![Murr Elektronik Data Panel xtreme DB DP-34044-1 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/murr-elektronik/data-panel-xtreme-db-dp-34044-1/data-panel-xtreme-db-dp-34044-1_user-manual_1858234051.webp)
A Murrelektronik Company
A Murrelektronik Company
51
Status Message 3 (Controller Information)
PGN
65523 (0xFFF3)
Source Address
224 (0xE0)
PDU Format
255 (0xFF)
PDU Specific
243 (0xF3)
Built Message
(0x
18FFF3E0
)
Status Message 4 (Output Amperage Feedback OUT 1A-2B)
Name
Data Type
Byte
Bits
Description
OUT 1A AMP FEEDBACK
Word
1
Current reading on Output 1A, 0-4,000 = 0-4000 mA
2
OUT 1B AMP FEEDBACK
Word
3
Current reading on Output 1B, 0-4,000 = 0-4000 mA
4
OUT 2A AMP FEEDBACK
Word
5
Current reading on Output 2A, 0-4,000 = 0-4000 mA
6
OUT 2B AMP FEEDBACK
Word
7
Current reading on Output 2B, 0-4,000 = 0-4000 mA
8
PGN
65524 (0xFFF4)
Source Address
224 (0xE0)
PDU Format
255 (0xFF)
PDU Specific
243 (0xF4)
Built Message
(0x
18FFF4E0
)
Status Message 5 (Output Amperage Feedback OUT 3A-4B)
Name
Data Type
Byte
Bits
Description
OUT 3A AMP FEEDBACK
Word
1
Current reading on Output 3A, 0-4,000 = 0-4000 mA
2
OUT 3B AMP FEEDBACK
Word
3
Current reading on Output 3B, 0-4,000 = 0-4000 mA
4
OUT 4A AMP FEEDBACK
Word
5
Current reading on Output 4A, 0-4,000 = 0-4000 mA
6
OUT 4B AMP FEEDBACK
Word
7
Current reading on Output 4B, 0-4,000 = 0-4000 mA
8
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
Name
Data Type
Byte
Bits
Description
CNFG1
Byte
1
All
Hardware Configuration
CNFG2
2
PCB Assembly Revision
VBAT
10 Bit
3
Battery Voltage
4
1, 2
TEMP
12 Bit
5
All
Module Temperature
6
1, 2, 3, 3
CNFG3
Byte
7
All
Additional Configuration
8
Not Used
PGN
65532 (0xFFFC)
Source Address
224 (0xE0)
PDU Format
255 (0xFF)
PDU Specific
252 (0xFC)
Built Message
(0x
18FFFCE0
)
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0