Figure 3.2.39: Presets - SCA
)
:
MPX SCA:
Connector
(J7:A for SCA1, J7:B for SCA2)
for use with an externally generated SCA;
select
Enabled
or
Disabled.
When enabled, all the selections listed below are active.
Input Level: signal level that represents 10% modulation. Enter a value between 1 and
5 V p-p (typically 2.83 V p-p).
SCA Reduction
: Attenuation applied to the SCA input; set between 0 and 20% (used to reduce
the modulation level of the main audio when SCAs are enabled; typically, for every 2% of SCA
modulation, the main audio modulation must be reduced by 1%).