Dynamic Heat Control™ installation
4.0 Dynamic Heat Control™ installation
1.) Remove fasteners securing front frame (and rear
frame for see-thru).
Do not discard fasteners.
Before starting the Dynamic Heat Control™ installation, remove safety barrier. Refer to “safety barrier installation/
removal” section in the installation manual
SINGLE-SIDED SHOWN
SINGLE-SIDED SHOWN
2.) Remove knockouts plates
(FOR SINGLE-SIDED, ONLY REMOVE
THE TWO KNOCKOUTS PLATES ON THE ACCESS SIDE)
. Discard
knockout plates.
Recommended: Use a flathead screwdriver or a
small pry bar and use prying motion to remove the knockout
. Use
a brace such as a piece of wood under the prying tool to avoid distorting
the top
3.) Remove the fasteners securing the cover plates recessed below the knockout plates. For ease of removal, lift the panel from below in
front of the firebox door. Discard cover plates.
access side
access side
COVER PLATE
IMPORTANT:
Fire Hazard Warning: This step is crucial for your appliance to work properly. If
the knockout plates AND the cover plates are not removed from the viewed side,
the appliance will overheat, the barrier will become excessively hot, and the high
limit switch will constantly trip.
Front Frame
Cover Plate