![Nautel NV30LT-N Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/nautel/nv30lt-n/nv30lt-n_operation-and-maintenance-manual_3545794035.webp)
NV30LT-N OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-03-01
PAGE 3.2.17
The bottom banner is also permanent on all AUI pages and includes:
RF On
: Click to enable the transmitter’s RF power stage.
RF Off
: Click to disable the transmitter’s RF power stage.
Activity Window
: Displays various messages to reflect specific user interface commands, such as
RF on/off, local/remote control, or reset.
Menu
: Click to open the
Menu
page, which allows navigation to various other pages (see
).
Status
: Click to shortcut to the
Transmitter Status
page (see
Viewing Transmitter Status - AUI on
), which provides current alarm and status details for the transmitter. When the
Status
button is red, one or more alarms of “high” severity is currently being reported and the transmitter
is in an ‘off-air’ state. When the
Status
button is amber, “medium” or yellow “low” one or more
lower level alarms is currently being reported, but the transmitter is still ‘on-air’, possibly at
reduced power. When the
Status
button is green, the transmitter is operating normally. In this case
there are no alarms being reported. This page is also available through the Menu page.
Logs
: Click to shortcut to the
Transmitter Log
page, which displays historical alarm and status
records for the transmitter (see
Viewing Transmitter Log on page 3.2.23
Local/Remote
: Displays the operational control status of the transmitter. From the touch screen,
press the desired button. If
Local
is highlighted green, only local control of the AUI is possible. If
both
Local
and
Remote
are highlighted green, both local and remote controls are enabled.
Reset
: Press to reset protection circuits and restore any RF power modules (and associated power
supplies) that were inhibited, but are now alarm-free. Resets protection circuits that have latched
off the transmitter. To initiate an alarm reset from the front panel display, see
.
Log Out
: Click to log out of the AUI session and return to the login menu. To log in again, use your
remote PC’s keyboard to enter your Username and Password, then click the
Submit
button. If you
do not have a user account, see
User Accounts, on page 3.2.121
The displays between the top and bottom menus, contains user selected pages. These pages provide
access to a variety of AUI functions such as transmitter status and hardware settings. The following
paragraphs describe how to use these pages.
Содержание NV30LT-N
Страница 2: ......
Страница 4: ......
Страница 8: ...NV30LT N OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 1 2015 03 01...
Страница 18: ...NV30LT N OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 10 VERSION 0 1 2015 03 01...
Страница 204: ...NV30LT N OPERATIONS MAINTENANCE MANUAL OPERATING THE TRANSMITTER PAGE 3 2 186 VERSION 0 1 2015 03 01...
Страница 222: ...NV30LT N OPERATIONS MAINTENANCE MANUAL NON STANDARD MAINTENANCE PAGE 3 4 8 VERSION 0 1 2015 03 01...
Страница 224: ...NV30LT N OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 1 2015 03 01...
Страница 225: ......