AirWorks AWK-3131A
Web Console Configuration
3-46
Setting
Description
Factory Default
amount of time, the data that is currently in the buffer will be
packed for network transmission. The optimal force transmit
time depends on your application, but it must be at least larger
than one character interval within the specified baudrate. For
example, assume that the serial port is set to 1200 bps, 8 data
bits, 1 stop bit, and no parity. In this case, the total number of
bits needed to send a character is 10 bits, and the time required
to transfer one character is 8.3 ms, so the force transmit time
to be larger than 8.3 ms.
Communication Parameters
The
Communication Parameters
page for the serial port is where serial communication settings are
specified, such as
Baud rate
,
Data bits
, and
Stop bits
.
The
Communication Parameters
page for the serial port is where serial communication settings are
specified, such as
Baud rate
,
Data bits
, and
Stop bits
.
Port Alias
Setting
Description
Factory Default
free text (e.g.,
“Secondary console
connection”)
This is an optional free text field to help you differentiate one
serial port from another. It does not affect operation of the
AWK-1137C.
ATTENTION
Serial communication settings should match the attached serial device. Check the communication settings in
the user’s manual for your serial device.
Baud Rate
Setting
Description
Factory Default
75, 110, 134, 150, 300,
600, 1200, 1800, 2400,
4800, 7200, 9600,
19200, 38400, 57600,
This field specifies the baudrate for the serial port.
75 to 921600: The serial port will operate at the specified
baudrate.
115200