2019 Premium Concept Elite Service Manual
Visit our website at: www.the-mspa.com
- 16 -
Chapter 4 How to Replace Mspa Parts
4.1 Power Board Assembly and Wire Terminal
Connection
Elite series with JET brown cable and jet blue cable connected
Premium series without JET brown cable and jet blue cable due to no Jet
function
The other wire connections are the same for Elite and Premium series
JET
blue
cable
Heating loop
black line
Blue
power
supply
BUBBLE
Brown
cable
Transformer
Brown
cable
Brown
power
supply
JET
Brown cable
flow switch
insert
(
big
)
Temperature
sensor insert
(small)
four-core
data cable
flow switch
insert
(
big
)
microswitch
insert
O3
generator
Brown
cable
Transformer
blue cable
O3 Generator blue cable
BUBBLEblue cable
Heating double circuit
connection (white)