background image

Napco iSecure Security System                         

All technical manuals are available in PDF format at 

tech.napcosecurity.com

 

59 

Cloud Web Portal for later retrieval, if needed. 

 

  Restore From Backup 

  Click to restore the iSecure Cloud Web Portal to the previ-

ous  configuration  that  will  appear.    To  update  the  Go-

Anywhere Hub, a full download must be performed after the 

restoral.   

 

  BACKUP Z-Wave Configuration Data 

  Click to back up all Z-Wave enrolled devices and program-

ming into the iSecure Cloud Web Portal. 

 

  RESTORE Z-Wave Configuration Data 

  Click  to  restore  all  Z-Wave  enrolled  devices  and  program-

ming into the Z-Wave device.   

 

  Last backup 

  Displayed under the appropriate button, this is the date and 

time (in 24-hour military format) the last complete and suc-

cessful backup was performed for the associated configura-

tion.    The  backup  is  sent  from  the  Hub  to  the  Cloud  Web 

Portal.   

 

 

ISECURE DEVICE VERSIONS & STATUS 

  Many  different  types  of  microprocessors  and  firmware  are 

used within the iSecure system, some located within the Go

-Anywhere Hub, others within each iSecure device.  Some 

devices are required, some are optional; all are listed in this 

screen to display their related firmware for each.  Use this 

screen  to  ensure  that  the  firmware  is  the  latest  version 

(click the 

Scan

 button to retrieve the latest data).  To manu-

ally update firmware, see the section "

FIRMWARE  DOWN-

LOAD

"  on page 57.  

 

 

 

 

 

 

 

 

 

 

 

 

 

  Entries located at the top of this screen include the various 

Go-Anywhere Hub hardware and firmware versions, includ-

ing:   

 

"

EZ_DATABASE

"   refers  to  the  iSecure  Cloud  Web 

Portal database version.   

 

"

ISECURE  PANEL

"  refers to the microprocessor ver-

sion  within  the  Go-Anywhere  Hub  that  controls  most  of 

the local alarm functions (arming/disarming, etc.).   

 

"

RadioFirmware  Version

"  refers to the microproces-

sor within the Go-Anywhere Hub that controls the radio 

communications  between  the  Hub  and  the  wireless  de-

vice(s).   

 

"

RadioHardware  Version

"  refers to the version of the 

LTE  Radio  PC  board 

that  is  plugged  into  the  Go-

Anywhere  Hub  motherboard.    This  PCB  controls  the 

LTE radio communication (reporting) functions.   

Other iSecure Cloud Web Portal Screens (cont'd)  

 

INTEGRAL KEYPAD

 (reserved for future use) 

 

RF  RECEIVERS1

  refers  to  the  integral  Hub  319MHz 

receiver  firmware  that  controls  those  devices,  including 

the  window/door  transmitters,  passive  infrared  motion 

sensors, etc. 

 

RF  RECEIVERS2

  refers  to  the  integral  Hub  900MHz 

receiver  firmware  that  controls  those  devices,  including 

the keypads and other 900MHz peripherals. 

 

  Other entries include the versions and current status of the 

various  optional  iSecure  devices  that  can  be  added  to  the 

system (sirens, keypads, sensors, etc.).   

 

  Device Name / Device Type 

  Description of each upgradable module or firmware version 

that exists or can exist within the iSecure system.  The text 

names are derived from the current Hub firmware.   

 

  M1 Version / Boot Loader / M2 Version 

  Displays  the  version  of  the  Hub  firmware  for  microproces-

sor #1 and (under its own column) #2.  The Boot Loader is 

the firmware that controls the remote download/upload pro-

cesses.   

 

  RFID 

  Each wireless device (for example, a keypad) has a unique 

factory programmed ID code that distinguishes itself to the 

Hub.  For example, "155E57:F".  The first six characters of 

the ID code are displayed here.   

 

  Learn Status 

  Indicates whether the device was correctly and successfully 

entered  into  the  Hub  programming.   

Note: 

  Although  the 

device  may  be  been  correctly  configured  in  the  iSecure 

Cloud  Web  Portal  and  downloaded  into  the  Go-Anywhere 

Hub  without  apparent  errors,  a  "Learn  Successful"  status 

always  requires  a  complete  two-way  synchronization  and 

acknowledgement  "handshake"  between  the  Hub  and  the 

device.  For example, a device with a "Learn Unsuccessful" 

status  may  not  have  been  powered  during  the  learn  pro-

cess, and thus is not successfully learned into the system.  

Note:

    Every  re-learn  process  also  refreshes  the  version 

information. 

  See "

FIRMWARE DOWNLOAD

" on page 57 for important 

information about the firmware update process.   

Содержание iSecure ISEC-EXTANT-KIT

Страница 1: ...arefully separate the two parts of the Hub housing Note Separating the housing disconnects the battery 3 Remove the top screw at the top of the unit that se cures the front LED Faceplate to the front...

Страница 2: ...ose the two parts of the Hub housing routing the cable out the rear access door see Fig 9 Be sure not to crimp the wire between the PCB and the housing Closing the two parts of the Hub housing will re...

Страница 3: ...Receiver trouble due to excessive radio noise in area Try relocating the Smart Hub Otherwise call for service Rapid Flicker Transmissions in progress Flashing 900MHZ peripheral download Status Off No...

Страница 4: ...e ISEC WL TOUCH press and hold the appropri ate FIRE AUX or PANIC button respectively see the Us er s Guide for details By default Emergency Buttons are enabled for all keypads to disallow their use s...

Страница 5: ...R FUNCTION Select Instant or Interior When armed STAY usually when sleeping and you want the motion to ignore movement within the home select Interior If you want the sensor to immediately trigger an...

Страница 6: ...it sensor ID for the device 4 DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display AREA Default 1 See the key pad Operating Guide for the definition of Area SENSOR FUNCTIO...

Страница 7: ...sor For example use for an interior door that will be in use when armed STAY but protected when armed AWAY Instant Allows for an immediate alarm when activated providing instant protection while you o...

Страница 8: ...ON Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Smoke Sensor SENSOR FUNCTION Smoke is automatically selected when Smoke Sen sor is select ed as the SENSOR T...

Страница 9: ...on the keypad display SENSOR TYPE Select Heat Sensor SENSOR FUNCTION Heat is auto matically select ed when Heat Sensor is se lected as the SENSOR TYPE SENSOR ID Type in the 7 digit sen sor ID for the...

Страница 10: ...or DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Carbon Monoxide SENSOR FUNCTION CO Alarm is automatically selected when Carbon Mon oxide is se l...

Страница 11: ...the following Instant Allows for an immediate alarm when the panic button is pressed providing instant protection 24Hr Zone Audible Provides protection at all times whether or not the sys tem is armed...

Страница 12: ...e Select to disable the designated key Key 3 and or Key 4 Panic Pressing the designated key causes the siren to sound and sends a panic report to the central station Instant Pressing the designated ke...

Страница 13: ...wered by an AC power supply plugged into a 120VAC unswitched wall outlet or with batteries Select the power type used by your siren NAME Type the siren description you wish to appear on the keypad dis...

Страница 14: ...ired zone to the RF ID of the supervised 900MHz wireless zone up to 8 zones for each ISEC WL MODULE In the TAKEOVER screen shown below for the Takeover Module added previously program each column as d...

Страница 15: ...mn 3 To add a new Code click in a blank USER CODES field and enter the new User Code up to 6 digits To erase or change an existing Code simply clear or re enter the User Code 4 Add a check to either o...

Страница 16: ...Download Security Code for all accounts When attempting to establish a connection if this code is forgotten the Master Security Code of the particular Go Anywhere Hub can be used in its place Dealer K...

Страница 17: ...e system installation Video Security Z Wave Remote Access Check to enable access to each service from the Home Screen of the IBR TOUCH WL Smart 7 Wireless IoT Touchscreen Check Remote Access to allow...

Страница 18: ...be needed Users Displays the USER ID NAME EMAIL address of those who can log into the iSecure Cloud Web Portal MASTER is checked for those users authorized to make all changes to the account without...

Страница 19: ...ardware Version refers to the version of the LTE Radio PC board that is plugged into the Go Anywhere Hub motherboard This PCB controls the LTE radio communication reporting functions Other iSecure Clo...

Страница 20: ...relocate the Go Anywhere Smart Hub or the device so they are in closer proximity E 05 NN Transmitter Low Battery When an RF device has a weak battery an error E 05 appears The NN is a two digit number...

Отзывы: