background image

Chapter 2

Installation and Configuration

NI PXIe-8133 User Manual

2-12

ni.com

In addition, the following option is available for each detected device if a 
USB mass storage device is present:

Emulation Type

—This setting specifies how the BIOS will present 

the USB mass storage device to the system. This option can be used to 
present a USB mass storage device as a floppy, Zip, hard disk, or 
CD-ROM drive. The default is 

Auto

, which allows the BIOS to treat 

small USB flash disk drives as floppy drives and larger USB flash disk 
drives as hard disk drives.

Serial/Parallel Port Configuration Submenu

Use this submenu to apply alternate configurations to the serial and 
parallel ports. Normally, you do not need to modify these settings, as the 
factory default settings provide the most compatible and optimal 
configuration possible.

Serial Port Configuration

—Use this setting to access the 

Serial Port 

Configuration

 submenu. Refer to the 

Serial Port Configuration 

Submenu

 section for more information.

Parallel Port Configuration

—Use this setting to access the 

Parallel 

Port Configuration

 submenu. Refer to the 

Parallel Port 

Configuration Submenu

 section for more information.

Serial Port Configuration Submenu

Serial Port

—This setting enables or disables the onboard serial port. 

The default value is 

Enabled

.

Device Settings

—This item displays the current base address and 

interrupt request level (IRQ) information for the onboard serial port.

Change Settings

—This setting changes the base address and interrupt 

request level (IRQ) information for the onboard serial port. The default 
value is 

Auto

.

Parallel Port Configuration Submenu

Parallel Port

—This setting enables or disables the onboard parallel 

port. The default value is 

Enabled

Device Settings

—This item displays the current base address and 

interrupt request level (IRQ) information for the onboard parallel port.

Change Settings

—This setting changes the base address and interrupt 

request level (IRQ) information for the onboard parallel port. The 
default value is 

Auto

. Note that the options available vary based upon 

the 

Device Mode

 selected for the parallel port.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание NI PXIe-8133

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ...PXI Express NI PXIe 8133 User Manual NI PXIe 8133 User Manual July 2012 372870D 01 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...orate Headquarters 11500 North Mopac Expressway Austin Texas 78759 3504 USA Tel 512 683 0100 For further support information refer to the Technical Support and Professional Services appendix To comment on National Instruments documentation refer to the National Instruments Web site at ni com info and enter the Info Code feedback 2010 2012 National Instruments All rights reserved Artisan Technology...

Страница 4: ...m or translating in whole or in part without the prior written consent of National Instruments Corporation National Instruments respects the intellectual property of others and we ask our users to do the same NI software is protected by copyright and other intellectual property laws Where NI software may be used to reproduce software or other materials belonging to others you may use NI software o...

Страница 5: ... USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCT...

Страница 6: ...installation when the product is connected to a test object or if the product is used in residential areas To minimize the potential for the product to cause interference to radio and television reception or to experience unacceptable performance degradation install and use this product in strict accordance with the instructions in the product documentation Furthermore any changes or modifications...

Страница 7: ... 2 4 BIOS Setup 2 4 Accessing BIOS Setup 2 4 Main Menu 2 5 Advanced Menu 2 6 PCI Subsystem Settings Submenu 2 7 SATA Configuration Submenu 2 7 CPU Configuration Submenu 2 8 Video Configuration Submenu 2 9 Power Wake Configuration Submenu 2 9 Clock Generator Configuration Submenu 2 10 ExpressCard Configuration Submenu 2 10 USB Configuration Submenu 2 11 Serial Parallel Port Configuration Submenu 2 ...

Страница 8: ...Switches 2 21 Drivers and Software 2 23 Files and Directories Installed on Your Hard Drive 2 23 PXI Express Features 2 24 PXI Express Trigger Connectivity 2 24 PXI Express Chassis Configuration 2 24 PXI Express System Configuration 2 24 Upgrading RAM 2 25 Hard Drive Recovery 2 27 Installing an OS 2 27 Installing from a USB CD DVD ROM 2 27 ExpressCard 2 28 Installing an ExpressCard 2 28 Removing an...

Страница 9: ...s 4 2 Cables and Connections 4 2 Software Driver Installation 4 3 Upgrade Information 4 4 PXI Express Configuration 4 7 Chapter 5 Troubleshooting Appendix A Specifications Appendix B Technical Support and Professional Services Glossary Index Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 10: ...ions to a final action The sequence Options Settings General directs you to pull down the Options menu select the Settings item and select General from the last dialog box This icon denotes a tip which alerts you to advisory information This icon denotes a note which alerts you to important information This icon denotes a caution which advises you of precautions to take to avoid injury data loss o...

Страница 11: ... other examples Related Documentation The following documents contain information you may find helpful as you read this manual PICMG EXP 0 R1 0 CompactPCI Express Specification PCI Industrial Computers Manufacturers Group IEEE Standard P1284 1 1997 C MM Standard for Information Technology for Transport Independent Printer System Interface PCI Express Base Specification Revision 2 1 PCI Special Int...

Страница 12: ...idth PXI Express maximizes both hardware and software compatibility with PXI modules PXI Express hybrid slots deliver both PCI and PCI Express signaling to accept devices that use PXI communication and triggering or the newer PXI Express standard Software compatibility is maintained because PCI Express uses the same OS and driver model as PCI resulting in complete software compatibility among PCI ...

Страница 13: ...integrates standard I O features in a single unit by using state of the art packaging Combining an NI PXIe 8133 embedded controller with a PXI Express compatible chassis such as the NI PXIe 1082 results in a fully PC compatible computer in a compact rugged package The standard I O on each module includes DVI I video one RS 232 serial port a parallel port four high speed USB 2 0 ports a PCI based G...

Страница 14: ...ion of the PXI Express triggers to from the SMB on the front panel The ATI Radeon E2400 Embedded GPU drives the graphics The Watchdog Timer block consists of a watchdog timer that can reset the controller or generate a trigger Intel 5 Series Chipset CPU Intel Core i7 SO DIMM DDR3 SDRAM PC3 10600 DVI VGA Memory Bus Ch A B Express Card 34 Slot x1 PCIE USB USB 2 0 x4 SATA Hard Disk FLASH Watchdog Tri...

Страница 15: ...ard 34 module National Instruments Software National Instruments has developed several software tools you can use with the NI PXIe 8133 National Instruments hardware and software work together to help you make the most of your PXI Express system The LabVIEW Measurement Studio and LabWindows CVI application development environments combine with leading hardware drivers such as NI DAQmx to provide e...

Страница 16: ...XI Express synchronization self calibration messaging and acquiring data to extended memory For more information visit ni com daq National Instruments Modular Instruments use specialized drivers suited to each product s specialization Express VIs provide customized interactive programming of instruments in a single interface and soft front panels provide an interface for testing the functionality ...

Страница 17: ...over two hundred devices on Linux with the NI DAQmx driver you can now create Virtual Instruments based on the Linux OS Instrument control in Linux has been improved by the NI VISA driver for Linux and NI Modular Instruments are partially supported For more information visit ni com linux Cleaning Use a dry low velocity stream of air to clean the NI PXIe 8133 controller If needed use a soft bristle...

Страница 18: ...is before installing the NI PXIe 8133 The power cord grounds the chassis and protects it from electrical damage while you install the module Caution To protect both yourself and the chassis from electrical hazards leave the chassis powered off until you finish installing the NI PXIe 8133 module 2 Remove any filler panels blocking access to the system controller slot slot 1 in the chassis 3 Touch t...

Страница 19: ...or handle as you insert the NI PXIe 8133 The module will not insert properly unless the handle is in its downward position so that it does not interfere with the injector rail on the chassis 6 Hold the handle as you slowly slide the module into the chassis until the handle catches on the injector ejector rail 7 Raise the injector ejector handle until the module firmly seats into the backplane rece...

Страница 20: ...nnector or use the DVI to VGA adapter included with your controller to connect a VGA monitor to the DVI connector 12 Connect devices to ports as required by your system configuration 13 Power on the chassis 14 Verify that the controller boots If the controller does not boot refer to the What if the NI PXIe 8133 does not boot section of Chapter 5 Troubleshooting Figure 2 2 shows an NI PXIe 8133 ins...

Страница 21: ... 8133 configuration settings in the BIOS setup program The BIOS is the low level interface between the hardware and operating system software that configures and tests your hardware when you boot the system The BIOS setup program includes menus for configuring settings and enabling NI PXIe 8133 controller features Most users do not need to use the BIOS setup program as the NI PXIe 8133 controller ...

Страница 22: ...ngs for a selected configuration option Tab Use this key to select time and date fields F9 Use this key to load the optimal default values for BIOS configuration settings The optimal default values are the same as the shipping configuration default values Main Menu The most commonly accessed and modified BIOS settings are in the Main menu The Main menu reports the following configuration informati...

Страница 23: ...ction to restore BIOS settings to their factory defaults The Advanced menu includes the following settings and submenus PCI Subsystem Settings Use this setting to access the PCI Subsystem Settings submenu Refer to the PCI Subsystem Settings Submenu section for more information SATA Configuration Use this setting to access the SATA Configuration submenu Refer to the SATA Configuration Submenu secti...

Страница 24: ...e this setting to adjust the maximum payload size for all PCI Express devices If set to Auto the BIOS will choose an optimal value automatically The default value is 128 Bytes SATA Configuration Submenu Use this submenu to apply alternate settings to the hard disk drive HDD interfaces Normally you do not need to modify these settings as the factory default settings provide the most compatible and ...

Страница 25: ...ling Turbo Boost can also increase application jitter so care should be taken when enabling this setting on a Real Time system To achieve maximum possible Turbo Boost frequencies also enable the C States setting When the BIOS is configured to boot LabVIEW Real time Turbo Boost will be automatically disabled In order to manually enable Turbo Boost performance when in LabVIEW Real Time mode see the ...

Страница 26: ... Submenu Use this submenu to apply alternate configurations to the power and wake features of the chipset and controller Normally you do not need to modify these settings as the factory default settings provide the most compatible and optimal configuration possible Restore After Power Loss This setting specifies the power state that the controller should return to after AC power is lost Valid valu...

Страница 27: ...mine how much memory space I O space and PCI bus numbers will be pre allocated for the ExpressCard port allowing non PCI Express aware operating systems to support hot plugging ExpressCard devices Normally you do not need to modify these settings as the factory default settings provide the most compatible and optimal configuration possible ExpressCard Resources This setting enables or disables the...

Страница 28: ...er When the controller is configured to boot LabVIEW RT legacy USB support is automatically disabled Overcurrent Reporting This setting allows the BIOS to notify the operating system of any USB ports which source too much current The default value for this setting is Disabled Transfer Timeout This setting specifies the timeout value for Control Bulk and Interrupt USB transfers The default value fo...

Страница 29: ...l Port Configuration Use this setting to access the Parallel Port Configuration submenu Refer to the Parallel Port Configuration Submenu section for more information Serial Port Configuration Submenu Serial Port This setting enables or disables the onboard serial port The default value is Enabled Device Settings This item displays the current base address and interrupt request level IRQ informatio...

Страница 30: ...s is invalid use this switch to reset the IP address and other TCP IP settings to their factory defaults during LabVIEW RT startup The default is Use Switch Setting Note By default the target will automatically attempt to connect to the network using DHCP If the target is unable to initiate a DHCP connection the target connects to the network with a link local IP address or 169 254 x x Disable Sta...

Страница 31: ...led When enabled the Intel Boot Agent will be displayed in the Boot Option Priorities menu allowing you to boot from a PXE server on the local subnet Note that the Intel Boot Agent device names are preceded by IBA GE Slot in the Boot Option Priorities menu The system must be restarted for this setting to take effect The default value is Disabled Boot Option Priorities These settings specify the or...

Страница 32: ...Use this setting to access the Network Device BBS Priorities submenu to re order or disable bootable network devices Refer to the Network Device BBS Priorities Submenu section for more information Boot Settings Configuration Submenu Use this submenu to apply alternate configurations to boot settings Normally you do not need to modify these settings as the factory default settings provide the most ...

Страница 33: ...specify the boot priority of network devices The highest priority device is displayed on the main Boot Option Priorities list Optionally each device can also be Disabled if the device should never be used as a boot device Security Menu Use this menu to enable BIOS security options Setup Administrator Password This setting specifies a password that must be entered to access the BIOS setup If only t...

Страница 34: ... The BIOS setup continues to be active Restore Factory Defaults This option restores all BIOS settings to the factory default This option is useful if the controller exhibits unpredictable behavior due to an incorrect or inappropriate BIOS setting Notice that any nondefault settings such as boot order passwords and so on are also restored to their factory defaults The F9 key can also be used to se...

Страница 35: ...been skipped Press any key to continue is displayed In order to continue with testing user interaction is required to press a key on the keyboard Note If either hard drive test fails the controller is not permitted to boot and the user is instructed to turn off the controller and replace the hard drive Memory Diagnostic Utility The memory diagnostic utility is started immediately after the user pr...

Страница 36: ...e following steps to clear the CMOS contents 1 Power off the chassis 2 Remove the controller from the chassis 3 Press the push button switch as shown in Figure 2 3 4 Wait one second 5 Reinstall the controller in the chassis Figure 2 3 Clearing the CMOS Contents 1 Push Button Switch SW2 1 NI PXIe 8133 Embedded Controller Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www ...

Страница 37: ...oads with the basic real time operating system and will automatically attempt to connect to the network using DHCP If DHCP is not available it will then connect to the network with a link local IP address Tip You can connect a monitor to the desktop PC to display startup messages such as the IP address and MAC address 2 Open Measurement Automation Explorer MAX on another computer in the same subne...

Страница 38: ...ess controller view in the Remote Systems branch and select Software 7 Click the Add Remove Software button in the toolbar to launch the LabVIEW Real Time Software Wizard 8 Install the LabVIEW Real Time software and device drivers that you require on the RT target Refer to the NI Web site at ni com info and enter the Info Code etspc for the latest information about supported software After install...

Страница 39: ...the controller with this switch OFF to resume normal operation Switch 3 Disable Startup VI Set this switch to ON to prevent VIs from automatically running at startup if the controller becomes inaccessible because of a startup VI Switch 4 Reset IP Address Set this switch to ON to reset the IP address and other TCP IP settings to their factory defaults Use this switch if moving the controller to a d...

Страница 40: ... logically organized into several levels In the images directory you will find a manuals directory an os directory and a drivers directory The manuals directory contains quick reference guides technical reference manuals and National Instruments software manuals all in Adobe Acrobat format To access any manual change your directory to c images manuals and list the contents of that directory The os...

Страница 41: ...or PXI Platform Services CD included with your kit automatically identifies your PXI Express system components to generate a pxiesys ini and pxisys ini file You can configure your entire PXI Express system through Measurement Automation Explorer MAX included with your controller MAX creates the pxiesys ini and pxisys ini file which define your PXI Express system parameters MAX also provides an int...

Страница 42: ...is ini files to generate the PXI PXI Express system description files pxisys ini and pxiesys ini Device drivers and other utility software read the pxiesys ini and pxisys ini files to obtain system information For detailed information about initialization files refer to the PXI Express specification at www pxisa org Upgrading RAM You can change the amount of installed RAM on the NI PXIe 8133 by up...

Страница 43: ...lf DDR3 SO DIMM modules are not guaranteed to work properly When installing memory modules into the memory sockets the lower socket must be populated first followed by the upper socket If a single memory module is used it must be installed in the lower socket Figure 2 5 Installing a DDR3 SO DIMM in an NI PXIe 8133 Controller 1 DDR3 SO DIMM Module in Lower Socket 2 DDR3 SO DIMM Sockets 2 1 Artisan ...

Страница 44: ...ur factory installed operating system from a CD you can use the included OS re installation CD with an external USB CD DVD ROM drive Boot the PXI Express controller using the OS re installation CD to recover the OS You also may need to reinstall other software after using the CD to recover the OS Note Recovering the OS erases the contents of your hard disk Back up any files you want to keep Instal...

Страница 45: ...omatic eject mechanism If you insert the card and it is ejected simply re insert the card until it is seated If you encounter too much resistance do not force the card Check the card orientation and try again The NI PXIe 8133 will automatically recognize the ExpressCard and load the appropriate driver s Third party cards may require that you install additional drivers Contact your ExpressCard vend...

Страница 46: ...rnet Port 1 LAN RJ45 dual stacked 10 100 1000 Ethernet Intel 82577 WOL capable Ethernet Port 2 LAN RJ45 dual stacked 10 100 1000 Ethernet Intel 82574 Not WOL capable Parallel Parallel Port 36 pin champ IEEE 1284 USB USB 4 pin Series A stacked receptacle 4 ports USB 2 0 capable PXI Express trigger Trigger SMB Routing PXI Express triggers to or from the backplane trigger bus GPIB device GPIB 25 pin ...

Страница 47: ...00 in 0 mm 3 554 in 90 27 mm 4 392 in 111 56 mm 3 727 in 94 67 mm 3 003 in 76 43 mm 3 39 in 86 1 mm 1 541 in 39 14 mm 1 876 in 47 65 mm 2 781 in 70 64 mm 341 in 8 66 mm 1 206 in 30 63 mm 871 in 22 12 mm 0 989 in 25 12 mm 1 435 in 36 45 mm 1 876 in 47 65 mm 0 902 in 22 91 mm 0 000 in 0 mm 1 65 in 41 91 mm 2 064 in 52 43 mm 1 070 in 27 18 mm NI PXIe 8133 Embedded Controller Artisan Technology Group ...

Страница 48: ...I connector signals Figure 3 2 DVI Connector Location and Pinout Table 3 2 DVI I Connector Signals Pin Signal Name 1 TMDS Data2 2 TMDS Data2 3 TMDS Data2 4 Shield 4 Reserved 5 Reserved 6 DDC Clock SCL 7 DDC Data SDA 8 Analog vertical sync 9 TMDS Data1 1 9 17 C4 8 24 C3 C2 C1 C5 NI PXIe 8133 Embedded Controller Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg ...

Страница 49: ... TMDS Data0 18 TMDSData0 19 TMDS Data0 5 Shield 20 Reserved 21 Reserved 22 TMDS Clock Shield 23 TMDS Clock 24 TMDS Clock C1 Analog Red C2 Analog Green C3 Analog Blue C4 Analog Horizontal Sync C5 Analog GND Return analog R G B Table 3 2 DVI I Connector Signals Continued Pin Signal Name Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 50: ...5 Figure 3 3 COM1 Connector Location and Pinout Table 3 3 COM1 Connector Signals Pin Signal Name Signal Description 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RTS Ready to Send 8 CTS Clear to Send 9 RI Ring Indicator Note The pound symbol indicates an active low signal 5 1 6 9 COM1 NI PXIe 8133 Embedded Controller ...

Страница 51: ...connector signals AMP manufactures a mating connector part number 554739 1 Figure 3 4 Ethernet Connector Location and Pinout Table 3 4 Ethernet Connector Signals Pin Fast Ethernet Gigabit Ethernet 1 TX TX_A 2 TX TX_A 3 RX RX_B 4 NC TX_C 5 NC TX_C 6 RX RX_B 7 NC RX_D 8 NC RX_D Ethernet 1 8 8 1 NI PXIe 8133 Embedded Controller Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE...

Страница 52: ...D Color LED State Condition ACT LINK Green Off LAN link is not established On steady state LAN link is established On brighter and pulsing The controller is communicating with another computer on the LAN 10 100 1000 None Off 10 Mbit sec data rate is selected Green On 100 Mbit sec data rate is selected Amber On 1000 Mbit sec data rate is selected Artisan Technology Group Quality Instrumentation Gua...

Страница 53: ...from National Instruments part number 777169 01 Figure 3 5 Parallel Port Connector Location and Pinout Table 3 6 Parallel Port Connector Signals Pin Default Configuration LPT Signal Name Signal Description 1 BUSY Device Busy 2 SLCT Select 3 ACK Acknowledge 4 FAULT ERROR Fault 5 PAPEREND Paper End 6 PD0 Data Bit 0 7 PD1 Data Bit 1 Parallel Port 18 1 36 19 NI PXIe 8133 Embedded Controller Artisan Te...

Страница 54: ...T Initialize Printer 15 STROBE Strobe 16 SLCTIN Select Input 17 AUTOFD Auto Line Feed 18 5V 5 V 19 35 GND Ground 36 NC Not Connected Note The pound symbol indicates an active low signal Table 3 6 Parallel Port Connector Signals Continued Pin Default Configuration LPT Signal Name Signal Description Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 55: ...r has 4 USB ports on the front panel Table 3 7 lists and describes the USB connector signals Figure 3 6 USB Connector Location and Pinout Table 3 7 USB Connector Signals Pin Signal Name Signal Description 1 VCC Cable Power 5 V 2 Data USB Data 3 Data USB Data 4 GND Ground USB 4 1 NI PXIe 8133 Embedded Controller Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg...

Страница 56: ...igger bus Figure 3 7 shows the TRIG connector location on the NI PXIe 8133 Table 3 8 lists and describes the trigger connector signals Figure 3 7 TRIG Connector Location and Pinout Table 3 8 TRIG Connector Signals Pin Signal Name Signal Description 1 TRIG Trigger 2 Shield GND Ground 1 2 NI PXIe 8133 Embedded Controller Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www a...

Страница 57: ...g connector part number MDSM 25SC Z11 V51 Figure 3 8 GPIB Connector Location and Pinout Table 3 9 GPIB Connector Signals Pin Signal Name Signal Description 1 DIO1 Data Bit 1 2 DIO2 Data Bit 2 3 DIO3 Data Bit 3 4 DIO4 Data Bit 4 5 EOI End or Identify 6 DAV Data Valid 7 NRFD Not Ready for Data 8 NDAC Not Data Accepted GPIB 25 14 1 13 NI PXIe 8133 Embedded Controller Artisan Technology Group Quality ...

Страница 58: ...ssis ground 13 DIO5 Data Bit 5 14 DIO6 Data Bit 6 15 DIO7 Data Bit 7 16 DIO8 Data Bit 8 17 REN Remote Enable 18 25 GND Logic Ground Note The pound symbol indicates an active low signal Table 3 9 GPIB Connector Signals Continued Pin Signal Name Signal Description Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 59: ...8133 Table 3 10 lists and describes the ExpressCard connector signals Figure 3 9 ExpressCard 34 Slot Location and Pinout Table 3 10 ExpressCard Connector Signals Pin Signal Name Signal Description 1 GND Ground 2 USBD USB Data 3 USBD USB Data 4 CPUSB USB Presence 5 RESERVED Reserved by spec for future use 6 RESERVED Reserved by spec for future use 7 SMBCLK SMBus Clock ExpressCard 34 Slot 1 26 NI PX...

Страница 60: ...PE Presence 18 REFCLK Reference Clock 19 REFCLK Reference Clock 20 GND Ground 21 PERn0 PE Data Receive 22 PERp0 PE Data Receive 23 GND Ground 24 PETn0 PE Data Transmit 25 PETp0 PE Data Transmit 26 GND Ground Note The pound symbol indicates an active low signal Table 3 10 ExpressCard Connector Signals Continued Pin Signal Name Signal Description Artisan Technology Group Quality Instrumentation Guar...

Страница 61: ... onboard power supplies is operating outside of the normal limits or the system power supply is out of regulation OFF The controller is powered off Red BLINKING The controller detected a power rail fault when trying to boot The DRIVE LED indicates when an access to the internal hard disk is occurring Data Storage The NI PXIe 8133 has the following data storage features Internal Serial ATA hard dri...

Страница 62: ...3 s port 1 Intel 82577 Ethernet device remains powered even after shutdown It is safe to remove your controller or disconnect power How do I check the configuration of the memory hard drive time date and so on You can view these parameters in the BIOS setup To enter the BIOS setup reboot the NI PXIe 8133 and press Delete during the memory tests Refer to the Accessing BIOS Setup section of Chapter ...

Страница 63: ...vices There are two methods Enter the BIOS setup by rebooting the controller and pressing Delete during the memory tests Select the Boot menu You will see a list of all bootable devices ordered by device type You can set the boot order by altering the Boot Option 1 Boot Option 2 and Boot Option 3 settings To boot from a different device without permanently changing the boot order press F10 during ...

Страница 64: ...ftware Driver Installation How do I install or reinstall the video driver Refer to KnowledgeBase 3H3COSD8 What Peripheral Drivers Should I Use with My PXI or VXI Controller at ni com support How do I install or reinstall the Ethernet driver Refer to KnowledgeBase 3H3COSD8 What Peripheral Drivers Should I Use with My PXI or VXI Controller at ni com support How do I install or reinstall the GPIB dri...

Страница 65: ...National Instruments part number 778492 01 Upgrade Information How do I upgrade system memory You can change the amount of installed RAM on the NI PXIe 8133 by upgrading the DDR3 SO DIMMs To upgrade the RAM remove the NI PXIe 8133 from the PXI Express chassis To optimize both memory capacity and system performance use the same size and speed memory module in each of the two module slots The use of...

Страница 66: ...e memory sockets the lower socket must be populated first followed by the upper socket If a single memory module is used it must be installed in the lower socket Figure 4 2 Installing a DDR3 SO DIMM in an NI PXIe 8133 Controller How do I flash a new BIOS You can download the new BIOS from ftp ni com support pxi For more information refer to KnowledgeBase 2GIGKD0Z Determining and Upgrading PXI and ...

Страница 67: ...n the default position with the shunt on pins 1 and 2 or with the shunt removed entirely If the shunt is in the wrong position the BIOS will display a warning message Where do I get the latest software drivers The latest National Instruments software is available from ni com downloads For peripheral drivers refer to KnowledgeBase 3H3COSD8 What Peripheral Drivers Should I Use with My PXI or VXI Con...

Страница 68: ...able from National Instruments part number 778492 02 PXI Express Configuration How do I use the SMB trigger on the front panel For details refer to the PXI Express Features section of Chapter 2 Installation and Configuration Why doesn t the NI PXIe 8133 work with the PXI 8220 or PXI 8221 The serialized IRQ line is not routed to the Intel 5 Series chipset on the NI PXIe 8133 This prevents PC cards ...

Страница 69: ...t that you saw for reference when consulting National Instruments technical support What has changed about the system Did you recently move the system Was there electrical storm activity Did you recently add a new module memory chip or piece of software Refer to your chassis user manual for additional troubleshooting steps Things to Try Make sure the chassis is plugged in to a working power source...

Страница 70: ...rol Panel Alternately you can try a different monitor preferably a newer and larger one My system boots fine as long as a particular module is not in my chassis The most common cause of this is a damaged module Try the module in a different chassis or with a different controller Also remove any external cables or terminal blocks connected to the system If the module does not work in these cases it...

Страница 71: ...ear CMOS button SW2 as shown in Figure 5 1 4 Wait one second 5 Reinstall the controller in the chassis Figure 5 1 Clearing the CMOS Contents 1 Push Button Switch SW2 1 NI PXIe 8133 Embedded Controller Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 72: ... 100 1000 BaseTX 2 ports PXI Express 4 Link Configuration x4 x4 x4 x4 PXI Express 2 Link Configuration x4 x4 GPIB IEEE 488 Controller Yes Serial Ports RS 232 Yes 1 Parallel Port Yes 1 Hi Speed USB 2 0 Ports Yes 4 ExpressCard 34 Slot Yes PS 2 Keyboard Mouse Connector No PXI Express Trigger Bus Input Output Yes Installed Operating System Windows 7 Professional Windows XP Professional SP3 for Embedde...

Страница 73: ...cal Environment Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor use only Caution Clean the NI PXIe 8133 with a soft nonmetallic brush Make sure that the device is completely dry and free from contaminants before returning it to service Voltage V Current Amps Typical Maximum 3 3 V 3 1 A 4 6 A 5 V 2 2 A 3 3 A 12 V 4 8 A 7 2 A 12 V 0 00 A 0 00 A 5 V Aux 0 29 A ...

Страница 74: ...ass 2 high temperature limit Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Caution The operating temperature must not be exceeded even when used in a chassis with a higher temperature range Storage Environment NI PXIe 8133 Ambient temperature range Standard 40 to 65 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 lo...

Страница 75: ... Hz 0 3 grms with solid state hard drive Nonoperating 5 to 500 Hz 2 4 grms Tested in accordance with IEC 60068 2 64 Nonoperating test profile exceeds the requirements of MIL PRF 28800F Class 3 Note Specifications are subject to change without notice Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and lab...

Страница 76: ... intentionally generates radio frequency energy for the treatment of material or inspection analysis purposes Note For EMC declarations and certifications and additional information refer to the Online Product Certification section CE Compliance This product meets the essential requirements of applicable European Directives as follows 2006 95 EC Low Voltage Directive safety 2004 108 EC Electromagn...

Страница 77: ...EC on Waste and Electronic Equipment visit ni com environment weee Battery Replacement and Disposal This device contains a long life coin cell battery If you need to replace it use the Return Material Authorization RMA process or contact an authorized National Instruments service representative For more information about compliance with the EU Battery Directive 2006 66 EC about Batteries and Accum...

Страница 78: ...d Service Program Membership This program entitles members to direct access to NI Applications Engineers via phone and email for one to one technical support as well as exclusive access to eLearning training modules at ni com elearning All customers automatically receive a one year membership in the Standard Service Program SSP with the purchase of most software products and bundles including NI D...

Страница 79: ...acturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification Calibration Certificate If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration You also can visit the Worldwide Offices section of...

Страница 80: ... B B Bytes backplane An assembly typically a printed circuit board with connectors and signal paths that bus the connector pins BIOS Basic Input Output System BIOS functions are the fundamental level of any PC or compatible computer BIOS functions embody the basic operations needed for successful use of the computer s hardware resources Artisan Technology Group Quality Instrumentation Guaranteed 8...

Страница 81: ...ggedness of a rack mount system D DC Direct Current DDR Double Data Rate DMA Direct Memory Access A method by which data is transferred between devices and internal memory without intervention of the central processing unit DVI Digital Visual Interface A video connector designed to maximize the visual quality of digital display devices such as flat panel LCD computer displays and digital projector...

Страница 82: ...ertz Cycles per second I I O Input Output The techniques media and devices used to achieve communication between machines and users IDE Integrated Drive Electronics Hard disk and built in controller IEEE Institute of Electrical and Electronics Engineers in Inches instrument driver A set of routines designed to control a specific instrument or family of instruments and any necessary related files f...

Страница 83: ...ter A functional part of a PXI Express device that initiates data transfers on the PXI Express backplane A transfer can be either a read or a write MB Megabytes of memory MTBF Mean time between failure N NI 488 or NI 488 2 The National Instruments software for GPIB systems NI DAQ The National Instruments software for data acquisition instruments NI VISA The National Instruments implementation of t...

Страница 84: ...umentation applications by providing triggering local buses and system clock capabilities PXI Express also offers two way interoperability with CompactPCI Express products R RAM Random Access Memory The computer s primary workspace resource Hardware settings used by devices in a computer system including ISA interrupt level DMA channel and I O address RMS Root mean squared See also grms S s Second...

Страница 85: ...Manual G 6 ni com U USB Universal Serial Bus V V Volts VGA Video Graphics Array The minimum video display standard for all PCs W W Watts Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 86: ... Configuration menu 2 7 Save Exit menu 2 17 Serial Parallel Port Configuration menu Parallel Port menu 2 12 Serial Port menu 2 12 USB configuration menu 2 11 Video Configuration menu 2 9 Boot menu 2 14 boot options configuring controller 4 2 Boot Settings Configuration menu 2 15 C calibration certificate NI resources B 2 CD DVD ROM Drive BBS Priorities menu 2 16 CE compliance specifications A 5 Cl...

Страница 87: ...n GPIB IEEE 488 2 4 3 video 4 3 NI resources B 1 obtaining latest drivers 4 6 DVI I connector signals table 3 3 E electrical specifications A 2 electromagnetic compatibility A 5 environmental management specifications A 5 battery replacement and disposal A 6 WEEE information A 6 Ethernet connector 3 1 location and pinout figure 3 6 signals table 3 6 examples NI resources B 1 ExpressCard configurat...

Страница 88: ...D DVD ROM 2 27 overview 2 27 installing the GPIB driver 4 3 installing the video driver 4 3 instrument drivers NI resources B 1 Intel 5 Series chipset 1 4 K keyboard plugging PS 2 mouse and keyboard into controller 4 2 KnowledgeBase B 1 L LabVIEW 1 4 RT configuration switches 2 21 RT installation and configuration 2 20 RT options menu 2 13 RT software installation 2 20 LabVIEW RT configuration swi...

Страница 89: ...2 1 figure 2 3 logic blocks 1 3 peripheral expansion overview table 3 1 PXI Express trigger connectivity 2 24 removing from a PXI Express chassis 2 4 software 1 4 specifications A 1 troubleshooting 5 1 upgrading RAM 2 25 4 4 NI DAQmx 1 5 NI VISA 1 5 O operating environment specifications A 2 A 3 OS directory 2 23 OS installation from USB CD DVD ROM 2 27 overview 2 27 P parallel port connector 3 1 ...

Страница 90: ...1 4 NI resources B 1 NI DAQmx 1 5 NI VISA 1 5 specifications CE compliance A 5 electrical A 2 electromagnetic compatibility A 5 environmental management A 5 battery replacement and disposal A 6 WEEE information A 6 features A 1 online product certification A 5 operating environment A 2 A 3 physical A 2 safety A 4 shock and vibration A 4 storage environment A 3 storage environment specifications A ...

Страница 91: ...ion menu 2 11 V VGA location and pinout figure 3 3 overview table 3 1 video 3 1 See also VGA driver installation 4 3 Video Configuration menu 2 9 W W1 jumper 4 6 Web resources B 1 WEEE information A 6 Y Y splitter cable figure 4 3 using mouse and keyboard without 4 3 using with PS 2 mouse and keyboard 2 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 92: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Отзывы: