Connecting analyser with MRU4win
The analyser is a Modbus device.
►
You can connect Modbus devices with MRU4win via a serial interface
(RS 485).
See also Chapter 14.4 RS485 Extern (Option), S.114.
►
You can connect Modbus devices to MRU4win via a TCP/IP
connection.
The TCP/IP connection can be made by LAN or WLAN.
Connecting analyser with MRU4win via serial interface (RS 485).
►
Connect the electrical connections of the RS485 interface as
described in Chapter 14.4 RS485 Extern (Option), S.114.
►
Connect the analyser to your PC via the RS485 interface.
►
Open the menu Device settings.
See also chapter 5.4 Device settings, Page 27.
►
Set "Modbus Slave ID" to 1.
Please note that the Modbus slave ID is a consecutive number.
If the number 1 is already assigned, assign "Modbus Slave ID" 2 etc. to
the analyser.
►
You can now create the analyser in MRU4win.
See also Chapter Creating analyser in MRU4win, Page 121.
Connecting analyser with MRU4win via TCP/IP connection
Before you can connect the analyser with MRU4win via a TCP/IP connec-
tion, you have to read out the IP address in the analyser.
►
Press the analyser to the network.
The connection can be made via LAN or WLAN.
See also Chapter 5.11 Connecting analyser with WIFI (WLAN), Page
43.
►
Press
the “Context menu” (19).