23

System Troubles 

Use the System Trouble chart on the following 
page to determine the specific System Trouble(s). 

 

During normal panel operation the 

H

 

SYSTEM 

TROUBLE LED has the following two modes of 
operation: 
 

     

STEADY

            1-7 possible trouble 

                                  groups, AC is present 

     

FLASHING

        1-7 possible trouble 

                                   groups, AC is not present 

 

Viewing System Trouble(s)   

Press the 

i

 SYSTEM key on the keypad.   

To determine the System Trouble Group 
Number, count the number of times the 

H

SYS-

TEM LED blinks.  The keypad sounder will beep 
at the same rate that the 

H

SYSTEM LED 

blinks.  

 

To determine the System Trouble, note the zone 
LED that is ON.  Look up the specific system 
trouble on the chart on the following page. 

 

The 

H

SYSTEM LED and keypad sounder will 

continue to flash and beep.  To view the next 
System Trouble, if any, press the 

B

 key.  

Continue pressing the 

B

 key, if there are no 

more system troubles to view, the system will 
return to normal operation. 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Note:

 System Troubles Groups 3 through 7 -  

System Trouble Groups that have a zone or 
smoke detector associated with the trouble,  
such as RF low battery.  The zone(s) of the 
device with a low battery will be displayed by the 
ZONE LED.  For example, a wireless low battery 

on zone 2 would beep the keypad sounder 3 
times and turn on zone 2 LED. 
 

Audible System Trouble Indication

 - For all 

system troubles, except when the only system 
trouble is the loss of AC, the keypad will beep 
once every 10 seconds.  The keypad will 
continue to beep until the reset button is pressed 
or the trouble has been acknowledged by 
pressing the 

i

 key. 

 

System Trouble Reporting 

The following system troubles, when enabled to 
report to Telco 1 [37-3] or Telco 3 [57-3], will 
send the report code programmed in Trouble 
Report [63] if reporting using a pulse format:  

                  

System Trouble        Pulse Report Code

 

Bell Cut                             F1 
2-Wire Fire Trouble           F1 
Rcvr Fail-to-Respond        F1 
Receiver Tamper               F1 
Receiver JAM                    F1 
Tx Low Battery                  F1 
Tx Supervisory Failure       F1 

                         

If reporting using Point ID, a unique code will be 
sent for each of the following System Troubles. 

 

System Trouble        Point ID Report Codes

 

Bell Cut                             CODE 1 321 G00 ZN000-BELL 1 TROUBLE 
2-Wire Fire Trouble           CODE 1 373 G00 ZN000-FIRE LOOP TRBLE 
Rcvr Fail-to-Respond        CODE 1 382 G00 ZN000-SENSOR TROUBLE 
Receiver Tamper               CODE 1 145 G00 ZN000-EXP. MODL. TAMPER 
Receiver JAM                    CODE 1 373 G00 ZN000-FIRE LOOP TRBLE 

 

300

 (SYSTEM TROUBLE RST) code is sent if a restore is 

reported after multiple troubles.

 

System Trouble 

Group # 

 

Keypad 

H

SYSTEM 

Trouble LED is flashing 
1 time indicating System 
Trouble Group 1. 
 
Keypad Sounder beeps 
1 time indicating System 
Trouble Group 1. 

EXAMPLE

 -

 

LOW

 

BATTERY

 

SYSTEM

 

TROUBLE

 

Zone LED(s)

 is ON  

indicates 
(Specific Trouble) 

Specific Trouble

 

 
Zone 2 LED is ON indicating 
Low Battery. (1 Beep, LED 2) 

Flashing

 

(System  
Trouble  
Group  
Number)  

Press the 

i

 to enter System Trouble mode and 

determine the specific trouble.  Press any key to 
view all system troubles. 

Beeping 

(System 
Trouble 
Group  
Number) 

FIGURE

 

9

 S

YSTEM

 T

ROUBLE

 E

XAMPLE

 

Содержание RPXP6GT

Страница 1: ...XP 600 RPXP6GT keypad Control Panel Communicator Installation Instructions WI1372 1 05 NAPCO 2005...

Страница 2: ...Line Cut Detection Answering Machine Override Second Call 50 Event Log Communicator 2 Telephone Numbers Backup Reporting Pager Format Point ID Format Individually Report 6 Users Opening after Alarm R...

Страница 3: ...Battery 12V 4 AH Rechargeable Change Battery every 5 years or as required Maximum Charging Current 165 mA Maximum Input Current 2 58 A Loop Characteristics Loop Voltage 5 Volts Loop Current Zones 1 2...

Страница 4: ...ss PIR Wireless Dual Technology Sensor Wireless Glass Break Detector Relay Board Audio Verification Module Downloading Software for IBM PC Compatibles Software with Interface for IBM PC Compatibles in...

Страница 5: ...ng PCPreset For Site Initiated Downloaded see Auto Download ID Number 93 Local Downloading Wire as shown in Figure 1 Use the power up or A6 method of establishing a connection The power up method is r...

Страница 6: ...eat detectors rather than smoke detectors are recommended in kitchens attics and garages due to conditions that may result in false alarms and improper operation Refer to NFPA Standard 74 National Fir...

Страница 7: ...mA Keypad Operation Keypad zone LEDs indicate zone status W ARMED X READY and HSYSTEM LEDs provide system status The keypad sounder provides feedback beeps for correct and incorrect entries Keypad So...

Страница 8: ...y Follower Zones can be bypassed when the M or N keys on the Keyfob have been programmed for Interior 81 84 Zones programmed as Home Away with Delay Zones can be armed regardless of the state of the E...

Страница 9: ...omatic Bypassing Home Away with Delay Zones From the Keypad Press C B to return protection to Home Away with Delay Zones that have been automatically bypassed Three minutes are allowed to walk through...

Страница 10: ...rogram Mode press the b key XP 600 Commands User Commands A 1 Bell Test Enter this command to turn on the Bell keypad sounder and keypad LEDs for 2 seconds The battery is tested during a Bell Test and...

Страница 11: ...ds when hardwired zones are faulted and for 1 second when zones are restored Wireless Operation Signal Strength While in Fault Find mode the keypad will provide an audible Table 6 and visual Figure 5...

Страница 12: ...lows exit after the panel is armed without setting off an immediate alarm and allows entry only if an Exit Entry Zone 00 has been violated first Zones of this type have a three 3 minute power up delay...

Страница 13: ...it through an Exit Entry Zone 00 after the system is armed allows a user to leave the premises without setting off an immediate alarm Exit Delay may be programmed for up to 255 seconds 4 minutes a val...

Страница 14: ...000 Downloading Software On power up the test timer is sent immediately Follow the commands below to offset the test timer using Quickloader Software From the Status Screen Press F6 Select Miscellaneo...

Страница 15: ...armed or 2 two times when the panel is disarmed Wire as shown in Figure 7 24 Programmable Output Features 2 1 I Fire Program to activate the PGM on a Fire alarm 2 AUX Program to activate the PGM on a...

Страница 16: ...orrect data the panel sends a Sumcheck digit after sending the Subscriber ID and Alarm Code 3 Single Digit 3 1 Format 3 digit Subscriber ID number and a 1 digit Alarm Code will be transmitted 4 No Han...

Страница 17: ...icator Enabled Program to enable the communicator 2 DTMF with Rotary Backup The first attempt to communicate is dialed using the TouchTone method of dialing subsequent attempts are dialed using the pu...

Страница 18: ...st digit of the report code sent the second digit is the zone number of the reporting zone For example if zone 2 has a report code of 3 the report code would be 32 3 1 format Sends only the report Cod...

Страница 19: ...de 62 2 is used to report zones that have been bypassed at the time of the closing report 3 Reserved 4 Reserved 68 Telephone Number 3 1 Opening after Alarm Cancel Code see 67 1 2 Conditional Closing T...

Страница 20: ...1 36 2 and or Telco 3 56 3 Audible Panic Optional 21 1 2 AUX Program a 2 in the AUX 1 and or AUX 2 option to initiate a AUX alarm when the M or N buttons on the Keyfob are pressed Additional programm...

Страница 21: ...s 1 Ring Method Enable the ring method of downloading The panel will pick up on the number of rings programmed in Ring Count 91 2 Answering Machine Override Using the downloading computer call the pan...

Страница 22: ...ollowing UL required features There is a 4 hour re sound of wireless Smoke Low Battery and wireless Smoke Supervisory system troubles An active System Battery test performed every 4 hours instead of 2...

Страница 23: ...e keypad will beep once every 10 seconds The keypad will continue to beep until the reset button is pressed or the trouble has been acknowledged by pressing the i key System Trouble Reporting The foll...

Страница 24: ...A signal is blocking the normal reception of transmissions from the wireless devices Ensure that the green LED on the receiver is not on continuously refer to receiver manual WI848 3 Beeps 1 6 Wireles...

Страница 25: ...flowing through the Bell circuit for supervision To eliminate the buzzing cut resistor R26 which is located directly above Terminal 9 just below the heat sink 5 Where are the fuses The control panel...

Страница 26: ...1 and point 2 is jumped out If using internal reed make sure J1 is cut and both Point 1 and Point 2 terminals are jumped out 10 Keypad LEDs Flicker The Keypad is not receiving a POLL from the Panel Ch...

Страница 27: ...Out Power In Fire Loop Out RED BLACK BROWN BROWN FT2200 8 7 8 9 Power In Fire Power Ground Fire Power Fire 2 2K 2 2K Normally Open Zone Wiring Wire the normally open contact as shown Zone 4 Program t...

Страница 28: ...Despite frequent testing and due to but not limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expec...

Отзывы: