Appendix A
Specifications
NI PXIe-8133 User Manual
A-4
ni.com
Extended Temperature
Option.......................................–40 to 71 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)
Relative humidity range ..................5% to 95%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Shock and Vibration
Operating Shock .....................................30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits.)
Random Vibration
Operating .........................................5 to 500 Hz, 0.3 g
rms
(with solid-state hard drive)
Nonoperating ...................................5 to 500 Hz, 2.4 g
rms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
Note
Specifications are subject to change without notice.
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note
For UL and other safety certifications, refer to the product label or the
Online
Product Certification
section.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com