LIBRA LIB-P432EX Series Programming Instructions
NAPCO Security Systems
Page 14
PROGRAM THE DATA ENTRIES
1. Enter the panel's Dealer Security Code, then press
w
.
2. Answer NO ("
X
" or
q
) to all questions until "
ACTIVATE PROGRAM Y/N
" is displayed; then press YES ("
r
" or
p
).
NOTE:
If you pass "
ACTIVATE PROGRAM
", scroll backward using
x
.
3. Press
y
to enter the Address Program Mode. Address "
0000
" will display.
4. Press
1418
to access Address 1418.
The existing data will display and the cursor will advance
to the data field.
5. Since you wish the timeout to be for 2 seconds (and 8 multiplied by ¼ second equals 2 seconds), press
08
. The numbers 08 will appear on the keypad display indicating the number of seconds entered.
6. Press
u
to save. Address 1418 is now programmed with a 2-second chime.
7. Press
w
and enter another 4-digit address to continue programming --or-- press
y
to exit and resume
normal keypad operation.
PROGRAMMING CONVENTIONS USED IN THIS MANUAL
The Keypad Programming Worksheets in the back are provided as an address-programming reference to help the in-
staller modify his custom default program or to make minor field alterations to an existing panel program. It is recom-
mended that the panel be uploaded to NAPCO's PCD-Windows software following any keypad programming and that
the PCD-Windows's error-check feature be utilized to reduce the possibility of programming omissions or conflicts.
3
Keep the Keypad Programming Worksheets on file for future reference.
General Programming Steps
1. Contact the central station to ascertain receiver format, data format, event codes, subscriber numbers and tele-
phone number(s).
2. Select the desired features by circling the respective "address" boxes. Refer to the Programming Options and
Worksheets for guidance in selecting the "data" to be entered into those boxes.
3. Program the data entered in the boxes on the worksheets into the respective addresses. The display will show
the entry numerically, but if hexadecimal format will display "0" for the number 10, and letters "B", "C", "D", "E", and
"F" for the numbers 11 through 15, respectively. To program a 10, press
G0
. To program 11 through 15,
press
G1
through
G5
, respectively.
The displays will appear after a brief delay.
Use
w
to toggle the cursor between the 4-digit address field and the data entry locations.
Enter the address directly using the number buttons.
The contents of the address will be read automatically. The cursor will advance to the data field. Enter the re-
quired data directly using the number buttons.
IMPORTANT:
Press
u
to save the contents of each address.
EXIT DIRECT ADDRESS PROGRAM MODE:
When done, press
y
to exit and resume normal keypad operation.
Содержание GEM-DXK1
Страница 56: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 56 LIB P432EX WIRING DIAGRAM...
Страница 57: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 57 LIB P432EXT WIRING DIAGRAM...
Страница 58: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 58 LIB P432EXT 230 WIRING DIAGRAM...
Страница 59: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 59 NOTES...