background image

58 

All technical manuals are available in PDF format at 

tech.napcosecurity.com

                         Napco iSecure Security System

 

  Allow Subscriber to Update User Codes? 

  Click  the 

Yes 

or 

No 

radio  buttons  to  allow  or  disallow  the 

homeowner  (user)  the  ability  to  add/change/review  User 

Codes using the touchscreen (in Notification Setup only).   

 

  Allow Subscriber to Update Zone Descriptions? 

  Click  the 

Yes 

or 

No 

radio  buttons  to  allow  or  disallow  the 

homeowner  (user)  the  ability  to  change  Zone  Description 

text using the touchscreen (in Notification Setup only).   

 

  Allow Subscriber to program Z-Wave? 

  (Appears if installed)  Click the 

Yes 

or 

No 

radio buttons to 

allow or disallow the user the ability to add and program Z-

Wave  home  automation  devices.    For  more  information 

about  using  Z-Wave  with  your  iSecure  system,  see 

OI414LF, available for download at 

tech.napcosecurity.com

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Notifications Enabled? 

  Click the 

Yes 

or 

No 

radio buttons to allow or disallow notifi-

cation messages for this account.    

 

  Notifications Server IP Address 

  Displays the IP address of the server used to send notifica-

tion messages for this account.   

 

  Export MAC Address 

 

Note:

    In  addition  to  standard  security  passwords, 

some wireless routers can also be configured to allow Wi-Fi 

connections to only specific MAC Addresses.  Displays the 

MAC Address of the Go-Anywhere Hub in an easy-to-copy 

field, should it be needed.   

 

  Users 

  Displays  the 

USER  ID

NAME

EMAIL 

address  of  those 

who can log into the iSecure Cloud Web Portal.  

MASTER 

is checked for those users authorized to make all changes 

to  the  account  without  restrictions.    Click 

Reset  Password 

to edit the password of the selected User.   

 

 

PANEL EVENT HISTORY 

  Displays  800  of  the  most  recent  Hub  events  of  all  types, 

including  alarm  conditions,  Fire  events,  and  openings  / 

closings  (see  example,  above).    Includes  the  event,  date, 

Other iSecure Cloud Web Portal Screens (cont'd)  

time,  Area,  zone,  User  Code  and  other  pertinent  infor-

mation,  where  necessary,  depending  upon  event.    When 

the number of events reaches the 800 maximum, the oldest 

events are overwritten. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPLOAD / DOWNLOAD  

SAVE / RESTORE 

  After  making  changes  within  the  various  iSecure  Cloud 

Web Portal screens, click the 

Upload  /  Download  /  Save  / 

Restore

 button to upload (i.e. back up) the existing Hub 

programming  into  the  Cloud  Web  Portal,  or  send  your 

changes to the Go-Anywhere Hub.   

 

  Download All Changes 

  Downloads  all  changes 

made  in  the  iSecure 

Cloud  Web  Portal  into 

the Go-Anywhere Hub. 

 

  Full Download 

  Performs  a full  download 

from  the  changes  made 

in the iSecure Cloud Web 

Portal  and  overwrites 

ALL configuration data in 

the Go-Anywhere Hub.   

 

  Upload 

Settings 

to 

Cloud 

  Performs  a  full  upload  of 

all  configuration  data  in 

the  Go-Anywhere  Hub 

and overwrites any exist-

ing  configuration  data  in 

the  iSecure  Cloud  Web 

Portal. 

 

  Create Restore Point 

  Creates  a  copy  of  the 

current  iSecure  Configu-

ration data already in the 

iSecure  Cloud  Web  Por-

tal  and  retains  it  in  the 

Содержание iSecure ISEC-EXTANT-KIT

Страница 1: ...arefully separate the two parts of the Hub housing Note Separating the housing disconnects the battery 3 Remove the top screw at the top of the unit that se cures the front LED Faceplate to the front...

Страница 2: ...ose the two parts of the Hub housing routing the cable out the rear access door see Fig 9 Be sure not to crimp the wire between the PCB and the housing Closing the two parts of the Hub housing will re...

Страница 3: ...Receiver trouble due to excessive radio noise in area Try relocating the Smart Hub Otherwise call for service Rapid Flicker Transmissions in progress Flashing 900MHZ peripheral download Status Off No...

Страница 4: ...e ISEC WL TOUCH press and hold the appropri ate FIRE AUX or PANIC button respectively see the Us er s Guide for details By default Emergency Buttons are enabled for all keypads to disallow their use s...

Страница 5: ...R FUNCTION Select Instant or Interior When armed STAY usually when sleeping and you want the motion to ignore movement within the home select Interior If you want the sensor to immediately trigger an...

Страница 6: ...it sensor ID for the device 4 DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display AREA Default 1 See the key pad Operating Guide for the definition of Area SENSOR FUNCTIO...

Страница 7: ...sor For example use for an interior door that will be in use when armed STAY but protected when armed AWAY Instant Allows for an immediate alarm when activated providing instant protection while you o...

Страница 8: ...ON Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Smoke Sensor SENSOR FUNCTION Smoke is automatically selected when Smoke Sen sor is select ed as the SENSOR T...

Страница 9: ...on the keypad display SENSOR TYPE Select Heat Sensor SENSOR FUNCTION Heat is auto matically select ed when Heat Sensor is se lected as the SENSOR TYPE SENSOR ID Type in the 7 digit sen sor ID for the...

Страница 10: ...or DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Carbon Monoxide SENSOR FUNCTION CO Alarm is automatically selected when Carbon Mon oxide is se l...

Страница 11: ...the following Instant Allows for an immediate alarm when the panic button is pressed providing instant protection 24Hr Zone Audible Provides protection at all times whether or not the sys tem is armed...

Страница 12: ...e Select to disable the designated key Key 3 and or Key 4 Panic Pressing the designated key causes the siren to sound and sends a panic report to the central station Instant Pressing the designated ke...

Страница 13: ...wered by an AC power supply plugged into a 120VAC unswitched wall outlet or with batteries Select the power type used by your siren NAME Type the siren description you wish to appear on the keypad dis...

Страница 14: ...ired zone to the RF ID of the supervised 900MHz wireless zone up to 8 zones for each ISEC WL MODULE In the TAKEOVER screen shown below for the Takeover Module added previously program each column as d...

Страница 15: ...mn 3 To add a new Code click in a blank USER CODES field and enter the new User Code up to 6 digits To erase or change an existing Code simply clear or re enter the User Code 4 Add a check to either o...

Страница 16: ...Download Security Code for all accounts When attempting to establish a connection if this code is forgotten the Master Security Code of the particular Go Anywhere Hub can be used in its place Dealer K...

Страница 17: ...e system installation Video Security Z Wave Remote Access Check to enable access to each service from the Home Screen of the IBR TOUCH WL Smart 7 Wireless IoT Touchscreen Check Remote Access to allow...

Страница 18: ...be needed Users Displays the USER ID NAME EMAIL address of those who can log into the iSecure Cloud Web Portal MASTER is checked for those users authorized to make all changes to the account without...

Страница 19: ...ardware Version refers to the version of the LTE Radio PC board that is plugged into the Go Anywhere Hub motherboard This PCB controls the LTE radio communication reporting functions Other iSecure Clo...

Страница 20: ...relocate the Go Anywhere Smart Hub or the device so they are in closer proximity E 05 NN Transmitter Low Battery When an RF device has a weak battery an error E 05 appears The NN is a two digit number...

Отзывы: