5-26
Problem Solving
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B22
CPUs are installed out of order CPU is faulty.
•
Replace the CPU.
0B24
DIMMs are installed out of
order
DIMM is faulty.
•
Replace the DIMM.
0B26
Invalid MAC Address detected FRB2 Timeout error
occurred at SetMAC, and
rewriting of MAC address
failed.
•
Replace the front panel board.
0B28
Unsupported Processor
detected on Processor 1
The processor (CPU) not
supported by this server is
installed in Processor 1.
•
Install the CPU appropriate to
the server.
0B29
Unsupported Processor
detected on Processor 2
The processor (CPU) not
supported by this server is
installed in Processor 2.
•
Install the CPU appropriate to
the server.
0B30
CPU FAN #1 Alarm occurred
0B31
CPU FAN #2 Alarm occurred
•
Dust obstructing the fan.
•
Fan is faulty.
•
CPU module board is
faulty.
•
Replace the fan.
•
Replace the CPU module
board.
•
Connect fan cable properly.
0B32
CPU FAN #3 Alarm occurred
•
Dust obstructing the fan.
•
Fan is faulty.
•
PCI module board is faulty.
•
Replace the fan.
•
Replace the PCI module
board.
•
Connect fan cable properly.
0B47
Missing date and time
synchronization
The date and time are
incorrect due to a
communication error
between BMCs.
•
Restart the system.
•
Re-set the date and time in
SETUP.
•
If the error persists, replace the
PCI module board.
0B70
The error occurred during
temperature sensor reading
•
SMBus device is faulty.
•
SMBus is faulty.
•
Replace the CPU/PCI module
or front panel board.
0B71
System temperature out of
Range
•
Fan is faulty.
•
CPU/PCI module board is
faulty.
•
Clean the fan.
•
Replace the fan.
•
Replace the PCI module
board.
0B80
BMC Memory Test Failed
0B81
BMC Firmware Code Area
CRC check failed
0B82
BMC core Hardware failure
0B83
BMC IBF or OBF check failed
BMC is faulty.
•
Replace the PCI module
board.
0B84
BMC issued Reset Command,
but failed System Reset
BMC Reset command is
disabled and failed to reset
the system.
•
Replace the PCI module
board.
0B90
BMC Platform Information
Area corrupted
0B91
BMC update firmware
corrupted
BMC is faulty.
0B92
Internal Use Area of BMC FRU
corrupted
•
SROM is faulty.
•
BMC is faulty.
•
Replace the PCI module
board.
Содержание Express5800 320La
Страница 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Страница 2: ...NEC...
Страница 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Страница 40: ...1 26 System Overview...
Страница 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Страница 60: ...2 20 Setting Up the System...
Страница 154: ...4 68 CRU Replacement and Server Upgrades...
Страница 185: ...A Technical Specifications Server Unit...
Страница 188: ...A 4 Technical Specifications...
Страница 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Страница 192: ...B 4 ROMPilot BIOS Error Codes...
Страница 202: ...10 Glossary...
Страница 205: ...xx...
Страница 206: ...456 01572 N00...