MSA
Installation
ULTIMA X ® Series
30
GB
3.2
Installation with ULTIMA® X Series Mounting Kit
Instruments from the ULTIMA X
®
Series are installed at the place of installation on
a mounting plate.
Fig. 6
Mounting plate for ULTIMA XE and XIR
Mount the instrument as follows:
(1) Using the mounting plate as a template, mark the holes for the four fixing
screws.
(2) Drill four holes of appropriate diameter.
(3) Attach mounting plate to the Gas Monitor enclosure with M6 x 20 screws.
(4) Attach Gas Monitor with mounting plate, using four M6 x 20 screws, at the
place of installation.
1
Wall mounting fixing holes
2
Instrument fixing holes
1
1
2
Use M6 x 20 mm screws and suitable plugs for attaching the mounting
plate to the wall.
M6 x 20 screws will also be required for fixing the mounting plate to the
ULTIMA X Series enclosure.
When preparing the assembly, make sure that the mounting arrange-
ment is correct for the particular device.
Содержание ULTIMA X-Series
Страница 1: ...Operating Manual ULTIMA X Series Gas Monitors Order No 10046690 09 ...
Страница 2: ...MSA AUER GmbH Thiemannstrasse 1 D 12059 Berlin Germany MSA AUER GmbH All rights reserved ...
Страница 28: ...MSA Description ULTIMA X Series 28 GB Fig 5 ULTIMA XA Fig 4 ULTIMA Remote sensor module non reactive gas ...
Страница 69: ...Appendix Electrical Installation MSA ULTIMA X Series GB 69 9 3 Installation Outline Drawing CE ULTIMA XA ...
Страница 72: ...MSA Appendix Electrical Installation ULTIMA X Series 72 GB 9 6 HART module M6 109 45 4 309 ...
Страница 158: ...MSA Appendix HART Specific Information ULTIMA X Series 158 GB Sensor Trim Point Screen Fig 52 Sensor trim point screen ...