DIRECT ADDRESS OVERVIEW
Direct Address Programming allows you to go directly to the address locations (up to 2287) and change the data entries
manually in order to customize your control panel options. Whereas the Easy Menu Program Mode guides you through
limited selections to get you started,
Direct Address Program Mode
allows you to change all options directly. It con-
sists of up to 2287 address locations each with data entry locations as shown in the following diagram (below left). The
data entry location accepts data in one of three formats: Binary, Decimal and Hexadecimal (explained below in
"
Address Mode Displays
"). The following diagram (below right) illustrates a
Decimal
format data entry location (using
a GEM-DXRP1/GEM-DXK1 keypad).
ADDRESS MODE DISPLAYS
There are three types of address displays when programming in Direct Entry Program Mode, as follows:
A) Binary (Bit) Format
Settings (such as Zone Features) display and accept data in "number" format. For example, Zone Features are
turned on by the pressing of keypad buttons 1 through 8, with the activated Zone(s) displaying the corresponding
decimal digit (replacing deactivated zones which are signified by dashes).
EXAMPLE:
BIT Format with the GEM-DXRP1/DXK1:
Program Zones 2, 4, 5 and 7 as
Exit/Entry Follower Zones
.
DETERMINE THE DATA ENTRIES
1. Referring to ZONE FEATURES in the Programming Worksheets that follow, the Exit/Entry Follower for Zones 1
through 8 are located at address 0916.
DATA ENTRY
LOCATION
ADDRESS
LOCATIONS
0000
0000
TO
2287
DATA ENTRY LOCATION:
(One of three formats):
•
Binary (Bit)
•
Decimal
•
Hexadecimal
DIRECT ADDRESS PROGRAM MODE
GEM-DXRP1 / DXK1 Keypad Display Example
0 0 0 0 0 6 0
D
1
2
= ADDRESS LOCATION
1
2
= DATA ENTRY LOCATION
0916 - - - - - - - - B
0916 - 2 - 4 5 - 7 - B
DATA ENTRY LOCATION:
Binary (Bit) Format
•
No zones yet activated
Address
0916
"Exit/Entry
Follower"
Address
0916
"Exit/Entry
Follower"
DATA ENTRY LOCATION:
Binary (Bit) Format
Press
2
4
5
and
7
in order to acti-
vate Zones 2, 4, 5, and 7. (The "B" on the right indi-
cates "Binary" format). Because "bit numbers"
range from 0-7, these "option numbers" 2,4,5 and 7
correspond to "bit numbers" 1,3,4 and 6, respec-
tively.
Содержание GEM-DXK1
Страница 56: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 56 LIB P432EX WIRING DIAGRAM...
Страница 57: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 57 LIB P432EXT WIRING DIAGRAM...
Страница 58: ...LIBRA LIB P432EX Series Programming Instructions NAPCO Security Systems Page 58 LIB P432EXT 230 WIRING DIAGRAM...
Страница 59: ...NAPCO Security Systems LIBRA LIB P432EX Series Programming Instructions Page 59 NOTES...