![background image](http://html1.mh-extra.com/html/nec/express5800-320la/express5800-320la_user-manual_3907234029.webp)
System Overview 1-15
CPU Modules
The server has two CPU modules that provide Dual Modular Redundancy (DMR). The
CPU modules are numbered 1 and 2, left to right as seen from the front of the system.
Each CPU module has two status indicators that are listed along with a description of
each in Table 1-3. Table 1-8 summarizes the features of a CPU module.
Table 1-8. Features of the CPU Module
Feature
Description
Upgradable
multiple processor
slots
Two processor sockets are available on the CPU board for one or two
processors.
Upgradable
memory
Four DIMM sockets on the CPU board. Can contain a minimum of 256 MB
up to a maximum of 2 GB of Synchronous Dynamic Random-Access
(SDRAM) system memory.
SMP
Supports two-way Symmetric Multiprocessing (SMP) when two processors
are installed.
Fan
Two integrated fans that provide cooling for both the CPU module and hard
disk drives.
The system runs identical applications in both CPU modules in lockstep. Thus, if one
CPU module fails, the second CPU module takes over the processing without any
interruption to the current application running on the system. Note that this type of
failure is transparent to the user.
In simplex mode the system is operating with only one CPU module and one PCI
module. Thus, the failure of one CPU module or one PCI module causes the whole
system to fail. A fault-tolerant system should not run in the simplex mode for any
longer than necessary for upgrading or repair.
Storage Bays
The server has a storage area containing six storage bays that support six hard disk
drives (three logical disks). The hard disk drives are CRUs, hot pluggable, and
redundant. The disk slots are physically numbered 1 – 6, left to right as seen from the
front of the system. The disk drives SCSI ID numbers are 0, 1, 2 for each group of
logical disk drives and the first mirrored pairs are physical drives 1 and 4 that contain
the boot software, as shown below.
Group 1
Group 2
SCSI ID 0
Disk #1
SCSI ID 1
Disk #2
SCSI ID 2
Disk #3
SCSI ID 0
Disk #4
SCSI ID 1
Disk #5
SCSI ID 2
Disk #6
Содержание Express5800 320La
Страница 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Страница 2: ...NEC...
Страница 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Страница 40: ...1 26 System Overview...
Страница 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Страница 60: ...2 20 Setting Up the System...
Страница 154: ...4 68 CRU Replacement and Server Upgrades...
Страница 185: ...A Technical Specifications Server Unit...
Страница 188: ...A 4 Technical Specifications...
Страница 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Страница 192: ...B 4 ROMPilot BIOS Error Codes...
Страница 202: ...10 Glossary...
Страница 205: ...xx...
Страница 206: ...456 01572 N00...