NAPCO RPXP6GT Скачать руководство пользователя страница 11

11

A

 

8

 + User 1 Code - User Program 

Mode 

 

A

 

9

 Keypad Sleep Mode ON/OFF 

Enter this command to turn the keypad sounder 
ON/OFF. When the keypad is in Sleep mode all 
keypad sounds will be silenced except for 
keypad feedback beeps and Keypad Sounder 
on Alarm.   

 

User Commands - Optional 

 

A 0

 Easy Exit/Easy Arm 

If enabled in Dealer programming, enter this 
command while the panel is Armed to allow 3 
minutes to exit the premises through 

Exit/Entry 

and 

Exit/Entry Follower Zones

.   Enter 

a0

 

to arm the panel.   To disarm the panel a valid 
Arm/Disarm code must be entered.  Requires 

Easy Exit/Easy Arm [

21-2] to be enabled. 

 
 

A

 

3

 Access on PGM  

If enabled in Dealer programming, enter this 
command to activate the PGM output (Terminal 
15) for 5 seconds. 

 
Dealer Commands  

 

A 6

 Dow nload (Pr ogr ammin g 

Required) 

Establish a connection between the PCD phone 
line and the Control Panel phone line. When 

ready, tell the installer to arm, then disarm. Then 
enter 

A

 

6

 in order to establish a connection. 

Phone connection to installer will go "dead" as 
downloader and panel connect. 

 

A

 

7

 Fault Find ON/OFF   

Hardwired Zone Operation   
Enter this command to turn Fault Find ON/OFF.  
While in Fault Find mode, the loop response for 
all zones will be set to the faster response of 40 
ms.  The keypad will beep for .25-seconds when 
hardwired zones are faulted and for 1-second 
when zones are restored.  

 

Wireless Operation   
(Signal Strength)  

While in Fault Find mode the keypad will provide 
an audible (Table 6) and visual (Figure 5)  
indication of each transmitter’s signal strength.  
The signal strength metering is based on a scale 
of 4 to 10, with 4 being marginal and 10 being 
excellent. 
 
The keypad will beep out a number, from 1-4,  
corresponding to the signal strength of the 
transmitter. See Table 6.  Each beep is 1-
second long.  The keypad will sound a short 
beep for transmitters with signal strengths of 3 
or less. 

 

 
 
 
 
 
 

 
 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
Signal Strength Logging Mode 

The Signal Strength Logging Mode is a 
troubleshooting tool which allows the collection 
of signal strength information for all transmitters 
on the system. Normally the Signal Strength of 
Supervisory Signals are not logged; during 
Signal Strength Logging Mode the signal 
strength information for all supervisory signals 
received over a two hour period will be saved to 
the LOG.   

Local Activation 

Enable [92-4=ON], this will initiate a two hour 
test period where all supervisory signals will log 
signal strength information.   
 

TABLE

 

6  A

UDIBLE

 S

IGNAL

 S

TRENGTH

 I

NDICATION

 

FIGURE

 

5

 V

ISUAL

 S

IGNAL

 S

TRENGTH

 I

NDICATION

 

5 6-7 

4 8-10 

ZONE 1 

ZONE 2 

ZONE 3 

ZONE 4 

ZONE 1 

ZONE 2 

ZONE 3 

ZONE 4 

ZONE 1 

ZONE 2 

ZONE 3 

ZONE 4 

ZONE 1 

ZONE 2 

ZONE 3 

ZONE 4 

SIGNAL

 

STRENGTH

 

KEYPAD

 

SOUNDER

 

3 or less 

.25

S

 

BEEP

 

BEEP

 

BEEP

 

BEEP

 

6-7 

BEEP

 

BEEP

 

BEEP

 

8-10 

BEEP

 

BEEP

 

BEEP

 

BEEP

 

Содержание RPXP6GT

Страница 1: ...XP 600 RPXP6GT keypad Control Panel Communicator Installation Instructions WI1372 1 05 NAPCO 2005...

Страница 2: ...Line Cut Detection Answering Machine Override Second Call 50 Event Log Communicator 2 Telephone Numbers Backup Reporting Pager Format Point ID Format Individually Report 6 Users Opening after Alarm R...

Страница 3: ...Battery 12V 4 AH Rechargeable Change Battery every 5 years or as required Maximum Charging Current 165 mA Maximum Input Current 2 58 A Loop Characteristics Loop Voltage 5 Volts Loop Current Zones 1 2...

Страница 4: ...ss PIR Wireless Dual Technology Sensor Wireless Glass Break Detector Relay Board Audio Verification Module Downloading Software for IBM PC Compatibles Software with Interface for IBM PC Compatibles in...

Страница 5: ...ng PCPreset For Site Initiated Downloaded see Auto Download ID Number 93 Local Downloading Wire as shown in Figure 1 Use the power up or A6 method of establishing a connection The power up method is r...

Страница 6: ...eat detectors rather than smoke detectors are recommended in kitchens attics and garages due to conditions that may result in false alarms and improper operation Refer to NFPA Standard 74 National Fir...

Страница 7: ...mA Keypad Operation Keypad zone LEDs indicate zone status W ARMED X READY and HSYSTEM LEDs provide system status The keypad sounder provides feedback beeps for correct and incorrect entries Keypad So...

Страница 8: ...y Follower Zones can be bypassed when the M or N keys on the Keyfob have been programmed for Interior 81 84 Zones programmed as Home Away with Delay Zones can be armed regardless of the state of the E...

Страница 9: ...omatic Bypassing Home Away with Delay Zones From the Keypad Press C B to return protection to Home Away with Delay Zones that have been automatically bypassed Three minutes are allowed to walk through...

Страница 10: ...rogram Mode press the b key XP 600 Commands User Commands A 1 Bell Test Enter this command to turn on the Bell keypad sounder and keypad LEDs for 2 seconds The battery is tested during a Bell Test and...

Страница 11: ...ds when hardwired zones are faulted and for 1 second when zones are restored Wireless Operation Signal Strength While in Fault Find mode the keypad will provide an audible Table 6 and visual Figure 5...

Страница 12: ...lows exit after the panel is armed without setting off an immediate alarm and allows entry only if an Exit Entry Zone 00 has been violated first Zones of this type have a three 3 minute power up delay...

Страница 13: ...it through an Exit Entry Zone 00 after the system is armed allows a user to leave the premises without setting off an immediate alarm Exit Delay may be programmed for up to 255 seconds 4 minutes a val...

Страница 14: ...000 Downloading Software On power up the test timer is sent immediately Follow the commands below to offset the test timer using Quickloader Software From the Status Screen Press F6 Select Miscellaneo...

Страница 15: ...armed or 2 two times when the panel is disarmed Wire as shown in Figure 7 24 Programmable Output Features 2 1 I Fire Program to activate the PGM on a Fire alarm 2 AUX Program to activate the PGM on a...

Страница 16: ...orrect data the panel sends a Sumcheck digit after sending the Subscriber ID and Alarm Code 3 Single Digit 3 1 Format 3 digit Subscriber ID number and a 1 digit Alarm Code will be transmitted 4 No Han...

Страница 17: ...icator Enabled Program to enable the communicator 2 DTMF with Rotary Backup The first attempt to communicate is dialed using the TouchTone method of dialing subsequent attempts are dialed using the pu...

Страница 18: ...st digit of the report code sent the second digit is the zone number of the reporting zone For example if zone 2 has a report code of 3 the report code would be 32 3 1 format Sends only the report Cod...

Страница 19: ...de 62 2 is used to report zones that have been bypassed at the time of the closing report 3 Reserved 4 Reserved 68 Telephone Number 3 1 Opening after Alarm Cancel Code see 67 1 2 Conditional Closing T...

Страница 20: ...1 36 2 and or Telco 3 56 3 Audible Panic Optional 21 1 2 AUX Program a 2 in the AUX 1 and or AUX 2 option to initiate a AUX alarm when the M or N buttons on the Keyfob are pressed Additional programm...

Страница 21: ...s 1 Ring Method Enable the ring method of downloading The panel will pick up on the number of rings programmed in Ring Count 91 2 Answering Machine Override Using the downloading computer call the pan...

Страница 22: ...ollowing UL required features There is a 4 hour re sound of wireless Smoke Low Battery and wireless Smoke Supervisory system troubles An active System Battery test performed every 4 hours instead of 2...

Страница 23: ...e keypad will beep once every 10 seconds The keypad will continue to beep until the reset button is pressed or the trouble has been acknowledged by pressing the i key System Trouble Reporting The foll...

Страница 24: ...A signal is blocking the normal reception of transmissions from the wireless devices Ensure that the green LED on the receiver is not on continuously refer to receiver manual WI848 3 Beeps 1 6 Wireles...

Страница 25: ...flowing through the Bell circuit for supervision To eliminate the buzzing cut resistor R26 which is located directly above Terminal 9 just below the heat sink 5 Where are the fuses The control panel...

Страница 26: ...1 and point 2 is jumped out If using internal reed make sure J1 is cut and both Point 1 and Point 2 terminals are jumped out 10 Keypad LEDs Flicker The Keypad is not receiving a POLL from the Panel Ch...

Страница 27: ...Out Power In Fire Loop Out RED BLACK BROWN BROWN FT2200 8 7 8 9 Power In Fire Power Ground Fire Power Fire 2 2K 2 2K Normally Open Zone Wiring Wire the normally open contact as shown Zone 4 Program t...

Страница 28: ...Despite frequent testing and due to but not limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expec...

Отзывы: