AirWorks AWK-3131A
Getting Started
2-2
First-time Installation and Configuration
Before installing the AWK-1137C, make sure that all items in the Package Checklist are in the box. You will need
access to a notebook computer or PC equipped with an Ethernet port. The AWK-1137C has a default IP address
that must be used when connecting to the device for the first time.
•
Step 1: Connect a power source.
The AWK-1137C can be powered by a DC power input.
•
Step 2: Connect the AWK-1137C to a notebook or PC.
Since the AWK-1137C supports MDI/MDI-X auto-sensing, you can use either a straight-through cable or
crossover cable to connect the AWK-1137C to a computer. The LED indicator on the AWK-1137C’s LAN port
will light up when a connection is established.
•
Step 3: Set up the computer’s IP address.
Choose an IP address on the same subnet as the AWK-1137C. Since the AWK-1137C’s default IP address
is
192.168.127.253
, and the subnet mask is
255.255.255.0
, you should set the IP address of the
computer to
192.168.127.xxx
.
NOTE
After you select
Maintenance
Load Factory Default
and click the
Submit
button, the AWK-1137C will be
reset to factory default settings and the IP address will be reset to
192.168.127.253
.
•
Step 4: Use the web-based manager to configure the AWK-1137C
Open your computer’s web browser and type
http://192.168.127.253
in the address field to access the
homepage of the web-based Network Manager. Before the homepage opens, you will need to enter the
Username
and
Password
as shown in the following figure. For first-time configuration, enter the default
username and password and then click on the
Login
button.