© by N&W GLOBAL VENDING S.p.A.
17
11 2008 3275 00
c
olumN
DEptH
every single column, either single or double, is complete
with a back-column that can be moved by positioning the
support springs in the correct hole (see fig. 24).
to move the back-column, the column must be empty.
Press on the support springs (see fig. 24) to release the
back-column and reposition it to keep the vertical and
horizontal alignment.
the column shall be some millimetres deeper than the
addition of the product heights.
To measure the depth, use the frame edge (see fig. 25)
and the back-column as a reference.
add 18 mm to the addition of the product heights to get
the measurement.
For instance. to sell 250 cc cans that are 94 mm in
height, the distance between the frame edge and the
back-column shall be (94mm x 4 cans) +18mm = 394
mm.
After having reassembled the back-column, load
the column by following the first charge procedure.
Fig. 24
Back-column
1-
Support springs
2-
Spring fastening holes
3-
Fig. 25
Double column
1-
Single column
2-
Frame
3-
Back-column
4-
Содержание Diesis 500