[22]Miscellaneous Features 1 

(1) Abort Delay

 - Program to allow a 15 

second Delay (except  

24 Hour Zones

) after 

a zone trip before reporting.  Disarm the 
system within 15 seconds to prevent 
reporting. 

(2) Easy Exit/Easy Arm

 - Enables 

A

 

0

 

command.  While the system is armed, 
entering this command allows 3 minutes to 
Exit through 

Exit/Entry 

and 

Exit/Entry 

Follower Zones

.  Enabling this option also 

enables Easy Arm,  enter 

a

 

0

 to arm 

the system. 

(3) Swinger Shutdown

 - Automatically 

disables armed zones with excessive alarm/
restores (swingers).  Non-24-Hour 
Protection zones: allows only 3 alarms and 
2 restores per zone per arming before the 
zone is disabled. 

(4) Bell on Line Cut

 (Armed) - Program to 

turn the Bell Output on if the telephone line 
has been cut while the panel is armed. 

 

[23]Programmable Output  Features 1 

(1) Audio Verification

 - Program to activate 

the PGM during reporting.  Select specific 
zones for audio verification by programming 
the required zones in 

PGM Output

  [08],   

PGM Features 2

 [24] and 

PGM Features 3

 

[25].  Connect the PGM to the Veriphone

TM

 

trigger low input.   

(2) Access Output

 - Activates the PGM 

output for 5 seconds using the 

A

 

3

 

command.  

(3) Follow Keypad Sounder

 - The following 

keypad sounds will activate the PGM output:  
Entry Sounder, Keypad Pulsing Sounder,  
Keypad Output on Alarm, Chime, Fault Find. 

(4) Keyfob/Keyswitch Chirp

 - Program to 

chirp the PGM Output (1) one time when the 
panel is armed or (2) two times when the panel 
is disarmed.  Wire as shown in Figure 7. 

 

 

 
 

 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 
 

 

 
 
[24]Programmable Output

 

 Features 2 

(1) 

I

 

Fire

 - Program to activate the PGM 

on a Fire alarm. 

(2) AUX

 - Program to activate the PGM on a 

AUX alarm. 

(3) Panic

 - Program to activate the PGM on 

a Panic alarm. 

(4) Test Timer

 - Program to activate the 

PGM during a Test Timer report. 

 
[25]Programmable Output Features 3 

(1) 

Y

 

AC Fail

 - Program to activate the 

PGM on the loss of AC. (15 minute delay) 

(2) Low Battery 

- Program to activate the 

PGM on a Low Battery condition. 

(3) *Trouble 

- Program to activate the PGM 

on a Trouble condition. 

(4) Armed 

- Program to activate the PGM 

when the panel is Armed.  The PGM output 
will flash when the panel has gone into 
alarm. 

 

*

Includes Bell Cut, Fire Trouble, Receiver 

Fail-to-Respond, Receiver Tamper, 
Receiver JAM, Wireless Smoke Low 
Battery, Wireless Smoke Supervisory Fail. 

 

[26]Miscellaneous Features 2 

(1) Momentary Keyswitch Arming

 - 

Typically, connect a normally-open 
Keyswitch across the zone AND its 3.3K 
zone-doubling resistor. 

(2) Reserved

(3) Inhibit Fail-to-Communicate Display - 

This option prevents the keypad from either 
indicating or sounding when a Fail to 
Communicate has occurred. 

(4) Inhibit Low Battery Display 

- Program 

to inhibit the Low Battery Display at the 
keypad.  Low Battery Reporting is not 
inhibited.  The programming option is not 
permitted for UL installations.  

 

 

 

Telephone Number 1 Programming 

 
[30]Subscriber ID Number 

For 4/2 format enter a 4 digit number.  If 3/1 
format is required, enter a 3 digit number, 

 N/O 

 N/C 

COM

BLK 

RED 

+AUX

 

Siren Driver  
Steady Input 

PGM

+AUX

K1 

FIGURE

 

7

 K

EYFOB

/K

EYSWITCH

 

Содержание RPXP6GT

Страница 1: ...XP 600 RPXP6GT keypad Control Panel Communicator Installation Instructions WI1372 1 05 NAPCO 2005...

Страница 2: ...Line Cut Detection Answering Machine Override Second Call 50 Event Log Communicator 2 Telephone Numbers Backup Reporting Pager Format Point ID Format Individually Report 6 Users Opening after Alarm R...

Страница 3: ...Battery 12V 4 AH Rechargeable Change Battery every 5 years or as required Maximum Charging Current 165 mA Maximum Input Current 2 58 A Loop Characteristics Loop Voltage 5 Volts Loop Current Zones 1 2...

Страница 4: ...ss PIR Wireless Dual Technology Sensor Wireless Glass Break Detector Relay Board Audio Verification Module Downloading Software for IBM PC Compatibles Software with Interface for IBM PC Compatibles in...

Страница 5: ...ng PCPreset For Site Initiated Downloaded see Auto Download ID Number 93 Local Downloading Wire as shown in Figure 1 Use the power up or A6 method of establishing a connection The power up method is r...

Страница 6: ...eat detectors rather than smoke detectors are recommended in kitchens attics and garages due to conditions that may result in false alarms and improper operation Refer to NFPA Standard 74 National Fir...

Страница 7: ...mA Keypad Operation Keypad zone LEDs indicate zone status W ARMED X READY and HSYSTEM LEDs provide system status The keypad sounder provides feedback beeps for correct and incorrect entries Keypad So...

Страница 8: ...y Follower Zones can be bypassed when the M or N keys on the Keyfob have been programmed for Interior 81 84 Zones programmed as Home Away with Delay Zones can be armed regardless of the state of the E...

Страница 9: ...omatic Bypassing Home Away with Delay Zones From the Keypad Press C B to return protection to Home Away with Delay Zones that have been automatically bypassed Three minutes are allowed to walk through...

Страница 10: ...rogram Mode press the b key XP 600 Commands User Commands A 1 Bell Test Enter this command to turn on the Bell keypad sounder and keypad LEDs for 2 seconds The battery is tested during a Bell Test and...

Страница 11: ...ds when hardwired zones are faulted and for 1 second when zones are restored Wireless Operation Signal Strength While in Fault Find mode the keypad will provide an audible Table 6 and visual Figure 5...

Страница 12: ...lows exit after the panel is armed without setting off an immediate alarm and allows entry only if an Exit Entry Zone 00 has been violated first Zones of this type have a three 3 minute power up delay...

Страница 13: ...it through an Exit Entry Zone 00 after the system is armed allows a user to leave the premises without setting off an immediate alarm Exit Delay may be programmed for up to 255 seconds 4 minutes a val...

Страница 14: ...000 Downloading Software On power up the test timer is sent immediately Follow the commands below to offset the test timer using Quickloader Software From the Status Screen Press F6 Select Miscellaneo...

Страница 15: ...armed or 2 two times when the panel is disarmed Wire as shown in Figure 7 24 Programmable Output Features 2 1 I Fire Program to activate the PGM on a Fire alarm 2 AUX Program to activate the PGM on a...

Страница 16: ...orrect data the panel sends a Sumcheck digit after sending the Subscriber ID and Alarm Code 3 Single Digit 3 1 Format 3 digit Subscriber ID number and a 1 digit Alarm Code will be transmitted 4 No Han...

Страница 17: ...icator Enabled Program to enable the communicator 2 DTMF with Rotary Backup The first attempt to communicate is dialed using the TouchTone method of dialing subsequent attempts are dialed using the pu...

Страница 18: ...st digit of the report code sent the second digit is the zone number of the reporting zone For example if zone 2 has a report code of 3 the report code would be 32 3 1 format Sends only the report Cod...

Страница 19: ...de 62 2 is used to report zones that have been bypassed at the time of the closing report 3 Reserved 4 Reserved 68 Telephone Number 3 1 Opening after Alarm Cancel Code see 67 1 2 Conditional Closing T...

Страница 20: ...1 36 2 and or Telco 3 56 3 Audible Panic Optional 21 1 2 AUX Program a 2 in the AUX 1 and or AUX 2 option to initiate a AUX alarm when the M or N buttons on the Keyfob are pressed Additional programm...

Страница 21: ...s 1 Ring Method Enable the ring method of downloading The panel will pick up on the number of rings programmed in Ring Count 91 2 Answering Machine Override Using the downloading computer call the pan...

Страница 22: ...ollowing UL required features There is a 4 hour re sound of wireless Smoke Low Battery and wireless Smoke Supervisory system troubles An active System Battery test performed every 4 hours instead of 2...

Страница 23: ...e keypad will beep once every 10 seconds The keypad will continue to beep until the reset button is pressed or the trouble has been acknowledged by pressing the i key System Trouble Reporting The foll...

Страница 24: ...A signal is blocking the normal reception of transmissions from the wireless devices Ensure that the green LED on the receiver is not on continuously refer to receiver manual WI848 3 Beeps 1 6 Wireles...

Страница 25: ...flowing through the Bell circuit for supervision To eliminate the buzzing cut resistor R26 which is located directly above Terminal 9 just below the heat sink 5 Where are the fuses The control panel...

Страница 26: ...1 and point 2 is jumped out If using internal reed make sure J1 is cut and both Point 1 and Point 2 terminals are jumped out 10 Keypad LEDs Flicker The Keypad is not receiving a POLL from the Panel Ch...

Страница 27: ...Out Power In Fire Loop Out RED BLACK BROWN BROWN FT2200 8 7 8 9 Power In Fire Power Ground Fire Power Fire 2 2K 2 2K Normally Open Zone Wiring Wire the normally open contact as shown Zone 4 Program t...

Страница 28: ...Despite frequent testing and due to but not limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expec...

Отзывы: