Appendix: Optional Internal Relays and RESET Button
MSA
ULTIMA X ® Series
GB
93
Permissible Cable Length for the ULTIMA X
®
Series with Internal Relays
[4-20 mA models]
The permissible cable length varies for models with or without internal relays.
Specifications for Relays in the ULTIMA X
®
Series Gas Monitor with Internal
Relays
Sensor type
Supply
voltage
Wire cross-
section
Max. cable
length
Max. load resist-
ance [mA output]
Combustible
gases, catalytic
24 V DC
1.5 mm
2
800 m
500 Ohm
Combustible
gases, IR
24 V DC
1.5 mm
2
500 m
500 Ohm
Toxic gases and
oxygen
24 V DC
1.5 mm
2
2000 m
500 Ohm
Screened cable is recommended for the installation.
Temperature range
-40 °C to +60 °C
Humidity
15 % to 95 % RH non-condensing
Relays
3 alarms
SPDT [single pole, double throw]
Fault relay [normally ener-
gised]
SPDT [single pole, double throw]
Relay Ratings
At 125 V AC or 250 V AC,
non-inductive
5.0 A or 5 A at 75 W
At 30 V DC, non-inductive 5.0 A or 5 A at 75 W
Power consump-
tion [instrument
with relay]
Toxic gases and oxygen
At 24 V DC
max. 80 mA
Combustible gas, catalytic At 24 V DC
max. 200 mA
Combustible gas, IR
At 24 V DC
max. 250 mA
Содержание ULTIMA X-Series
Страница 1: ...Operating Manual ULTIMA X Series Gas Monitors Order No 10046690 09 ...
Страница 2: ...MSA AUER GmbH Thiemannstrasse 1 D 12059 Berlin Germany MSA AUER GmbH All rights reserved ...
Страница 28: ...MSA Description ULTIMA X Series 28 GB Fig 5 ULTIMA XA Fig 4 ULTIMA Remote sensor module non reactive gas ...
Страница 69: ...Appendix Electrical Installation MSA ULTIMA X Series GB 69 9 3 Installation Outline Drawing CE ULTIMA XA ...
Страница 72: ...MSA Appendix Electrical Installation ULTIMA X Series 72 GB 9 6 HART module M6 109 45 4 309 ...
Страница 158: ...MSA Appendix HART Specific Information ULTIMA X Series 158 GB Sensor Trim Point Screen Fig 52 Sensor trim point screen ...