Troubleshooting 8-23
Error
code
Error message
Recommended Action
82E0
DIMM #1 with error is enabled
82E1
DIMM #2 with error is enabled
82E2
DIMM #3 with error is enabled
82E3
DIMM #4 with error is enabled
82E4
DIMM #5 with error is enabled
82E5
DIMM #6 with error is enabled
82E6
DIMM #7 with error is enabled
82E7
DIMM #8 with error is enabled
82E8
DIMM #9 with error is enabled
82E9
DIMM #10 with error is enabled
82EA
DIMM #11 with error is enabled
82EB
DIMM #12 with error is enabled
82EC
DIMM #13 with error is enabled
82ED
DIMM #14 with error is enabled
82EE
DIMM #15 with error is enabled
82EF
DIMM #16 with error is enabled
82F0
DIMM #17 with error is enabled
82F1
DIMM #18 with error is enabled
82F2
DIMM #19 with error is enabled
82F3
DIMM #20 with error is enabled
82F4
DIMM #21 with error is enabled
82F5
DIMM #22 with error is enabled
82F6
DIMM #23 with error is enabled
82F7
DIMM #24 with error is enabled
82F8
DIMM #25 with error is enabled
82F9
DIMM #26 with error is enabled
82FA
DIMM #27 with error is enabled
82FB
DIMM #28 with error is enabled
82FC
DIMM #29 with error is enabled
82FD
DIMM #30 with error is enabled
DIMM numbers shown in error message are
as show below.
DIMM #1 to DIMM #8:
DIMM #1 to DIMM #8 on memory board A
DIMM #9 to DIMM #16:
DIMM #1 to DIMM #8 on memory board B
DIMM #17 to DIMM #24:
DIMM #1 to DIMM #8 on memory board C
DIMM #25 to DIMM #32:
DIMM #1 to DIMM #8 on memory board D
1. Run BIOS SETUP, select [Advanced] -
[Memory Configuration] - [Memory Retest] -
[Yes], then select [Exit] - [Exit Saving
Changes].
2. Check installation status of failed DIMM.
3. Replace the failed DIMM.
4. Replace the relevant memory board.
5. If the same error persists, contact your
service representative.
Note: The detailed error information can be
obtained by viewing the IPMI system
event log.
If the processor is replaced, restart the
server and run BIOS SETUP. Select
[Main] - [Processor Settings] -
[Processor Retest] - [Yes], then select
[Exit] - [Exit Saving Changes].
82FE
DIMM #31 with error is enabled
82FF
DIMM #32 with error is enabled
8400
Onboard PCIE#1 Link Failure
8401
Onboard PCIE#2 Link Failure
8402
Onboard PCIE#3 Link Failure
8403
Onboard PCIE#4 Link Failure
8404
Onboard PCIE#5 Link Failure
8405
Onboard PCIE#6 Link Failure
8406
Onboard PCIE#7 Link Failure
Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service representative.
Содержание Express5800/R140a-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 238: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 247: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 260: ...6 22 Installing and Using Utilities This page is intentionally left blank ...
Страница 278: ...7 18 Maintenance This page is intentionally left blank ...
Страница 352: ...8 74 Troubleshooting This page is intentionally left blank ...
Страница 414: ...9 62 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 430: ...C 4 This page is intentionally left blank ...
Страница 457: ...Installing Windows Server 2008 D 27 4 Activate Windows The Windows activation is complete ...