AirWorks AWK-3131A
Web Console Configuration
3-11
System Time
The AWK-1137C has a time calibration function based on information from an NTP server or user specified Date
and Time information. Functions such as
Logs and Notifications
can add real-time information to the
message.
The
Current local time
shows the AWK-1137C’s system time when you open this web page. You can click on
the
Set Time
button to activate the updated date and time parameters. An “(Updated)” string will appear to
indicate that the change is complete. Local system time will be immediately activated in the system without
running Save and Restart.
NOTE
The AWK-1137C has a built-in real time clock (RTC). We strongly recommend that users update the
Current
local time
for the AWK-1137C after the initial setup or a long-term shutdown, especially when the network
does not have an Internet connection for accessing the NTP server or there is no NTP server on the LAN.
Current local time
Setting
Description
Factory Default
User adjustable time
The date and time parameters allow configuration of the local
time, with immediate activation.
Use 24-hour format: yyyy/mm/dd hh:mm:ss
None
Time zone
Setting
Description
Factory Default
User selectable time
zone
The time zone setting allows conversion from GMT (Greenwich
Mean Time) to local time.
GMT (Greenwich
Mean Time)
ATTENTION
Changing the time zone will automatically adjust the
Current local time
. You should configure the
Time zone
before setting the
Current local time
.
Daylight saving time
Setting
Description
Factory Default
Enable/ Disable
Daylight saving time (DST or summer time) involves advancing
clocks (usually 1 hour) during the summer time to provide an
extra hour of daylight in the afternoon.
Disable
When
Daylight saving time
is enabled, the following parameters will be shown:
•
Starts at:
The date that daylight saving time begins.
•
Stops at:
The date that daylight saving time ends.
•
Time offset: