![background image](http://html1.mh-extra.com/html/nec/express5800-320la/express5800-320la_user-manual_3907234172.webp)
5-18
Problem Solving
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description
Action
CPU2 Temp Alm 00
Amber Blink
CPU module #2
Temperature alarm (lower limit)
CPU2 Temp Alm 02
Amber Lit
CPU module #2
Fatal temperature alarm (lower limit)
CPU2 Temp Alm 07
Amber Blink
CPU module #2
Temperature alarm (upper limit)
CPU2 Temp Alm 09
Amber Lit
CPU module #2
Fatal temperature alarm (upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU2 +12v Alm 00
Amber Blink
CPU module #2
12-V power voltage alarm (lower
limit)
CPU2 +12v Alm 02
Amber Lit
CPU module #2
Fatal 12-V power voltage alarm
(lower limit)
CPU2 +12v Alm 07
Amber Blink
CPU module #2
12-V power voltage alarm (upper
limit)
CPU2 +12v Alm 09
Amber Lit
CPU module #2
Fatal 12-V power voltage alarm
(upper limit)
Contact your service
representative.
CPU2 +2.5vAlm 00
Amber Blink
CPU module #2
2.5-V power voltage alarm (lower
limit)
CPU2 +2.5vAlm 02
Amber Lit
CPU module #2
Fatal 2.5-V power voltage alarm
(lower limit)
CPU2 +2.5vAlm 07
Amber Blink
CPU module #2
2.5-V power voltage alarm (upper
limit)
CPU2 +2.5vAlm 09
Amber Lit
CPU module #2
Fatal 2.5-V power voltage alarm
(upper limit)
CPU2 +3.3vAlm 00
Amber Blink
CPU module #2
3.3-V power voltage alarm (lower
limit)
CPU2 +3.3vAlm 02
Amber Lit
CPU module #2
Fatal 3.3-V power voltage alarm
(lower limit)
CPU2 +3.3vAlm 07
Amber Blink
CPU module #2
3.3-V power voltage alarm (upper
limit)
CPU2 +3.3vAlm 09
Amber Lit
CPU module #2
Fatal 3.3-V power voltage alarm
(upper limit)
CPU2 +5.0vAlm 00
Amber Blink
CPU module #2
5-V power voltage alarm (lower limit)
CPU2 +5.0vAlm 02
Amber Lit
CPU module #2
Fatal 5-V power voltage alarm (lower
limit)
CPU2 +5.0vAlm 07
Amber Blink
CPU module #2
5-V power voltage alarm (upper
limit)
CPU2 +5.0vAlm 09
Amber Lit
CPU module #2
Fatal 5-V power voltage alarm
(upper limit)
CPU2 +5.0vsAlm00
Amber Blink
CPU module #2
5-V power voltage alarm (lower limit)
CPU2 +5.0vsAlm02
Amber Lit
CPU module #2
Fatal 5-V power voltage alarm (lower
limit)
CPU2 +5.0vsAlm07
Amber Blink
CPU module #2
5-V power voltage alarm (upper
limit)
CPU2 +5.0vsAlm09
Amber Lit
CPU module #2
Fatal 5-V power voltage alarm
(upper limit)
CPU2 broken
Green
Blink
CPU module #2
CPU module failure
Contact your service
representative.
CPU2 FAN Alm 01
Amber Blink
CPU module #2
Cooling fan 1 alarm
CPU2 FAN Alm 02
Amber Blink
CPU module #2
Cooling fan 2 alarm
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
Содержание Express5800 320La
Страница 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Страница 2: ...NEC...
Страница 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Страница 40: ...1 26 System Overview...
Страница 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Страница 60: ...2 20 Setting Up the System...
Страница 154: ...4 68 CRU Replacement and Server Upgrades...
Страница 185: ...A Technical Specifications Server Unit...
Страница 188: ...A 4 Technical Specifications...
Страница 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Страница 192: ...B 4 ROMPilot BIOS Error Codes...
Страница 202: ...10 Glossary...
Страница 205: ...xx...
Страница 206: ...456 01572 N00...