100- 1241F
Страница 68: ...2 36 General Description This page is intentionally left blank...
Страница 194: ...6 26 Installing and Using Utilities This page is intentionally left blank...
Страница 206: ...7 12 Maintenance This page is intentionally left blank...
Страница 296: ...9 56 Upgrading Your Server This page is intentionally left blank...
Страница 308: ...C 2 IRQ This page is intentionally left blank...
Страница 354: ...E 24 Installing Windows Server 2003 This page is intentionally left blank...
Страница 358: ...F 4 Product Configuration Record Table This page is intentionally left blank...