GT10/GT30
9.3 Error Codes and How to Handle Them
142
9.3
Error Codes and How to Handle Them
When an error occurs in the GT series, an error code displays at the top right of the
screen. There are two types of error codes:
GT series error codes
PLC error codes
ER XX
Error code display
9.3.1
GT Series Error Codes
When connected to a FP series PLC
The following three types of error codes are displayed when there is an error in the GT
main unit:
Code no.
Content
Cause and solution
FF
Time up error
No response from the PLC.
1) The PLC connection cable is disconnected. Check the connection
cable to make sure it is connected.
2) There is a temporary error due to noise, etc. Re–supply power to the
PLC and GT main unit.
21
Data error
A data error occurred dur-
ing communication.
1) An error exists in the communication condition settings. Check the
PLC and GT main unit communication speed and transfer format.
2) There is a temporary error due to noise, etc. Re–supply power to the
PLC and GT main unit.
22
Overrun error
The GT main unit cannot
receive data.
The reception buffer in the GT main unit is overflowing.
There could be an error in the PLC.
Re–supply power to the PLC and GT main unit.
When connected to a PLC (FX) series made by Mitsubishi Electric
The following four types of error codes are displayed when there is an error in the GT
main unit:
Code no.
Content
Cause and solution
FF
Time up error
No response from the PLC.
Check the connection cable to make sure it is connected.
10
Data error
A data error occurred dur-
ing communication.
Check to see if there is an error in the communication parameters
settings.
12
Overrun error
The GT main unit cannot
receive data.
The problem may be caused by a runaway PLC.
61
PLC error
A NAK error has been re-
turned by the PLC.
Check the PLC settings.
Содержание GT10
Страница 9: ...Table of Contents GT10 GT30 viii...
Страница 10: ...ix Part I GT10 GT30 Main Unit...
Страница 23: ...Safety Precautions GT10 GT30 xxii...
Страница 24: ...Chapter 1 Specifications...
Страница 37: ...GT10 GT30 1 5 Dimensions 14...
Страница 38: ...Chapter 2 Installation and Wiring...
Страница 48: ...Chapter 3 Setup...
Страница 63: ...GT10 GT30 3 4 Setting the Basic Communication Area GT30 and PLC 40...
Страница 64: ...Chapter 4 Connecting and Communicating with the PLC...
Страница 84: ...GT10 GT30 4 10 Through Function 61 FP Programmer II on an ongoing basis GT10 GT30 FP Programmer II 25V DC max...
Страница 94: ...Chapter 5 GT10 Configuration Settings...
Страница 115: ...GT10 GT30 5 3 Entering Configuration Settings from the GT10 92...
Страница 116: ...Chapter 6 GT30 Configuration Settings...
Страница 138: ...Chapter 7 How the Various Functions Are Used...
Страница 149: ...GT10 GT30 7 3 GT30 Bit Device Functions 126...
Страница 150: ...Chapter 8 Servicing and Maintenance...
Страница 157: ...GT10 GT30 8 5 Replacing the Backlight GT30 Only 134...
Страница 158: ...Chapter 9 Troubleshooting...
Страница 170: ...147 Matsushita Electric Works Europe AG Part II Screen Creation Tool Terminal GTWIN...
Страница 174: ...Chapter 10 Preparing GTWIN...
Страница 187: ...GT10 GT30 10 4 Procedures for Using GTWIN 164...
Страница 188: ...Appendix A Code Tables...
Страница 191: ...GT10 GT30 A 2 ASCII Code Table 168...