2-Input, Final Reject Load Assembly
The 2-input, final reject load assemby (A13) provides a means to dissipate reject power from the final
two stages of combining the
20 kW Rej Ld Pwr
output of the 20 kW combiners’ 3 dB hybrid coupler and
the
Final Rej Ld Pwr
output of the 30 kW combiner’s 4.77 dB hybrid coupler. The reject load assembly
contains power resistors to dissipate reject power. Cooling air for the 2-input, final reject load assembly
is provided by fans B10 and B11. The control/monitor stage monitors the speed of the cooling fans and
regulates the voltage being applied to them accordingly.
Reject power generated by the 20 kW combiner and the 30 kW final combiner is dissipated by resistors
in the 2-input, final reject load assembly. Micro-strip transmission lines (on 2-input reject load PWB
A13A1) in close proximity to the reject load signals induces true RF sample voltages of the reject power.
These samples are peak detected and applied to the control/monitor stage via the reject load interface
PWB (A28). The reject load interface PWB provides an interface between the ac-dc power stage’s Rej
Fan Volts supply and the cooling fans. It also acts as the interface between the cooling fans’ Rej Fan
Tach signals and the control/monitor stage.
Output Power Probe
See electrical schematic Figure SD-37. The output power probe (A15) monitors the transmitter's forward
and reflected power and generates the Fwd Pwr Sample (A1J1) and Refld Pwr Sample (A2J1) signals
applied to the control/monitor stage for protection and monitoring. RF monitor PWB A3 provides a
nominal 3.8 V rms [at 30 kW] signal at A3J1, which is applied to the panel mount connector (W8J1)
behind the front, hinged UI panel. This can be used with a modulation monitor or spectrum analyzer. RF
sample PWBs A4 and A5 provide similar samples at A4J1 and A5J1. The sample at A4J1 is applied to
exciter B (if used) for use by the remote AUI’s spectrum analyzer display. The sample at A5J1 is not used
in this configuration. Dc reflected power sample PWB A6 provides a dc voltage representative of the
reflected power sample, for use by the control/monitor stage.
Содержание NV30LT-N
Страница 2: ......
Страница 4: ......
Страница 8: ...NV30LT N OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 1 2015 03 01...
Страница 18: ...NV30LT N OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 10 VERSION 0 1 2015 03 01...
Страница 204: ...NV30LT N OPERATIONS MAINTENANCE MANUAL OPERATING THE TRANSMITTER PAGE 3 2 186 VERSION 0 1 2015 03 01...
Страница 222: ...NV30LT N OPERATIONS MAINTENANCE MANUAL NON STANDARD MAINTENANCE PAGE 3 4 8 VERSION 0 1 2015 03 01...
Страница 224: ...NV30LT N OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 1 2015 03 01...
Страница 225: ......