background image

© by N&W GLOBAL VENDING S.p.A. 

27

 

11 2008 3275 00

Exact

 

amouNt

” 

valuE

Used to define the combination of empty tubes intended 

to set the coin mechanism to the "exact amount" mode. 

all possible combinations of empty tubes are listed here 

below. 

For reasons of simplicity, the combination is described 

with reference to tubes a, B and c, where tube a will 

receive the lowest-value coins and tube c the highest-

value coins.

 

A or (B and C)

 

A and B and C

 

A and B only

 

A and (B or C)

 

A only

 

A or B only (default)

 

A or B or C

 

A or B only

 

A or C only

 

B and C only

 

10 

B only

 

11 

B or C only

 

12 

C only

D

ispENsiNg

 

buttoNs

Function used to enable or disable the buttons arranged 

on the coin mechanism in order to discharge the coins in 

the change tubes.

c.p.c. 

pEripHEral

 

uNit

It is intended to inform the coin mechanism whether 

some peripheral units have been installed or removed 

from the serial connection (peripheral units of the c.p.c 

type - the default control unit is always enabled).

m

iNimum

 

tubE

 

lEvEl

Used to warn the user in advance to "Insert exact 

amount" by adding a number of coins between 0 and 

15 to the number of coins that has been programmed to 

establish the status of full change tubes.

vmc 

frEE

 

salE

Most of the payment systems complete with a BDV pro-

tocol is intended to manage the free sale function.

However, there are some payment systems not having 

this function.

In this case, it is necessary to enable the VMc (vending 

machine control, disabled by default) free sale and to 

set the price of selections to zero if some selections are 

dispensed on a free basis.

mDb

The MDB protocol menus will enable the user to define 

the following functions.

i

mmEDiatE

 

cHaNgE

the amount relative to a selection is generally cashed 

after the machine has sent the "successful selection" 

signal.

If you enable this function, which is disabled by default, 

the cash signal is sent at the start of the dispensing 

cycle.

the setup of this parameter is compulsory.

D

Ecimal

 

poiNt

press the enter key 

 to display the position of the deci-

mal point, i.e.

decimal point disabled

XXX.X (one decimal digit after the point)

XX.XX (two decimal digits after the point)

X.XXX (three decimal digits after the point)

If you press the enter key  

, these values will flash on 

and off and they can be modified.

the setup of this parameter is compulsory.

t

ypE

 

of

 

DispENsiNg

 

cyclE

Used to set the operation mode by multiple or single 

dispensing. In case of multiple dispensing, the change 

is not automatically given at the end of a successful 

delivery, but the credit will remain available for further 

dispensing. If you press the coin return button (if the 

function is enabled), the remaining credit will be returned 

up to the maximum change value.

o

bligatioN

 

to

 

buy

to enable/disable the operation of the coin return button 

before dispensing a product. 

on: the change is returned after having selected a 

 -

product
oFF: the change is returned just after having pressed 

 -

the coin return key (the machine is acting as a coin 

changer)

m

aximum

 

crEDit

Function used to define the maximum accepted credit 

for inserted coins.

m

aximum

 

cHaNgE

You can set a limit on the total amount of the change 

the coin mechanism will pay as soon as you press the 

change button or after one single dispensing.

the credit exceeding the amount you have programmed 

by this function will be cashed.

Содержание Diesis 500

Страница 1: ...InstallaTion operation Maintenance EN English Diesis 500 700 Doc No H 3275EN 00 Edition 1 11 2008...

Страница 2: ......

Страница 3: ...s sp cifications techniques d signations qui ont t appliqu es conform ment aux r gles de la bonne pratique en mati re de s curit en vigueur dans l UE sont Deutsch Die harmonisierten Standards oder tec...

Страница 4: ...children and by people having reduced physical sensorial or mental skills under the supervision of people responsible for their safety or specifically trained on the use of the machine Children shall...

Страница 5: ......

Страница 6: ......

Страница 7: ...egular intervals 11 cleaning the ventilation grid 11 service interruption 11 installation 12 unpacking the vending machine 12 assembling the dispensing compartment outlet port 12 payment system assemb...

Страница 8: ...ed by a specific serial number that can be found on the rating plate arranged inside on the right side The plate see figure is the only one recognised by the manufacturer and it contains all the data...

Страница 9: ...es to open the door properly It shall not be covered by a piece of cloth or alike The machine must be arranged in such a way that the maximum inclination will not exceed 2 If necessary level it by usi...

Страница 10: ...products The machine can be arranged to sell bottles between 62 and 73 mm in diameter and be tween 234 and 280 mm in height in single row bottles between 62 and 73 mm in diameter and be tween 196 and...

Страница 11: ...he electric energy consumption of the machine will depend upon many factors such as the temperature and ventilation of the room where the machine is installed the product load temperature and the temp...

Страница 12: ...faces even if not directly in contact with food stuffs Some parts of the machine can be damaged by corro sive detergents The manufacturer will disclaim all responsibility for any damage caused to peop...

Страница 13: ...machine door and the coin mechanism support by unscrewing the knurl Insert the plates into the slots and observe the order of products Keep in mind that the highest selection button corresponds to the...

Страница 14: ...dth For double columns rows must be alternatively loaded on the right and on the left see fig 8 Columns can be arranged to dispense cans 66 mm in diameter or round bottles from 62 to 73 mm in diameter...

Страница 15: ...s in a row above the rotor the bottles must be loaded after having turned the cap to the back column continue to load the next rows by alternating on the right and on the left if the column is a doubl...

Страница 16: ...mperature value inside the machine during its normal operation directly in C from 4 5 C to 20 C 4 5 C by default The temperature will be lower at the bottom of the refrigerated box including the bottl...

Страница 17: ...rator or the condenser Avoid placing any product in the area round the evapora tor because this might hinder the cold air flow that shall be able to circulate freely Otherwise ice might build up on th...

Страница 18: ...aving unpacked the machine make sure that the equipment is intact In case of doubt never use the equipment No packing material plastic bags foam polysty rene nails etc should be left within the reach...

Страница 19: ...ec ommended for the connection points the main switch shall be featured in such a way that it can support the maximum load required and to ensure omnipolar disconnection from the mains with an open in...

Страница 20: ...ing to the type of bottle Glass bottles can be dispensed in single columns only To enable a column to dispense a well defined product check the type and position of the following parts rotor insert an...

Страница 21: ...le the new shim into the slots at the right end of the column Number of rows For bottles from 234 to 285 mm in height you can ar range the column for dispensing in single row only Bottles between 196...

Страница 22: ...es and the number of rows as it is specified by fig 24 by using the slots on the deflector The following table is intended to sum up the variables relative to the number of rows per column Anti fricti...

Страница 23: ...umn shall be some millimetres deeper than the addition of the product heights To measure the depth use the frame edge see fig 25 and the back column as a reference Add 18 mm to the addition of the pro...

Страница 24: ...uitable shim and to regulate the guides correspondingly Anti friction elements shall be assembled between the bottle guides The two guides are placed at a correct distance when bottles move down as fa...

Страница 25: ...sembly Unscrew the safety screws and remove the door After having accessed the room reassemble the door by acting in the reverse order INTERNAL componentS The evaporator unit on the shelf of the refri...

Страница 26: ...and all checks are performed Operations that can be carried out when the door is closed The selection is dispensed and messages are dis played for the user Filler menu Statistical findings and executi...

Страница 27: ...ptance dispensing selections Filler menu test dispensing cycles machine maintenance Technician menu programming parameters The display and keyboard functions vary according to the operation mode as it...

Страница 28: ...or some seconds and the machine will get ready for another delivery SERVE YOURSELF If the control system should find out a failure an error message will appear and specify the type of problem SELECTIO...

Страница 29: ...name software release operator code machine code installation date To print act as follows from the print function press the Enter key to display Do you confirm connect the printer before confirming...

Страница 30: ...ice of the second selection if the second dispensing cycle of a virtual selection should fail only if MDB payment systems or validators are in use For the other payment systems you can establish wheth...

Страница 31: ...de available The last line shows the menu and the number enabling the operator to find out the level you are in Press the Enter key to access the menu Press the Exit key to go back to the previous men...

Страница 32: ...ed among those recognised by the validator For the coin value correspondence check the label showing the position of the coins on the coin mecha nism Coins not accepted Used to program the refusal of...

Страница 33: ...free basis MDB The MDB protocol menus will enable the user to define the following functions Immediate change The amount relative to a selection is generally cashed after the machine has sent the Succ...

Страница 34: ...ns have oc curred by means of a cashless system The values available are listed here below 0 standard operation cash transactions are recorded as such 1 forced sending to cashless 1 cash transactions...

Страница 35: ...a promotional price list if the time band is enabled by the corresponding function Selections will be dispensed at the price of the promo tional list during the time intervals you have programmed mdb...

Страница 36: ...parameters of selections with respect to factory settings Restore modified DB To restore the machine configuration you have custom ised and saved before by means of the Save modified DB function To r...

Страница 37: ...le spiral a 4 digit identification code to process statistics Energy saving This function is disabled by default Use it to stop selling at well defined time intervals 2 time bands for service interrup...

Страница 38: ...nes 0 by default Site code Use this function to store a code associated with the installation site of the machine Installation date Use this function to store the installation date of the machine Test...

Страница 39: ...n be configured Pass code It is a 4 digit alphanumeric code 0 9 A F that must be the same as the one of the data transfer terminal for identification purposes Setup by default 0000 Security code It is...

Страница 40: ...o printed Statistics can be printed either partially or totally To connect the printer act as follows press the Enter key to display the request for confir mation Do you confirm connect the printer be...

Страница 41: ...munication with the UpKey and GSM Global System for Mobile communications systems Upkey setup management upkey vending machine After having inserted the Up key into the plug on the C P U board this fu...

Страница 42: ...key to display the current failures If there is no failure at the moment press the Enter key to display the Failure end message Expected failures are highlit in the following cases Compressor The mac...

Страница 43: ...iance with the rules of the relative installations shall be checked by skilled personnel at least once a year FunCTIONS AND ARRANGEMENT OF BOARDS Actuation board This board see fig 31 and 32 is intend...

Страница 44: ...any reason whatsoever SOftware UPDATE The machine is equipped with Flash EPROM s that can be electrically rewritten Use a proper program and system personal Computer Up Keys or alike to rewrite the m...

Страница 45: ...id any negative consequence for the environment and human health lamps shall be properly disposed of ELECTRIC PANEL The electric panel is accommodated in the compartment beneath the refrigerated box F...

Страница 46: ...on Enter key to move to the lower level or to confirm a data item you have just en tered or modified Exit key Press the Exit key to move back to the upper level or to quit a field intended to modify a...

Страница 47: ...2 TOTAL PRINTING 1 2 PRINT REL STATS 1 2 1 PARTIAL PRINTING 1 2 1 1 SELECT COUNT 1 2 1 2 BAND COUNTER 1 2 1 3 FAILURE COUNT 1 2 1 4 COIN MECH DATA 1 2 2 TOTAL PRINTING 1 3 STATIST DISPLAY 1 3 1 SEL CO...

Страница 48: ...value 1 DIRECT PRICE ProgrammING filler menu summary 1 5 CANC RELAT STATS 1 5 1 PARTIAL RESET 1 5 1 1 SELE COUNT RESET 1 5 1 2 FAILURE COUNT 1 5 1 3 COIN MECH DATA 1 5 2 TOTAL RESET 2 INDIVIDUAL PRICE...

Страница 49: ...ME BAND 2 2 3 3 TIME BAND 3 2 3 4 TIME BAND 4 3 DA CONFIGURATION 3 1 SET DATE TIME 3 2 COLD UNIT 3 3 DB MANAGEMENT 3 3 1 INITIALISING DB 3 4 DISPLAY 3 4 1 LANGUAGE 3 4 2 SECOND LANGUAGE 3 4 3 USER DIS...

Страница 50: ...4 CHANGE IMMEDIAT 3 D 5 NEW ZETA TYPE 4 TEST 4 1 TEST SELECTION 4 2 AUTOTEST 4 3 EMPTY COLUMN 5 STATISTICS 5 1 EVADTS 5 1 1 PROTOC COMUNICAZ 5 1 2 MODE 5 1 3 BAUDRATE 5 1 4 CONNECTION 5 2 STATIST DISP...

Страница 51: ...OUNT 5 4 3 FAILURE COUNT 5 4 4 COIN MECH DISPL 5 4 4 1 AUDIT DATA DISP 5 4 4 2 CASH COUNT DISP 5 5 CANC RELAT STATS 5 5 1 PARTIAL RESET 5 5 1 1 SELE COUNT RESET 5 5 1 2 FAILURE COUNT 5 5 1 3 COIN MECH...

Страница 52: ...T PRICE ProgrammING by N W GLOBAL VENDING S p A 46 06 2010 3275 00 technician menu summary 6 COMMUNICATION 6 1 UPKEY 6 1 1 UPKEY MACHINE 6 1 2 MACHINE UPKEY 6 1 3 DELETE 6 1 4 DELETE ALL 6 2 AUDIT MAN...

Страница 53: ...________________ ________________________________________________ ________________________________________________ ________________________________________________ ____________________________________...

Страница 54: ...or one of its subsidiaries without whose permission it may not be copiedor discosed to third parties of otherwise used This drawing has to be returned promptly upon request to N W 6 9 8 7 5 4 3 2 1 0...

Страница 55: ...14 J2 15 J2 16 J1 2 J1 3 J6 9 8 7 J6 7 79 J6 6 82 J6 5 70 J6 4 86 J6 3 3 J6 2 90 J6 1 24 9 J7 2 J7 1 93 J8 2 90 J8 1 2 J8 3 MDS 7 7 3 J5 1 J5 2 11 10 9 8 7 6 5 4 3 2 1 71 70 80 28 60 96 10 2 91 3 J9...

Страница 56: ...s MDB MDB COIN MECH CONNECTOR SX 6085 472 01 This drawing contains confidential information and is the property of the holding company of N W or one of its subsidiaries without whose permission it may...

Страница 57: ...RS232 SERIAL PORT SUC C P U BOARD P1 SELECTION BUTTONS PIP PROGRAMMING BUTTON SCHEMA ELETTRICO WIRING DIAGRAM PORTA DOOR Diesis...

Страница 58: ...________________ ________________________________________________ ________________________________________________ ________________________________________________ ____________________________________...

Страница 59: ...ll responsibility for any inaccuracy contained in this publication that can be ascribed to printing and or transcription errors All instructions drawings tables and information in general contained in...

Страница 60: ......

Отзывы: