PROGRAM THE DATA ENTRIES
1. Enter the panel's Dealer Security Code, then press
w
.
2. Answer NO to all questions until "
ACTIVATE PROGRAM Y/N
" is displayed; then press YES ("
r
" or
p
).
NOTE:
If you pass "
ACTIVATE PROGRAM
", scroll backward using
x
.
3. Press
y
to enter the Address Program Mode. Address "
0000
" will display.
4. Press
0916
to access Address 0916.
The existing data will display and the cursor will ad-
vance to the data field.
5. Press
678
. The numbers 6,7 and 8 will appear on the keypad display indicating the zones acti-
vated.
6. Press
u
to save. Address 0916 is now programmed with "6,7,8".
7. Press
w
and enter another 4-digit address to continue programming --or-- press
y
to exit and resume
normal keypad operation.
B) Decimal Format
Settings (such as Entry and Exit Delay) display and accept data in decimal format, as a 3 digit number. Data is en-
tered directly, by pressing keys 0 – 9, with the cursor automatically moving to the right upon each key press.
EXAMPLE: DECIMAL Format with the GEM-DXRP1/DXK1:
Program
Abort Delay
to be 15 seconds.
DETERMINE THE DATA ENTRIES
1. Referring to SYSTEM DELAYS & TIMEOUTS in the Programming Worksheets that follow, the Abort Delay is
located at address 1417:
PROGRAM THE DATA ENTRIES
1. Enter the panel's Dealer Security Code, then press
w
.
2. Answer NO ("
X
" or
q
) to all questions until "
ACTIVATE PROGRAM Y/N
" is displayed; then press YES ("
r
" or
p
).
NOTE:
If you pass "
ACTIVATE PROGRAM
", scroll backward using
x
.
3. Press
y
to enter the Address Program Mode. Address "
0000
" will display.
4. Press
1417
to access Address 1417.
The existing data will display and the cursor will ad-
1417 - - - D
1417 015 D
ZONES 1 8
ZONES 9 16
ZONE FEATURES
ADDR Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 ADDR Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Exit/Entry Follower
0916
6 7 8
0911
DATA ENTRY LOCATION:
Decimal Format
•
No time yet entered
Address
1417
"Abort
Delay"
DATA ENTRY LOCATION:
Decimal Format
Press
015
in order to set
"Abort Delay" to 15 seconds. The "D" on the
right indicates "Decimal" format.
ABORT
ADDRESS 1417
DELAY
(sec.)
[Default = 0 sec. = blank (•)]
Address
1417
"Abort
Delay"
Содержание GEM-DXK1
Страница 56: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 56 LIB P432EX WIRING DIAGRAM...
Страница 57: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 57 LIB P432EXT WIRING DIAGRAM...
Страница 58: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 58 LIB P432EXT 230 WIRING DIAGRAM...
Страница 59: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 59 NOTES...