Innovation. Quality. Performance. Best in Industry. Worldwide.
Installation Checklist
These machine installation procedures should be followed in order by a
MultiCam
Technician, and the CNC
machine should be fully functional at the end of the installation. Three asterisks (***) indicate optional steps that
may not be applicable to all CNC machines.
Receiving Preparation
1. Machine unpacked & inventoried (suggest
customer take digital pictures)
6. Ethernet communication cable run
2. Shipping damage claimed & replacement
parts ordered if any
7. Air pressure to machine must be checked.
Incoming Air Pressure ______________
3. Machine & fume extraction units in final
location w/proper space requirements
8. Fume extraction provided ***
4. Leveling feet on
9. Computer provided
5. Proper electrical to disconnect switch from
disconnect box on machine, fume
extraction unit, & auxiliary units
10. Process gases, consumables, &
materials for training with & 3/8 airline
hoses
Mechanical Installation: PHASE I
1. Level table (as low as possible).
5.
Re-adjust belts (if necessary).
2. Remove all axis covers.
6. Install the pendant to the control box.
3. Reseat the X-axis motor assemblies in the rack.
7. Slightly loosen the bolts connecting the
X castings to the gantry.
4. Connect the motor connectors for XA, XB, Y,
and Z to the control box.
Electrical Installation
Make sure the voltage setting is close to 40Vdc without going over.
1. Measure the incoming voltage at C/B with
wires 100/L1 and 102/L3.
6. Check the AC voltage at pins 23 & 24 for
approximately 26-28Vac for MD4 and
approximately 53-55Vac for HP4. If the
level is too high, power down to adjust
the transformer.
2. Adjust the transformer with the power OFF.
Move wire 112 to matching incoming voltage
at locations 210, 220, 230, or 240.
7. Power down and attach. Connector N
back to the controller box.
3. Check for loose/disconnected wires (including
gantry head and spindle box) with the power
OFF.
8. Power up the machine.
4. Disconnect the Connector N from the top of the
silver controller box inside the cabinet with the
power OFF.
9. Adjust the transformer and try again if
the voltage is too high and an error
message shows on the keypad.
5. Turn the circuit breaker ON and OFF.
10. Check the voltage at the keypad by
pressing
Shift
,
Help
, and
Six
. Refer to
the Schematics and adjust the
transformer if necessary.
Routers * Lasers * Plasma * WaterJets * Knife Cutters
www.MultiCam.com