AirWorks AWK-3131A
Web Console Configuration
3-39
Cmd Port
Setting
Description
Factory Default
0 to 9999
This field specifies the TCP port number for listening to SSDK
commands from the host.
966
When the connection goes down
This field specifies what happens to the RTS signals when the Ethernet connection goes down. For some
applications, serial devices need to know the Ethernet link status through RTS signals sent through the serial
port.
Setting
Description
Factory Default
always low
The selected signal will change to low when the Ethernet
connection goes down.
always high
always high
The selected signal will remain high when the Ethernet
connection goes down.
Packet Length
Setting
Description
Factory Default
0 to 1024
This field specifies the maximum amount of data that is allowed
to accumulate in the serial port buffer before sending.
0: Packet length is disregarded and data in the buffer will be
sent as specified by the delimiter settings or when the buffer is
full.
1 to 1024: Data in the buffer will be sent as soon it reaches the
specified length.
0
Delimiter 1 and 2
Setting
Description
Factory Default
Enable
These fields are used to define special delimiter character(s) for
data packing. Enable Delimiter 1 to control data packing with a
single character; enable both Delimiter 1 and 2 to control data
packing with two characters received in sequence.
When these fields are enabled, serial data will accumulate in
the serial port’s buffer until the buffer is full or until the
specified delimiter character(s) are received. For example, the
carriage return character could be used as a delimiter in order
to transmit each sentence or paragraph in a separate packet.
Data will be packed according to Delimiter process.
Delimiters must be incorporated into the data stream at the
software or device level.
Unchecked
ATTENTION
When
Delimiter 1
is enabled,
Packet length
must be set to 0.
Delimiter Process
This field specifies how data is packed when delimiter characters are received. This field has no effect if
Delimiter 1 is not enabled.
Setting
Description
Factory Default
Do Nothing
Data accumulated in the serial port’s buffer will be packed,
including delimiters.
Do Nothing
Del 1
One additional character must be received before the data in
the serial port’s buffer is packed.
Del 2
Two additional characters must be received before the data in