finish framing - after appliance installation
8.0 finish framing - after appliance installation
single-sided flush
Before framing the appliance, ensure to install the firestop first as it will not fit between the studs if installed after
framing.
There are various methods to ventilate the enclosure. Refer to “Installation Planning” section. Only one option is
illustrated (option 2 - front opening).
note:
Ref
LV38-1
LV50-2
LV62
LV74
K
39 15/16” (101.4cm)
39 15/16” (101.4cm)
39 15/16” (101.4cm)
39 15/16” (101.4cm)
E
20 1/8” (51.1cm)
20 1/8” (51.1cm)
20 1/8” (51.1cm)
20 1/8” (51.1cm)
F
53 13/16” (136.7cm)
65 13/16” (167.2cm)
77 13/16” (197.6cm)
89 13/16” (228.1cm)
J
Optional - Appliance does not need to be elevated above floor
L
73” (185.4cm)
73” (185.4cm)
91” (231.1cm)
91” (231.1cm)
Q*
2” min and 3” max
(Q x R)*
80 sq. in.
160 sq. in.
minimum framing
Drywall
Insulation
Ceiling
K
R
E
F
J
L
Q
Option 2 illustrated (appliance not shown)
Finish framing
must
be built after
appliance has been placed in its
final position and
venting connected.
note:
* ONLY APPLICABLE TO OPTION 2 AND 3 - Opening
must
be centered in enclosure on appliance. Dimensions represent
finished sizes and where applicable should be adjusted to include finish material thickness.
Although the minimum enclosure
height for the LV series is 73”,
some venting configurations
that require more vertical rise
will require a larger enclosure to
provide minimum vertical clear-
ance between vent pipes and
combustibles.