background image

42 

All technical manuals are available in PDF format at 

tech.napcosecurity.com

                         Napco iSecure Security System

 

Install the ISEC-EXTANT-KIT (cont'd) 

10.

 

Route  the  cable  through  the  Hub 

and  along  the 

pathway shown in Fig. 6.  Guide the cable to the right 

and  around  the  side  "ribs"  shown  in  Fig.  7  and  down 

along the bottom of the Hub PC board.  

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Important:

    To  ensure  maximum  reception  perfor-

mance, the cable 

must 

be routed along this path.   

 

11. For  strain  relief

,  secure  the  cable  to  the  PCB  by 

inserting the zip tie into the PCB hole shown in Fig. 8.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Before  proceeding

, be sure the 

SLE-ANTEXT

 anten-

na  is  connected  to  allow  its  immediate  use  when  the 

radio is re-powered in the next step. 

 

12. Close the two parts of the Hub housing, routing the 

cable 

out the rear access door (see Fig. 9).  Be sure 

not to crimp the wire between the PCB and the housing.   

 

 

Closing  the  two  parts  of  the  Hub  housing  will  re-power 

the  unit,  and  the  antenna  will  immediately  begin  trans-

mitting.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13. Re-connect  AC  power  to  the  Go-Anywhere  Smart 

Hub

  by  plugging  in  the  AC  transformer.    Test  sys-

tem operation.   

Fig. 8:  For strain relief, secure antenna cable to the PCB with zip tie 

Fig. 6:  Route the Antenna Cable to the right of the side "ribs" 

as shown in this image and in Fig. 7.   

Fig. 7:  Route the cable around the side "ribs" (arrows) as shown. 

Fig. 9:  Route cable through access door.  With access door in-

stalled, route cable through the opening in the bottom of the 

door. 

Exit here 

Exit here 

Fig. 5:  Verizon and AT&T Antenna Socket Locations 

For 

Verizon 

PCBs: 

Use socket 

J502

  

L

T

E

    

V

E

RIZ
O

N

 

For 

AT&T 

PCBs:   

Use socket "

MAIN RF

Содержание iSecure ISEC-EXTANT-KIT

Страница 1: ...arefully separate the two parts of the Hub housing Note Separating the housing disconnects the battery 3 Remove the top screw at the top of the unit that se cures the front LED Faceplate to the front...

Страница 2: ...ose the two parts of the Hub housing routing the cable out the rear access door see Fig 9 Be sure not to crimp the wire between the PCB and the housing Closing the two parts of the Hub housing will re...

Страница 3: ...Receiver trouble due to excessive radio noise in area Try relocating the Smart Hub Otherwise call for service Rapid Flicker Transmissions in progress Flashing 900MHZ peripheral download Status Off No...

Страница 4: ...e ISEC WL TOUCH press and hold the appropri ate FIRE AUX or PANIC button respectively see the Us er s Guide for details By default Emergency Buttons are enabled for all keypads to disallow their use s...

Страница 5: ...R FUNCTION Select Instant or Interior When armed STAY usually when sleeping and you want the motion to ignore movement within the home select Interior If you want the sensor to immediately trigger an...

Страница 6: ...it sensor ID for the device 4 DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display AREA Default 1 See the key pad Operating Guide for the definition of Area SENSOR FUNCTIO...

Страница 7: ...sor For example use for an interior door that will be in use when armed STAY but protected when armed AWAY Instant Allows for an immediate alarm when activated providing instant protection while you o...

Страница 8: ...ON Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Smoke Sensor SENSOR FUNCTION Smoke is automatically selected when Smoke Sen sor is select ed as the SENSOR T...

Страница 9: ...on the keypad display SENSOR TYPE Select Heat Sensor SENSOR FUNCTION Heat is auto matically select ed when Heat Sensor is se lected as the SENSOR TYPE SENSOR ID Type in the 7 digit sen sor ID for the...

Страница 10: ...or DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Carbon Monoxide SENSOR FUNCTION CO Alarm is automatically selected when Carbon Mon oxide is se l...

Страница 11: ...the following Instant Allows for an immediate alarm when the panic button is pressed providing instant protection 24Hr Zone Audible Provides protection at all times whether or not the sys tem is armed...

Страница 12: ...e Select to disable the designated key Key 3 and or Key 4 Panic Pressing the designated key causes the siren to sound and sends a panic report to the central station Instant Pressing the designated ke...

Страница 13: ...wered by an AC power supply plugged into a 120VAC unswitched wall outlet or with batteries Select the power type used by your siren NAME Type the siren description you wish to appear on the keypad dis...

Страница 14: ...ired zone to the RF ID of the supervised 900MHz wireless zone up to 8 zones for each ISEC WL MODULE In the TAKEOVER screen shown below for the Takeover Module added previously program each column as d...

Страница 15: ...mn 3 To add a new Code click in a blank USER CODES field and enter the new User Code up to 6 digits To erase or change an existing Code simply clear or re enter the User Code 4 Add a check to either o...

Страница 16: ...Download Security Code for all accounts When attempting to establish a connection if this code is forgotten the Master Security Code of the particular Go Anywhere Hub can be used in its place Dealer K...

Страница 17: ...e system installation Video Security Z Wave Remote Access Check to enable access to each service from the Home Screen of the IBR TOUCH WL Smart 7 Wireless IoT Touchscreen Check Remote Access to allow...

Страница 18: ...be needed Users Displays the USER ID NAME EMAIL address of those who can log into the iSecure Cloud Web Portal MASTER is checked for those users authorized to make all changes to the account without...

Страница 19: ...ardware Version refers to the version of the LTE Radio PC board that is plugged into the Go Anywhere Hub motherboard This PCB controls the LTE radio communication reporting functions Other iSecure Clo...

Страница 20: ...relocate the Go Anywhere Smart Hub or the device so they are in closer proximity E 05 NN Transmitter Low Battery When an RF device has a weak battery an error E 05 appears The NN is a two digit number...

Отзывы: