Troubleshooting 8-11
On-screen message
Description
Action
Memory C-Err XX
A correctable error frequently occurs
in DIMM #XX.
Memory U-Err XX
An uncorrectable error has occurred in
DIMM #XX.
PCI Bus PERR XX
A PERR has occurred in the PCI bus
XX.
PCI Bus SERR XX
A SERR has occurred in the PCI bus
XX.
Contact your service
representative.
Prepare To Boot
POST completes normally.
This is not an error.
Messages displayed on lower line (BMC message)
When the following messages are displayed on the virtual LCD, restart your server by turning off
and on. If an error still occurred, contact your service representative for maintenance.
On-screen message
Description
240VA Power Down
Power supply failure occurred.
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5.0v Alm XX
BB +12v Alm XX
BB P_Vtt Alm XX
Voltage alarm occurred on the mother board.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
BB Temp1 Alm XX
Mother board thermal error occurred.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
DUMP Request !
Dump switch is pressed.
OS shutdown Alm
OS shutdown alarm occurred.
Power On Cnt Alm
Power supply failure occurred.
Power Unit 1 Alm
Power unit #1 Failure occurred.
Power Unit 2 Alm
Power unit #2 Failure occurred.
Proc Missing
Processor is not found.
Proc 1 T-Trip
Proc 2 T-Trip
Thermal Trip occurred on processor #1 or #2. The system is forcibly
turned off.
Proc1 Therm % XX
Proc2 Therm % XX
Processor #1 or #2 thermal error occurred.
XX=09: high temperature (fetal)
XX=07: high temperature (warning)
XX=02: low temperature (warning)
XX=00: low temperature (fetal)
Proc1 VccpAlm XX
Proc2 VccpAlm XX
Voltage alarm occurred on processor #1 or #2.
XX=09: high voltage (fetal)
XX=07: high voltage (warning)
XX=02: low voltage (warning)
XX=00: low voltage (fetal)
Processor 1 IERR
IERR occurred on processor #1 or #2.
Содержание N8100- 1241F
Страница 68: ...2 36 General Description This page is intentionally left blank...
Страница 194: ...6 26 Installing and Using Utilities This page is intentionally left blank...
Страница 206: ...7 12 Maintenance This page is intentionally left blank...
Страница 296: ...9 56 Upgrading Your Server This page is intentionally left blank...
Страница 308: ...C 2 IRQ This page is intentionally left blank...
Страница 354: ...E 24 Installing Windows Server 2003 This page is intentionally left blank...
Страница 358: ...F 4 Product Configuration Record Table This page is intentionally left blank...