4-28
CRU Replacement and Server Upgrades
Removing a PCI Module
Your system contains two redundant PCI modules that are accessible from the
front of the server unit.
1.
Observe the safety and ESD precautions listed at the beginning of this
chapter.
2.
Unlock and open the front door on the tower cabinet or front covers on the
rack-mount system. See
Opening and Closing the Front Door of the Tower
Cabinet
earlier in this chapter or
Removing and Installing the Front Covers
of the Rack-Mount System
earlier in this chapter.
3.
Ensure that the PCI module is off-line by viewing its status LED indicators
(See Figure 4-33). The state of the status LEDs should be as follows:
Fail lamp:
Red
State lamp:
Off
Figure 4-33. PCI Module Status LED Indicators