NAPCO Security Systems
LIBRA LIB-P432EX Series Programming Instructions
Page 19
SYSTEM OPTIONS (ADDRESS 1420-1424, 2051-2054)
FOOTNOTES
*Address 1423: Default depends on Easy Menu Question :"
EZ ZONE
DOUBLING? Y/N
". If yes, then [Default = 1]. If no, then [Default =
blank (•)].
**To select "Line-Fault Test only when Armed", you must also select
"Enable Line-Fault Test" at address 1423.
***If "Enable Global Ambush Code" in Address 1422 is selected, then pro-
gram the 2-digit "Global Ambush Code" in Address 2045. If Address
2045 is left blank (•), then, the 2-digit "Global Ambush Code" will be "99".
****If this feature is not selected, the E15 Lug will, by default, activate
when the system is armed (all areas).
††For reference only and cannot be changed.
§This feature must be programmed in Fire Alarm applications.
1420 System Options
1421
Default
Option
Default
Option
OFF
1
Opening Report Only after Alarm Report
OFF
1
Auto Bell Test on Arming
OFF
2
Closing Report Only on Conditional Close
OFF
2
Auto Reset after Burglary Output Timeout
OFF
3
Incl. Sel./Grp. Bypass in Cond. Close /Status
OFF
3
Suppress Bypass Reminder when Armed
OFF
4
Status Report
OFF
4
Enable Local Alarm on First Zone AND Trip
5
RESERVED
OFF
5
Access Control on PGM2 Output
OFF
6
Enable AutoArm if not closed at end of Window OFF
6
Maintained Keyswitch Arming
OFF
7
Enable Keypad Time/Date Display
OFF
7
Enable Manager's Mode
OFF
8
Disable Zone Fault Scrolling
OFF
8
Disable Keypad Instant Mode
System Options
1422 System Options
1423 System Options
Default
Option
Default*
Option
OFF
1
Interior Normally Bypassed
OFF*
1
Enable Zone Doubling (Zones 9-12)
OFF
2
Enable Global Ambush Code ***
OFF*
2
Wireless Trouble Activates Telco 1
OFF
3
Reset Day Zone with Arm/Disarm Only
OFF*
3
Wireless Trouble Activates Telco 3
OFF
4
Enable Residential Fire
OFF*
4
Enable Alarm Output on Telco Fail only when Armed
OFF
5
Disable Keypad Function Mode Download
OFF*
5
Line-Fault Test only when Armed**
OFF
6
Disable Callback Download
OFF*
6
Enable Line-Fault Test**
OFF
7
Chirp Output on Keyfob Arm/Disarm
OFF*
7
Inhibit System Trouble Audible at Keypad
OFF
8
Change Pulse Output to Temporal Output
§
OFF*
8
Select Alarm Output for Keyfob Chirp
2051 System Options
Default
Option
OFF
1
Enable Keypad Set Time/Date Message
OFF
2
Enable Cancel Report to Telco 3
OFF
3
Disable [ON/OFF] as Easy Exit
4
RESERVED
5
RESERVED
6
RESERVED
OFF
7
Disable System Trouble Audible Timeout
OFF
8
Enable "K Series" Style Keypads
††
1424
Default
Option
OFF
1
Automatic Interior Bypass/Easy Exit
2
RESERVED
3
RESERVED
OFF
4
Resound on Wireless Smoke Low Battery
OFF
5
Don't Clear PGM2 Output with Disarm
OFF
6
Disable 2nd Call Ans. Machine Override
ON
7
Enable Loop Supervision
OFF
8
Disable Code Required for Bypass (Enable EZ Bypass)
System Options
2053
Default
Option
OFF
1
Exit Time Restart
OFF
2
Sound Alarm On Exit Error
OFF
3
Rpt Exit Err/Recent Close
OFF
4
Enable CP-01 Limits
OFF
5
Digital Dialer Rpt Enter /Exit Test Mode
OFF
6
Disable Call Waiting on 1st Attempt
OFF
7
Enable Keypad 1 Only Programming
OFF
8
Enable CP-01 Egress Tones Only
System Options
2054
Default
Option
OFF
1
Enable TCP/IP Communications
ON
2
Enable EN501 User Code Access Level
3
RESERVED
ON
4
Enable Display Time On Blanked Keypads
ON
5
Enable EN501 Grade 3 Operation
6
RESERVED
ON
7
Enable 2-Count Swinger Shutdown
ON
8
Enable Keypad Blanking
System Options
2052 E15 Lug / System Options
Default
Option
1
RESERVED
2
RESERVED
OFF
3
Lug E15 Area 1 Armed Away Only****
OFF
4
PGM on RF Transmitter Tamper
5
RESERVED
6
RESERVED
7
RESERVED
8
RESERVED
Содержание GEM-DXK1
Страница 56: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 56 LIB P432EX WIRING DIAGRAM...
Страница 57: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 57 LIB P432EXT WIRING DIAGRAM...
Страница 58: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 58 LIB P432EXT 230 WIRING DIAGRAM...
Страница 59: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 59 NOTES...