![MSA ULTIMA X-Series Скачать руководство пользователя страница 124](http://html.mh-extra.com/html/msa/ultima-x-series/ultima-x-series_operating-manual_1846483124.webp)
MSA
Appendix: HART Specific Information
ULTIMA X ® Series
124
GB
Command #186: Write Protect Mode
This command sends a single, unsigned byte to the device. Sending a 1 puts the
device in write protect mode. In write protect mode, all writes and commands are
ignored except a command to disable the write protect. Only reads to the device can
be made. Sending a disable, releases the device from write protect mode. During
write protect mode, all local [Pushbutton] controls are locked out as well.
Request Data Bytes
Response Data Bytes
Command-Specific Response Codes
Byte
Format
Description
0
Enum
Write protect Mode [0 = disable, 1 = Enable]
Byte
Format
Description
0
Enum
Write protect Mode [0 = disable, 1 = Enable]
Code
Class
Description
0
Success
No Command-Specific Errors
2
Error
Invalid Selection
3-4
Undefined
5
Error
Too few data bytes
6
Undefined
7
Error
In write protect mode
8-15
Undefined
16
Error
Access Restricted
17-31
Undefined
32
Error
Busy
33-127
Undefined
Содержание ULTIMA X-Series
Страница 1: ...Operating Manual ULTIMA X Series Gas Monitors Order No 10046690 09 ...
Страница 2: ...MSA AUER GmbH Thiemannstrasse 1 D 12059 Berlin Germany MSA AUER GmbH All rights reserved ...
Страница 28: ...MSA Description ULTIMA X Series 28 GB Fig 5 ULTIMA XA Fig 4 ULTIMA Remote sensor module non reactive gas ...
Страница 69: ...Appendix Electrical Installation MSA ULTIMA X Series GB 69 9 3 Installation Outline Drawing CE ULTIMA XA ...
Страница 72: ...MSA Appendix Electrical Installation ULTIMA X Series 72 GB 9 6 HART module M6 109 45 4 309 ...
Страница 158: ...MSA Appendix HART Specific Information ULTIMA X Series 158 GB Sensor Trim Point Screen Fig 52 Sensor trim point screen ...