Screen Display
3-6
(00400)
LED
LED Status
Operation
A
CFast
Lit Red
In accessing
Off
Cards not set at Cardslot properly / Failed in access / No
power
-
ETHERNET
Lit Orange
1000BASE-T network communication
-
Flashing Green
100BASE-TX network communication
-
Off
No network connection
-
CAM MODE
Lit Blue
STOP mode, PLAY mode, LOOP mode,
SAVE mode, EXPORT mode (Downloading by HXLink etc.)
White (Flashing)
VIEW mode (Flashing with EST synchronized settings)
Purple (Magenta)
(Flashing)
ARM mode (Flashing with EST synchronized settings)
Orange (Flashing)
REC mode (Flashing with EST synchronized settings)
Off
Power OFF
-
PWR STS
Lit Green
Power ON, normal status (no warning display)
Lit Red
Power ON, fail status (warning display)
Off
Power OFF
-
MEM BACKUP
Lit Green
Memory backup is valid by AC adapter (Charge: High)
Flashing Green
Memory backup is valid by built-in battery only (Charge:
High)
Lit Orange
Memory backup is valid by AC adapter (Charge: Medium)
Flashing Orange
Memory backup is valid by built-in battery only (Charge:
Medium)
Lit Red
Memory backup is valid by AC adapter (Charge: Low)
Flashing Red
Memory backup is valid by built-in battery only (Charge:
Low)
Off
Memory backup is invalid
TRIGGER
Lit Red
After trigger input
Off
Before trigger input
LED indication fully relies on CFast card specification and therefore LED could not light
Содержание ST-839
Страница 2: ......
Страница 13: ...This Booklet This Booklet 11 00400 About the notation in the text A Indicates the page referenced ...
Страница 16: ...Table of Contents 14 00400 11 Index Index 11 2 ...
Страница 23: ...Exterior View and Names of Each Part 1 7 00400 1 Lens mount A 2 3 Front and Back 1 ...
Страница 35: ...Connecting the Camera and Cables 2 7 00400 Diagram of Input Output Connections on the Rear Panel ...
Страница 45: ...Turning the Power ON OFF 2 17 00400 6 Connect the cable to the HX 7 ...
Страница 56: ...J PAD3 Operation 3 10 00400 ...
Страница 90: ...Lens Control 3 44 00400 Hold switch Temporarily disables operation from the J PAD3 ...
Страница 98: ...3 52 00400 ...
Страница 188: ...5 16 00400 ...
Страница 202: ...6 14 00400 ...
Страница 220: ...7 18 00400 ...
Страница 318: ...9 66 00400 ...
Страница 360: ...Figures Figures 10 42 00400 MEMRECAM HX 7 Camera Unit Dimensional Figure ...
Страница 361: ...Figures 10 43 00400 AC Adapter Dimensional Figure ...
Страница 362: ...10 44 00400 ...
Страница 363: ...11 1 00400 11 Index Index 11 2 ...
Страница 370: ...Index 11 8 00400 Y YC TIFF 7 14 Z ZOOM 5 4 6 5 ...