![background image](http://html1.mh-extra.com/html/nec/express5800-320la/express5800-320la_user-manual_3907234026.webp)
1-12
System Overview
Table 1-6. Power Supply Status LED Indicators
LED
Description
Response
Power
Pre-Fail
Fail
Off
Off
Off
No AC power.
Check that AC power is available at
the wall outlet.
Check that the system power cords
are properly connected to the power
supplies and the AC wall outlets.
Green
(Flashing
light)
Off
Off
AC present and Standby
On.
None required (normal)
Green
Off
Off
Power supply DC On and
OK
None required (normal)
Off
Off
Amber
Power supply failed.
Replace the power supply.
Green
Off
Amber
(Flashing
light)
Current limit
None required (normal)
Green
Amber
(Flashing
light)
Off
Fan failure.
Replace power supply.