73
Decommissioning
ALTAIR io360
US
9.2
HUB
WARNING!
• Do not connect or disconnect power and/or Ethernet connections to or from the HUB in a hazardous
location. Connect or disconnect only in a non-hazardous area.
• Do not remove, replace or disconnect the HUB while the circuit is live.
• Do not open the HUB when the power supply is energized.
• Do not substitute components. Substitution of components may impair intrinsic safety.
• Do not open the HUB in a hazardous location.
• Do not connect or disconnect Ethernet connection when the power supply is energized.
Failure to follow these warnings can expose a user to risk of electrical shock or ignition of explosive atmo-
spheres and can result in serious personal injury or death.
(1) Unplug the mains power supply.
(2) Power off the HUB.
(3) If present, unplug the Ethernet plug and install Ethernet plug.
(4) Loosen grounding clamp and remove grounding cable.
(5) Reattach grounding clamp.
(6) Open housing by opening the right joints and unscrew the lid screws
using a Torx T20.
(7) If needed, remove SIM card.
a) Open housing lid.
b) Remove SIM card.