iNSTALLATiON
installation and any subsequent maintenance
operation must be carried out when the machine
is live and, therefore, by the personnel skilled and
trained on the use of the machine as well as aware
of the specific risks such a condition may involve.
to power on the plant when the door is open, just insert
the key into the switch (see fig. 5).
The sales motors remain off thanks to the special
switch (see fig. 5) even if you have inserted the key.
this avoids the risk of accidental accidents.
To act on rotors electrically, close the door.
if the door is open, you can not access any live
part. Only the parts protected by covers and sig-
nalled by the plate "power off before removing the
cover" remain live inside the machine.
Before removing these covers, power off the exter
-
nal switch.
close the door only after having removed the key from
the door switch.
The machine must be installed in dry rooms at a
temperature between 2° and 34°C.
relative humidity shall not exceed 65%.
uNPACKiNg THE VENDiNg mACHiNE
after having unpacked the machine, make sure that the
equipment is intact.
In case of doubt never use the equipment.
No packing material (plastic bags, foam polysty
-
rene, nails, etc.) should be left within the reach of
children since they are potential sources of danger.
packing materials shall be disposed of in authorised
dump sites and recyclable ones collected by specialised
companies.
if the vending machine has been laid down during
transportation, wait at least an hour before con-
necting it with the power mains.
ASSEmBLiNg THE DiSPENSiNg
COmPArTmENT OuTLET POrT
When supplied, the dispensing compartment outlet port
is disassembled for passage between the doors.
the dispensing compartment outlet port must be as-
sembled outside the door and secured from the inside
by means of the screws supplied, as it is shown by the
figure.
In sequence:
open the machine door
-
couple the convex frame outside the door
-
Mount the stiffener on the dispensing outlet port
-
couple the cover of the dispensing outlet port
-
secure the dispensing compartment outlet port to
-
secure from the inside of the door by using the screws
supplied
Fig. 15
Dispensing outlet port
1-
Fastening screws
2-
Toothed washers
3-
Fastening nuts
4-
Convex frame
5-
Cover of the dispensing outlet port
6-
Outlet port stiffener