© by N&W GLOBAL VENDING S.p.A.
36
11 2008 3275 00
gsm
gsm
piN
coDE
Function used to programme the identification code that
will be sent to the GSM modem (optional) as soon as
the machine is powered on.
gsm
prEalarms
Function used to define the number of pieces, after
which to signal an "ending product" prealarm via modem
and to reset the counters intended to manage prealarms.
b
aNK
NumbEr
The bank number (from 1 to 7) is intended to univocally
define the machines acting as a “GSM slave”, i.e. send
-
ing the data by means of the “master” machine modem.
0 is intended to identify the machine directly connected
with the modem, i.e. the “GsM master”, in a bank.
FAiLurES
this group of functions is intended to display and reset
the current failures and to display the history file of fail
-
ures.
FaIlUres
FaIlUre reaDoUt
FaIlUre reset
FaIlUre HIstorY FIle
tecH> x.x
the machine is equipped with several sensors intended
to control the various functional units.
as soon as a malfunction is found out, the type of failure
is displayed and the machine (or part of it) is set out of
order.
the failures are stored in special counters. the failures
managed by the software can be related to functional
units not available on a specific model. However, they
are listed on scrolling the menu.
f
ailurE
rEaDout
When the “Failures” function is displayed, press the en-
ter key
�
to display the current failures.
If there is no failure at the moment, press the enter key
�
to display the “Failure end” message.
expected failures are highlit in the following cases:
Compressor:
-
the machine stops if the compressor is
working for over twenty-four consecutive hours.
Probe:
-
the machine stops after 5 minutes if the inter-
nal temperature probe is interrupted. the display will
show -11°c. the machine stops after 1 hour if a probe
short-circuit is found out. In this case, the display will
show +41°c.
Coin mechanism:
-
the machine stops if it should
receive an over 2-sec. pulse on a validator line or if the
communication with the serial coin mechanism is not
longer than 30 (Executive protocol) or 75 (BDV proto
-
col) seconds.
rAm data:
-
one or more than one area of the raM
memory contain altered data that have been corrected
by default values.
the machine will continue to work, but it is recom-
mended to initialise as soon as possible.
Actuation board:
-
the machine stops if the cpU board
communication is interrupted.
motor error:
-
Use this function to display faulty motors
for about 1 second.
all faulty motors are scrolled automatically.
Note:
If you power on the machine again, any motor
that may have jammed is found out as not available.
Empty machine:
-
the machine stops if all machine
columns are empty.
f
ailurE
rEsEt
Confirm the function to reset all current failures, if any.
H
istory
filE
of
failurEs
Use this function to display the history file of failures. The
history file shows the failure with the corresponding date
and time.