background image

56 

All technical manuals are available in PDF format at 

tech.napcosecurity.com

                         Napco iSecure Security System

 

merely disarming the system.  Add a check to enable 

Report  Am-

bush

, and the Ambush Zone will automatically report.  

Note: 

 

The 

Ambush  Prefix

 is a 2-digit code that is entered immediately 

prior to (and as part of) a regular valid User Code.  

Important:

  Do 

not  program  the  first  two  digits  of  ANY  User  Code  as  the  same 

digits entered for the "

Ambush Prefix

". 

 

  Report Troubles 

  Report Arm or Disarm 

  Disable ALL Reporting 

  Check 

Report  Troubles

 to allow all system troubles to be reported 

to the central station.  If 

Report Troubles 

is unchecked and 

Report 

Arm  or  Disarm

  is  checked,  only  arm/disarm  events  will  be 

reported  to  the  central  station.    If 

Disable  ALL  Reporting

  is 

checked, all central station reporting will be stopped.   

 

  Enable Base Unit Siren 

  Check  to  enable  (and  uncheck  to  silence)  the  Go-Anywhere 

Smart Hub sounder and speaker (enabled by default).   

 

  Disable Audible System Trouble 

  Unchecked by default, add a check to silence all audible system 

trouble notifications at the Hub and at all keypads.   

 

  Master Security Code

   

  This code is added to the Go-Anywhere Hub memory at the facto-

ry and is not changeable.  This code is printed on a label placed 

on a card (OI404LF) that is included with the Go-Anywhere Hub.  

Entering  this  code  at  a  keypad  will  provide  access  to  ALL  func-

tions in the system.  This code MUST be entered in this field and 

must match the code at the corresponding Hub.  

Note: 

 All keypad 

programming  must  be  performed  at  the  keypad  addressed  as 

Keypad # 1.  Retain the OI404LF card with the code in a secure 

place for reference.  

Note:

  Whenever you add or update the Mas-

ter Security Code, you must log out and log back into the applica-

tion (exiting and re-entering ensures that the iSecure Cloud Web 

Portal  and  the  Master  Security  Code  are  synchronized  and  the 

system is fully protected by your secure account password).   

 

  Download Security Code 

  This code is not a keypad code, but is only used to permit local or 

remote connections to be established between the iSecure Cloud 

Web Portal and the Go-Anywhere Hub.  Used during the connec-

tion  process,  if  the  code  stored  in  the  Hub  does  not  match  the 

code entered here (in the iSecure Cloud Web Portal), a data con-

nection will be denied.  Some dealers with multiple iSecure Cloud 

Web Portal accounts use the same Download Security Code for 

all  accounts.    When  attempting  to  establish  a  connection,  if  this 

code is forgotten, the Master Security Code of the particular Go-

Anywhere Hub can be used in its place. 

 

  Dealer Keypad Programming Code 

  This code is left blank in the Hub memory at the factory and may 

be  added  by  the  dealer  (in  possession  of  the 

Master  Security 

Code

).    The 

Dealer  Keypad  Programming  Code

  allows  the 

same  access  to  programming  functions  as  the 

Master  Security 

Code

.   

 

  Bell Supervision 

  If checked, the Bell output, supervised with an EOLR, if shorted or 

opened the keypad will display an E51 trouble, with a report sent 

to the central station.   

 

  Auto Reset Trouble Disable 

  If this feature is checked (where "auto reset" is to be "disabled"), if 

the  system  detects  a  trouble  and  its  condition  is  subsequently 

GENERAL SETTINGS 

  Various  system  settings  are  available,  including  those  to  control 

system  delays,  timeouts,  reporting  and  special  system  security 

codes.  Each is described below. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Entry Delay 1 

  Entry Delay 2 

  Exit Delay 

  Separate delays that let you exit and enter your premises without 

setting off an alarm when the system is armed.  The iSecure sys-

tem has three programmable Entry Delay times available:  30, 45 

and  60  seconds  (default  is  30  seconds).    Exit  Delay  available 

times are 45, 60 and 90 seconds (default is 45 seconds).   

 

  Door Chime Duration 

  When Door Chime is enabled, a beep will sound while the system 

is disarmed to alert that the programmed zone (for example, an 

Entry Door) has been opened.  Available times are 1, 1.5 and 2 

seconds.   

 

  Alarm Siren Timeout 

  Fire Siren Timeout 

  Duration  the  siren  will  remain  active  (ON)  unless  the  system  is 

reset or silenced with a code entry.  

 

  Sensor Supv. Timeout 

  Specifies the length of time before a 319MHz transmitter supervi-

sory  trouble  is  triggered  if  no  transmission  is  received  from  the 

transmitter.    The  default 

Sensor  Supv.  Timeout 

upon  a  Go-

Anywhere Hub Cold Start is "Undefined", but available selections 

are 4 and 24 hours.   

 

  Enable Remote Hardwired Receiver 

 

  Add a check to allow the use of a GEMWV-RECV wireless receiv-

er  in  the  system.    With  2  integral  Hub  receivers,  this  additional 

receiver would make a system total of 3.  See the installation in-

structions  supplied  with  the  GEMWV-RECV  (WI2316)  to  config-

ure the receiver jumpers to enable the GEMWV-RECV as receiv-

er #3.   

 

  Report Ambush 

  Ambush Prefix 

  Disarming with an Ambush Code will cause a silent report to be 

sent to a central station.  Thus, should a user be forced to disarm, 

the user can silently signal an emergency while appearing to be 

Other iSecure Cloud Web Portal Screens 

Содержание iSecure ISEC-EXTANT-KIT

Страница 1: ...arefully separate the two parts of the Hub housing Note Separating the housing disconnects the battery 3 Remove the top screw at the top of the unit that se cures the front LED Faceplate to the front...

Страница 2: ...ose the two parts of the Hub housing routing the cable out the rear access door see Fig 9 Be sure not to crimp the wire between the PCB and the housing Closing the two parts of the Hub housing will re...

Страница 3: ...Receiver trouble due to excessive radio noise in area Try relocating the Smart Hub Otherwise call for service Rapid Flicker Transmissions in progress Flashing 900MHZ peripheral download Status Off No...

Страница 4: ...e ISEC WL TOUCH press and hold the appropri ate FIRE AUX or PANIC button respectively see the Us er s Guide for details By default Emergency Buttons are enabled for all keypads to disallow their use s...

Страница 5: ...R FUNCTION Select Instant or Interior When armed STAY usually when sleeping and you want the motion to ignore movement within the home select Interior If you want the sensor to immediately trigger an...

Страница 6: ...it sensor ID for the device 4 DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display AREA Default 1 See the key pad Operating Guide for the definition of Area SENSOR FUNCTIO...

Страница 7: ...sor For example use for an interior door that will be in use when armed STAY but protected when armed AWAY Instant Allows for an immediate alarm when activated providing instant protection while you o...

Страница 8: ...ON Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Smoke Sensor SENSOR FUNCTION Smoke is automatically selected when Smoke Sen sor is select ed as the SENSOR T...

Страница 9: ...on the keypad display SENSOR TYPE Select Heat Sensor SENSOR FUNCTION Heat is auto matically select ed when Heat Sensor is se lected as the SENSOR TYPE SENSOR ID Type in the 7 digit sen sor ID for the...

Страница 10: ...or DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Carbon Monoxide SENSOR FUNCTION CO Alarm is automatically selected when Carbon Mon oxide is se l...

Страница 11: ...the following Instant Allows for an immediate alarm when the panic button is pressed providing instant protection 24Hr Zone Audible Provides protection at all times whether or not the sys tem is armed...

Страница 12: ...e Select to disable the designated key Key 3 and or Key 4 Panic Pressing the designated key causes the siren to sound and sends a panic report to the central station Instant Pressing the designated ke...

Страница 13: ...wered by an AC power supply plugged into a 120VAC unswitched wall outlet or with batteries Select the power type used by your siren NAME Type the siren description you wish to appear on the keypad dis...

Страница 14: ...ired zone to the RF ID of the supervised 900MHz wireless zone up to 8 zones for each ISEC WL MODULE In the TAKEOVER screen shown below for the Takeover Module added previously program each column as d...

Страница 15: ...mn 3 To add a new Code click in a blank USER CODES field and enter the new User Code up to 6 digits To erase or change an existing Code simply clear or re enter the User Code 4 Add a check to either o...

Страница 16: ...Download Security Code for all accounts When attempting to establish a connection if this code is forgotten the Master Security Code of the particular Go Anywhere Hub can be used in its place Dealer K...

Страница 17: ...e system installation Video Security Z Wave Remote Access Check to enable access to each service from the Home Screen of the IBR TOUCH WL Smart 7 Wireless IoT Touchscreen Check Remote Access to allow...

Страница 18: ...be needed Users Displays the USER ID NAME EMAIL address of those who can log into the iSecure Cloud Web Portal MASTER is checked for those users authorized to make all changes to the account without...

Страница 19: ...ardware Version refers to the version of the LTE Radio PC board that is plugged into the Go Anywhere Hub motherboard This PCB controls the LTE radio communication reporting functions Other iSecure Clo...

Страница 20: ...relocate the Go Anywhere Smart Hub or the device so they are in closer proximity E 05 NN Transmitter Low Battery When an RF device has a weak battery an error E 05 appears The NN is a two digit number...