background image

Napco iSecure Security System                         

All technical manuals are available in PDF format at 

tech.napcosecurity.com

 

47 

Programming:  Window / Door Transmitters 

1.  Go to 

www.iSecureByNapco.com

 and log into your 

iSecure account. 

 

2.  Click 

Sensor Configuration

 

3.  In the 

SENSOR CONFIGURATION 

screen (shown 

below), program the installed transmitters as indicat-

ed (when finished, click 

Save

). 

ISEC-DW-XMITTER  Window / Door Transmitter 

DESCRIPTION 

Type the sensor descrip-

tion you wish to appear 

on the keypad display 

SENSOR TYPE  

Select "

Door 

Window

". 

SENSOR ID 

Type in the 7 

digit sensor 

ID # for the 

device 

ENABLE REPORTING 

 

Check to enable cen-

tral station reporting 

SENSOR FUNCTION 

Exit/Entry  1  &  2:

  Allows for exit delay (when leaving the premises) and entry delay 

(when  entering)  before  triggering  an  alarm.    One  of  two  separate  exit/entry  combina-

tions can be selected.   

Interior:

    Use  when  armed  "

STAY

"   (usually  at  night  when  sleeping),  and  you  want 

the system to ignore this sensor.  For example, use for an interior door that will be in 

use when armed "

STAY

" but protected when armed "

AWAY

".   

Instant:

  Allows for an immediate alarm when activated, providing instant protection 

while you or someone else is in the premises. 

24Hr  Zone  Audible:

  Provides protection at all times, whether or not the system is 

armed, by sounding an alarm when the door or window is opened. 

24Hr  Zone  Silent:

    Provides  protection  at  all  times,  whether  or  not  the  system  is 

armed.  When armed and the door or window is opened, a silent alarm will be sent to 

the central station. 

Audible  Panic:

  Triggers the siren  to immediately sound and  an emergency report 

sent to the central station.  

Silent  Panic:

  Triggers a silent report to be sent to the central station (i.e. the user 

can silently signal an emergency).   

SIGNAL STRENGTH 

Relative intensity of 

the last transmission, 

on a scale of 1-10 (10 

being the strongest).  

Note:

  A reading of 3 

or less indicates re-

ception may be errat-

ic; relocate the sensor 

closer to the Hub. 

AREA 

Default = 1.  See the keypad 

Operating Guide for the defini-

tion of "Area". 

CHIME 

Check  to  sound  a  chime  when 

a door (or window) is opened in 

an unarmed system.

 

Содержание iSecure ISEC-EXTANT-KIT

Страница 1: ...arefully separate the two parts of the Hub housing Note Separating the housing disconnects the battery 3 Remove the top screw at the top of the unit that se cures the front LED Faceplate to the front...

Страница 2: ...ose the two parts of the Hub housing routing the cable out the rear access door see Fig 9 Be sure not to crimp the wire between the PCB and the housing Closing the two parts of the Hub housing will re...

Страница 3: ...Receiver trouble due to excessive radio noise in area Try relocating the Smart Hub Otherwise call for service Rapid Flicker Transmissions in progress Flashing 900MHZ peripheral download Status Off No...

Страница 4: ...e ISEC WL TOUCH press and hold the appropri ate FIRE AUX or PANIC button respectively see the Us er s Guide for details By default Emergency Buttons are enabled for all keypads to disallow their use s...

Страница 5: ...R FUNCTION Select Instant or Interior When armed STAY usually when sleeping and you want the motion to ignore movement within the home select Interior If you want the sensor to immediately trigger an...

Страница 6: ...it sensor ID for the device 4 DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display AREA Default 1 See the key pad Operating Guide for the definition of Area SENSOR FUNCTIO...

Страница 7: ...sor For example use for an interior door that will be in use when armed STAY but protected when armed AWAY Instant Allows for an immediate alarm when activated providing instant protection while you o...

Страница 8: ...ON Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Smoke Sensor SENSOR FUNCTION Smoke is automatically selected when Smoke Sen sor is select ed as the SENSOR T...

Страница 9: ...on the keypad display SENSOR TYPE Select Heat Sensor SENSOR FUNCTION Heat is auto matically select ed when Heat Sensor is se lected as the SENSOR TYPE SENSOR ID Type in the 7 digit sen sor ID for the...

Страница 10: ...or DESCRIPTION Type the sensor descrip tion you wish to appear on the keypad display SENSOR TYPE Select Carbon Monoxide SENSOR FUNCTION CO Alarm is automatically selected when Carbon Mon oxide is se l...

Страница 11: ...the following Instant Allows for an immediate alarm when the panic button is pressed providing instant protection 24Hr Zone Audible Provides protection at all times whether or not the sys tem is armed...

Страница 12: ...e Select to disable the designated key Key 3 and or Key 4 Panic Pressing the designated key causes the siren to sound and sends a panic report to the central station Instant Pressing the designated ke...

Страница 13: ...wered by an AC power supply plugged into a 120VAC unswitched wall outlet or with batteries Select the power type used by your siren NAME Type the siren description you wish to appear on the keypad dis...

Страница 14: ...ired zone to the RF ID of the supervised 900MHz wireless zone up to 8 zones for each ISEC WL MODULE In the TAKEOVER screen shown below for the Takeover Module added previously program each column as d...

Страница 15: ...mn 3 To add a new Code click in a blank USER CODES field and enter the new User Code up to 6 digits To erase or change an existing Code simply clear or re enter the User Code 4 Add a check to either o...

Страница 16: ...Download Security Code for all accounts When attempting to establish a connection if this code is forgotten the Master Security Code of the particular Go Anywhere Hub can be used in its place Dealer K...

Страница 17: ...e system installation Video Security Z Wave Remote Access Check to enable access to each service from the Home Screen of the IBR TOUCH WL Smart 7 Wireless IoT Touchscreen Check Remote Access to allow...

Страница 18: ...be needed Users Displays the USER ID NAME EMAIL address of those who can log into the iSecure Cloud Web Portal MASTER is checked for those users authorized to make all changes to the account without...

Страница 19: ...ardware Version refers to the version of the LTE Radio PC board that is plugged into the Go Anywhere Hub motherboard This PCB controls the LTE radio communication reporting functions Other iSecure Clo...

Страница 20: ...relocate the Go Anywhere Smart Hub or the device so they are in closer proximity E 05 NN Transmitter Low Battery When an RF device has a weak battery an error E 05 appears The NN is a two digit number...

Отзывы: