26
B. Individual Configuration
Individual input configuration is done through the “input mode” nibble in PGN 61408
Name
Data Type
Byte
Bits
Description
Command
Byte
1
Command for index pointer (which message you’re sending)
OUTMODE1A
4 bit
2
1,2,3,4
Mode 0x0=disabled, 0x1=On/Off, 0x2=Data(0-4000), 0x3=Percent(0-1000 = 0-100.0%),
0x4=Amps(0-4000 = 0-4.000A)
OUTMODE1B
5,6,7,8
OUTMODE2A
3
1,2,3,4
OUTMODE2B
5,6,7,8
OUTMODE3A
4
1,2,3,4
OUTMODE3B
5,6,7,8
OUTMODE4A
5
1,2,3,4
OUTMODE4B
5,6,7,8
INMODE5A
4 bit
6
1,2,3,4
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground
INMODE5B
5,6,7,8
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground, 0x3= 4-20ma (4000-20000),
0x4= 0-5V DC (0-5000, 0x5= 0-10V DC (0-10000), 0x6= 0-32V DC(0-32000),
0x9= Ratiometric (0-100.0% of source V DC)
INMODE6A
7
1,2,3,4
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground
INMODE6B
5,6,7,8
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground, 0x3= 4-20ma (4000-20000),
0x4= 0-5V DC (0-5000, 0x5= 0-10vdc (0-10000), 0x6= 0-32V DC(0-32000),
0x9= Ratiometric (0-100.0% of source V DC)
INMODE7A
8
1,2,3,4
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground, 0x7=Digital Positive Frequency,
0x8=Counter, 0xA=Encoder
INMODE7B
5,6,7,8
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground, 0x3= 4-20ma (4000-20000),
0x4= 0-5V DC (0-5000, 0x5= 0-10vdc (0-10000), 0x6= 0-32V DC(0-32000),
0x9= Ratiometric (0-100.0% of source V DC)
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
Command Value
83 (0x53h)
PGN
61408 (0xEFE0) Node offset of 0
Source Address
(0x?? (CSA*))
PDU Format
239 (0xEF)
PDU Specific
224 (0xE0)
Built Message
(0x
18EFE0??
)
INMODE: See 5.3.3 C for settings