installation planning
2.4 installation option 4 - open enclosure with hard combustible valance
ceiling
4” min
air outlet opening
must be continuous
around enclosure top.
6” Max.
6” Min.
6” Min.
ALTERNATIVE
DYNAMIC HEAT
CONTROL™ AIR
OUTLET OPEN-
ING IS HOT WHEN
APPLIANCE IS
OPERATING!
NOTE: Air outlet opening must be at least continuous
around the top of the enclosure for a valance to be permit-
ted. Using the minimum air outlet opening from option 1 or 2
is not permitted and will overheat the appliance.
Air outlet opening must be located out of reach of the user.
Air outlet
must
not be restricted by furnishings or decor.
Wall mounted object
(picture frame, appli-
ance, etc.)
ABSOLUTELY NO OBSTRUCTION OR RESTRICTION AL-
LOWED IN THE ENTIRE SHADED AREA WITH THE EXCEP-
TION OF APPROVED VENTING
is similar to option 1 with the addition of a hard combustible valance. Minimum opening dimensions and valance dimensions
must
be followed (See option 4 diagram).
Restricting air movement within the valance area will overheat the appliance,
the enclosure, and finishing material.
See-thru appliances require front or rear air outlet opening. If desired, it can be installed with both front and rear air outlet openings
to allow heat to circulate in two rooms however it is recommended to install the air outlet opening at different heights that meet the
installation parameters for aesthetic purposes. For
Dynamic Heat Control™
plus, a second opening
MUST NOT
be installed
note:
NOT Suitable for Dynamic Heat Control™ Plus