8-42 Troubleshooting
Description
On-screen message
Recommended action
IO +3.3V AUX Alm 07
+3.3V AUX voltage warning (upper limit) occurred in I/O riser board.
IO +3.3V AUX Alm 00
+3.3V AUX voltage warning (lower limit) occurred in I/O riser board.
IO +1.8Vs Alm 07
+1.8Vs voltage warning (upper limit) occurred in I/O riser board.
IO +1.8Vs Alm 00
+1.8Vs voltage warning (lower limit) occurred in I/O riser board.
IO +1.2Vs Alm 07
+1.2Vs voltage warning (upper limit) occurred in I/O riser board.
IO +1.2Vs Alm 00
+1.2Vs voltage warning (lower limit) occurred in I/O riser board.
IO +1.0Vs Alm 07
+1.0Vs voltage warning (upper limit) occurred in I/O riser board.
IO +1.0Vs Alm 00
+1.0Vs voltage warning (lower limit) occurred in I/O riser board.
IO +12V Alm 07
+12V voltage warning (upper limit) occurred in I/O riser board.
IO +12V Alm 00
+12V voltage warning (lower limit) occurred in I/O riser board.
IO +5V Alm 07
+5V voltage warning (upper limit) occurred in I/O riser board.
IO +5V Alm 00
+5V voltage warning (lower limit) occurred in I/O riser board.
IO +3.3V Alm 07
+3.3V voltage warning (upper limit) occurred in I/O riser board.
IO +3.3V Alm 00
+3.3V voltage warning (lower limit) occurred in I/O riser board.
IO +1.5V Alm 07
+1.5V voltage warning (upper limit) occurred in I/O riser board.
IO +1.5V Alm 00
+1.5V voltage warning (lower limit) occurred in I/O riser board.
IO +1.0V Alm 07
+1.0V voltage warning (upper limit) occurred in I/O riser board.
IO +1.0V Alm 00
+1.0V voltage warning (lower limit) occurred in I/O riser board.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the I/O riser board.
If the same error persists, contact your service representative.
Battery Alm 07
Voltage warning (upper limit) occurred on Li-Ion battery.
Battery Alm 00
Voltage warning (lower limit) occurred on Li-Ion battery.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the Li-Ion battery on base board.
If the same error persists, contact your service representative.
FP Temp Alm 07
A high temperature warning occurred in front panel.
FP Temp Alm 00
A low temperature warning occurred in front panel.
BB Temp Alm 07
A high temperature warning occurred in base board.
BB Temp Alm 00
A low temperature warning occurred in base board.
Check if fans in the server work normally.
If the same error persists, contact your service representative.
SASBP Temp NCAlm
A temperature warning occurred in SAS riser board.
Содержание Express5800/R140a-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 238: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 247: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 260: ...6 22 Installing and Using Utilities This page is intentionally left blank ...
Страница 278: ...7 18 Maintenance This page is intentionally left blank ...
Страница 352: ...8 74 Troubleshooting This page is intentionally left blank ...
Страница 414: ...9 62 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 430: ...C 4 This page is intentionally left blank ...
Страница 457: ...Installing Windows Server 2008 D 27 4 Activate Windows The Windows activation is complete ...